26 November 2021 in Ophthalmology Science
To assess the efficacy of an instrument-integrated OCT (iiOCT)-based distance sensor during robotic vitreoretinal surgery using the Preceyes Surgical System (PSS; Preceyes B.V.). Single-center interventional study. Patients requiring vitreoretinal surgery. Five patients were enrolled. Standard preoperative OCT images were obtained. After vitrectomy, a predefined set of actions was performed using the iiOCT-based sensor. Images then were processed to assess the signal-to-noise ratio (SNR) at various angles to the retina and at different distances between the instrument tip and the retinal surface. Preoperative and intraoperative OCT images were compared qualitatively and quantitatively. The feasibility in performing surgical tasks using the iiOCT-based sensor during vitreoretinal surgery, the SNR when imaging the retina, differences among intraoperative and preoperative OCT images, and characteristics of intraoperative retinal movements detected with the iiOCT-based probe. Surgeons were able to perform all the tasks but one. The PSS was able to maintain a fixed distance. The SNR of the iiOCT-based sensor signal was adequate to determine the distance to the retina and to control the PSS. Analysis of iiOCT-based sensor A-scans identified 3 clearly distinguishable retinal layers, including the inner retinal boundary and the interface at the retinal pigment epithelium–Bruch’s membrane. Thickness values differed by less than 5% from that measured by preoperative OCT, indicating its accuracy. The Fourier analysis of iiOCT-based sensor recordings identified anteroposterior retinal movements attributed to heartbeat and respiration. This iiOCT-based sensor was tested successfully and promises reliable use during robot-assisted surgery. An iiOCT-based sensor is a promising step toward OCT-guided robotic retinal surgery.
24 September 2022 in American Journal of Ophthalmology
7 October 2020 in Medical Engineering & Physics
Magnesium is an essential element for the ocular functions and used for the realization of medical devices due to its low corrosion resistance, bioresorbable nature and biocompatibility. Wet age-related macular degeneration is one of the main causes of blindness with patients treated by intravitreal injections of inhibitor drugs. According to the need to reduce the number of injections, the development of new drug delivery devices able to extend the therapeutical outcomes is mandatory and magnesium can be considered as a promising candidate. The aim of the work concerns the evaluation of the ocular fluid dynamic role on a magnesium-based device placed in the vitreous chamber. Particularly, the fluid-induced shear stress field on the surfaces in contact with the liquefied vitreous was studied. Both computational fluid dynamic and fluid-structure interaction approaches were proposed and then compared. Saccadic motion was implemented to recreate the vitreous fluid dynamics. High changes in terms of fluid-induced shear stress field varying the CFD and FSI numerical approaches and kinematic parameters of the saccadic function can be noticed. The comparison between CFD and FSI approaches showed minor significant differences and both implementations suggested the possibility to obtain a uniform and controlled corrosion of the device.
2 August 2021 in Canadian Journal of Ophthalmology
3 April 2025 in Biomedical Materials
The development of magnesium-based intraocular drug delivery devices holds significant promise for biomedical applications, particularly in treating wet age-related macular degeneration (AMD) using vascular endothelial growth factor inhibitors such as bevacizumab. Magnesium’s rapid degradation, which can be finely tuned to achieve the controlled release required for AMD treatment, along with its well-established biocompatibility and biodegradable properties, positioning it as an ideal material for these applications. The study aimed to evaluate magnesium’s potential as a carrier for ocular drug delivery systems by demontrating the stability of monoclonal antibodies, specifically bevacizumab, in the presence of magnesium corrosion products and the biocompatibility of these products with various cell lines, including murine fibroblasts (3T3), rat retinal Müller cells, and human retinal pigment epithelial cells (ARPE19). The stability of bevacizumab with pure magnesium (Mg) was investigated through an indirect enzyme-linked immunosorbent assay protocol, developed and customized for this specific aim. The biocompatibility of Mg corrosion products was assessed by toxicological evaluations through MTT and Trypan Blue Viability assays, along with cell cycle analysis. Results demonstrated no significant impact of Mg corrosion products on bevacizumab stability, with changes in mean values consistently below or equal to 10%. Furthermore, Mg extracts showed minimal cytotoxicity, as metabolic activity exceeded 80% across all cell lines, classified as Grade 0/1 cytotoxicity under ISO 10993-5 standards. Cell viability, proliferation, and morphology remained unaffected for up to 72 h of exposure. This study provides the first in vitro evaluation of bevacizumab’s stability in the presence of magnesium corrosion products and its biocompatibility with retinal cell lines, laying the foundation for future ophthalmic research and underscoring magnesium’s potential as a material for intraocular drug delivery systems.
20 November 2025 in RETINAL Cases & Brief Reports
Purpose: To present a case of suspected retinal phototoxicity after pars plana vitrectomy in a 45-year-old man undergoing Pre-Exposure Prophylaxis (PrEP) for HIV prevention. Methods: Retrospective case report. A 25-gauge pars plana vitrectomy was performed for vitreous hemorrhage and retinal breaks. Standard endo-illumination settings were used. No vital dyes were applied. Despite an initial uneventful surgery, a secondary retinal detachment required a subsequent vitrectomy with gas tamponade. Optical coherence tomography (OCT) and blue fundus autofluorescence were performed at each follow-up visit. Results: Postoperatively, OCT and blue fundus autofluorescence disclosed parafoveal disruption of the outer retinal layers, focal ellipsoid zone discontinuities, and retinal pigment epithelium (RPE) mottling within the illuminated area. At six months, best-corrected visual acuity improved to 20/25, although persistent RPE alterations were evident. Conclusion: The pattern of outer retinal changes suggests a photochemical injury potentiated by photosensitization from PrEP medication. Our findings underscore the need for new strategies to reduce light exposure during surgery in patients on systemic photosensitizing agents.