Pavlos Bobos

Dr. Pavlos Bobos

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2020 in Archives of Physical Medicine and Rehabilitation
Verified
Journal Article
Closed access
PBPavlos Bobos
Pavlos Bobos
GNGoris Nazari
Goris Nazari
ZLZe Lu
Ze Lu
JMJoy C. MacDermid
Joy C. MacDermid

8 May 2020 in Canadian Medical Association Journal
Verified
Journal Article
Open access
PDF file
PJPeter Jüni
Peter Jüni
MRMartina Rothenbühler
Martina Rothenbühler
PBPavlos Bobos
Pavlos Bobos
KTKevin E. Thorpe
Kevin E. Thorpe
BCBruno R. da Costa
Bruno R. da Costa
DGDionne Gesink
Dionne Gesink
Background: It is unclear whether seasonal changes, school closures or other public health interventions will result in a slowdown of the current coronavirus disease 2019 (COVID-19) pandemic. We aimed to determine whether epidemic growth is globally associated with climate or public health interventions intended to reduce transmission of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Methods: We performed a prospective cohort study of all 144 geopolitical areas worldwide (375 609 cases) with at least 10 COVID-19 cases and local transmission by Mar. 20, 2020, excluding China, South Korea, Iran and Italy. Using weighted random-effects regression, we determined the association between epidemic growth (expressed as ratios of rate ratios [RRR] comparing cumulative counts of COVID-19 cases on Mar. 27, 2020, with cumulative counts on Mar. 20, 2020) and latitude, temperature, humidity, school closures, restrictions of mass gatherings, and measures of social distancing during an exposure period 14 days previously (Mar. 7 to 13, 2020). Results: In univariate analyses, there were few or no associations of epidemic growth with latitude and temperature, but weak negative associations with relative humidity (RRR per 10% 0.91, 95% confidence interval [CI] 0.85–0.96) and absolute humidity (RRR per 5 g/m3 0.92, 95% CI 0.85–0.99). Strong associations were found for restrictions of mass gatherings (RRR 0.65, 95% CI 0.53–0.79), school closures (RRR 0.63, 95% CI 0.52–0.78) and measures of social distancing (RRR 0.62, 95% CI 0.45–0.85). In a multivariable model, there was a strong association with the number of implemented public health interventions (p for trend = 0.001), whereas the association with absolute humidity was no longer significant. Interpretation: Epidemic growth of COVID-19 was not associated with latitude and temperature, but may be associated weakly with relative or absolute humidity. Conversely, public health interventions were strongly associated with reduced epidemic growth.

21 February 2018 in BMC Sports Science, Medicine and Rehabilitation
Verified
Journal Article
Open access
PDF file
GNGoris Nazari
Goris Nazari
PBPavlos Bobos
Pavlos Bobos
JMJoy MacDermid
Joy MacDermid
KSKathryn E. Sinden
Kathryn E. Sinden
JRJulie Richardson
Julie Richardson
ATAda Tang
Ada Tang
Technological development and improvements in Wearable Physiological Monitoring devices, have facilitated the wireless and continuous field-based monitoring/capturing of physiologic measures in healthy, clinical or athletic populations. These devices have many applications for prevention and rehabilitation of musculoskeletal disorders, assuming reliable and valid data is collected. The purpose of this study was to appraise the quality and synthesize findings from published studies on psychometric properties of heart rate measurements taken with the Zephyr Bioharness device. We searched the Embase, Medline, PsycInfo, PuMed and Google Scholar databases to identify articles. Articles were appraised for quality using a structured clinical measurement specific appraisal tool. Two raters evaluated the quality and conducted data extraction. We extracted data on the reliability (intra-class correlation coefficients and standard error of measurement) and validity measures (Pearson/Spearman’s correlation coefficients) along with mean differences. Agreement parameters were summarised by the average biases and 95% limits of agreement. A total of ten studies were included: quality ratings ranged from 54 to 92%. The intra-class correlation coefficients reported ranged from 0.85–0.98. The construct validity coefficients compared against gold standard calibrations or other commercially used devices, ranged from 0.74–0.99 and 0.67–0.98 respectively. Zephyr Bioharness agreement error ranged from − 4.81 (under-estimation) to 3.00 (over-estimation) beats per minute, with varying 95% limits of agreement, when compared with gold standard measures. Good to excellent quality evidence from ten studies suggested that the Zephyr Bioharness device can provide reliable and valid measurements of heart rate across multiple contexts, and that it displayed good agreements vs. gold standard comparators – supporting criterion validity.

1 September 2020 in Journal of Orthopaedics
Verified
Journal Article
Closed access
PBPavlos Bobos
Pavlos Bobos
CZChristina Ziebart
Christina Ziebart
RFRochelle Furtado
Rochelle Furtado
ZLZe Lu
Ze Lu
JMJoy C. MacDermid
Joy C. MacDermid

1 October 2018 in Journal of Orthopaedic & Sports Physical Therapy
Verified
Journal Article
Closed access
PBPavlos Bobos
Pavlos Bobos
JMJoy C. MacDermid
Joy C. MacDermid
DWDavid M. Walton
David M. Walton
AGAnita Gross
Anita Gross
PSP. Lina Santaguida
P. Lina Santaguida
Background: The evaluation of patient-reported outcome measures for the neck from multiple systematic reviews will provide a broader view of, and may identify potential conflicting or consistent results for, their psychometric properties. Objectives: The purpose of this study was to conduct an overview of systematic reviews and synthesize evidence to establish the current state of knowledge on psychometric properties of patient-reported outcome measures for patients with neck disorders. Methods: In this overview of systematic reviews, an electronic search of 6 databases (MEDLINE, Embase, CINAHL, ILC, the Cochrane Central Register of Controlled Trials, and LILACS) was conducted to identify reviews that addressed at least one measurement property of outcome measures for people with neck pain. Only systematic reviews with patient-reported outcome measures were included in the analysis. Risk of bias was assessed with A MeaSurement Tool to Assess systematic Reviews (AMSTAR). Data on measurement properties were extracted from each systematic review. Results: From 13 systematic reviews, 8 patient-reported outcome measures were evaluated in 2 or more reviews. Risk-of-bias scores ranged from moderate (5–7) to high (4 and lower). Findings on internal consistency, test-retest reliability, construct validity, responsiveness to change, and content and structural validity were synthesized for the Neck Disability Index (NDI) in 11 systematic reviews; the Northwick Park Neck Pain Questionnaire and Neck Pain and Disability scale (NPDS) in 6 systematic reviews; the Copenhagen Neck Functional Disability Scale in 5 systematic reviews; the Neck Bournemouth Questionnaire in 4 systematic reviews; the Core Neck Pain Questionnaire and Patient-Specific Functional Scale in 3 systematic reviews, and the Whiplash Disability Questionnaire in 2 systematic reviews. Conclusion: High-quality evidence was found of good to excellent internal consistency and moderate to excellent test-retest reliability for the NDI. Moderate-quality evidence was found of good to excellent internal consistency and good test-retest reliability for the Northwick Park Neck Pain Questionnaire. High-quality evidence was found of excellent test-retest reliability and good to strong construct validity with pain scales for the Copenhagen Neck Functional Disability Scale. Moderate-quality evidence was found of unclear to excellent internal consistency and moderate to strong concurrent associations with the NDI and global assessment of change for the Neck Pain and Disability scale. Moderate-quality evidence was found of excellent internal consistency for the Whiplash Disability Questionnaire and of high test-retest reliability for the Patient-Specific Functional Scale. J Orthop Sports Phys Ther 2018;48(10):775–788. Epub 22 Jun 2018. doi:10.2519/jospt.2018.8131

25 November 2019 in BMJ Open
Verified
Journal Article
Open access
PBPavlos Bobos
Pavlos Bobos
JMJoy MacDermid
Joy MacDermid
GNGoris Nazari
Goris Nazari
RFRochelle Furtado
Rochelle Furtado
Objective: The purpose of this systematic review was to critically appraise and synthesise the psychometric properties of Global Rating of Change (GROC) scales for assessment of patients with neck pain. Design: Systematic review. Data sources: A search was performed in four databases (MEDLINE, EMBASE, CINAHL, SCOPUS) until February 2019. Data extraction and synthesis: Eligible articles were appraised using Consensus-based Standards for the selection of health Measurement Instruments checklist and the Quality Appraisal for Clinical Measurement Research Reports Evaluation Form. Results: The search obtained 16 eligible studies and included in total 1533 patients with neck pain. Test–retest reliability of global perceived effect (GPE) was very high (intraclass correlation coefficient=0.80 to 0.92) for patients with whiplash. Pooled data of Pearson’s r indicated that GROC scores were moderately correlated with neck disability change scores (0.53, 95% CI: 0.47 to 0.59). Pooled data of Spearman’s correlations indicated that GROC scores were moderately correlated with neck disability change scores (0.56, 95% CI: 0.41 to 0.68). Conclusions: This study found excellent quality evidence of very good-to-excellent test–retest reliability of GPE for patients with whiplash-associated disorders. Evidence from very good-to-excellent quality studies found that GROC scores are moderately correlated to an external criterion patient-reported outcome measure evaluated pre-post treatment in patients with neck pain. No studies were found that addressed the optimal form of GROC scales for patients with neck disorders or compared the GROC to other options for single-item global assessment. PROSPERO registration number: CRD42018117874.