Ghada M. Hammad

Mrs. Ghada M. Hammad

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 December 2020 in IEEE Access
Verified
Journal Article
Open access
DIDoaa Ibrahim
Doaa Ibrahim
GHGhada M. Hammad
Ghada M. Hammad
EZEssam Aboul Zahab
Essam Aboul Zahab
Ahmed F. ZobaaAhmed F. Zobaa
Ahmed F. Zobaa
This article extensively investigates the calculations of the compensation factor of the thyristor-controlled series compensator (TCSC), which are used to accurately evaluate the negative impacts of the TCSC on the performance of conventional distance relays. To broadly evaluate the distance protection performance, the TCSC was adapted to the IEEE 9-bus system as one of the interconnected transmission networks that are increasingly spreading to improve service reliability, reduce reserve capacity, and enhance system efficiency. In addition, IEEE 39-bus system, as a large interconnected system, is also examined to generalize the TCSC impact on different interconnected systems. To determine the precise impact, the impedance of the TCSC was calculated based on its practical design parameters. The impedance of the TCSC was examined as a function of transmission line impedance and firing angle. Both Mho and Quadrilateral distance relays were tested using the MATLAB/Simulink environment for different types of faults, fault locations, fault resistances, and firing angles for capacitive, inductive, and blocking modes of TCSC operation. In addition, distance relay performance was evaluated during power swing phenomenon in the presence of the TCSC. Simulation tests indicated the negative impacts of the TCSC on distance relay operation, which are not limited to over-reach and under-reach in faulty conditions but also to maloperation in dynamic disturbances that cause power swing phenomena on the protected line.

26 April 2021 in Energies
Verified
Journal Article
Open access
PDF file
GHGhada M. Hammad
Ghada M. Hammad
DIDoaa Ibrahim
Doaa Ibrahim
EZEssam Aboul Zahab
Essam Aboul Zahab
Ahmed F. ZobaaAhmed F. Zobaa
Ahmed F. Zobaa
This paper proposes an adaptive dynamic Mho distance relay based on a phase comparator scheme for protecting interconnected transmission networks compensated with a Thyristor Controlled Series Capacitor (TCSC). The proposed relay uses an impedance index factor to initiate the fault detection subroutine. The RMS of the positive sequence current of the faulted loop and the TCSC terminal current are compared for TCSC zone identification. A phase comparator for ground and phase distance elements is proposed, relying on the positive sequence voltage as a polarized memory quantity, while the operating and polarizing quantities are developed using estimated TCSC impedance to mitigate its negative impact. The proposed scheme is easy in implementation and independent on synchronized data transfer, as minimum communication requirements are needed. To evaluate the performance of the proposed scheme, extensive simulation studies were carried out on an IEEE9 bus system compensated with TCSC for different firing angles covering four modes of TCSC operations, different fault types, and fault locations. In addition, an IEEE-39 bus network, as a large interconnected system, is tested for validation purposes. The achieved results designate the precision of the proposed scheme. Moreover, the results indicate its effectiveness for fault resistance tolerance, close-in three phase faults, and stable power swing phenomenon compared with conventional relays.

28 October 2021 in Energies
Verified
Journal Article
Open access
PDF file
GHGhada M. Hammad
Ghada M. Hammad
DIDoaa Ibrahim
Doaa Ibrahim
EZEssam Aboul Zahab
Essam Aboul Zahab
Ahmed F. ZobaaAhmed F. Zobaa
Ahmed F. Zobaa
A two-fold adaptive dynamic quadrilateral relay is developed in this research for protecting Thyristor-Controlled Series Compensator (TCSC)-compensated transmission lines (TLs). By investigating a new tilt angle and modifying the Takagi method to recognize the fault zone identifier, the proposed relay adapts its reactive reach and resistive reach separately and independently. The investigated tilt angle and identified fault zone use the TCSC reactance to compensate its effect on the TL parameters and system homogeneity. Excessive tests are simulated by MATLAB on the non-homogenous network, IEEE-9 bus system and further tests are carried out on IEEE-39 bus system in order to generalize and validate the efficiency of the proposed approach. The designed trip boundaries are able to detect wide range of resistive faults under all TCSC modes of operations. The proposed approach is easy to implement as there no need for data synchronization or a high level of computation and filtration. Moreover, the proposed adaptive dynamic relay can be applied for non-homogeneity systems and short as well as long TLs which are either TCSC-compensated or -uncompensated TLs.