Essam Aboul Zahab

Prof. Dr. Essam Aboul Zahab

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 March 2024 in ISA Transactions
Verified
Journal Article
Closed access
ANAbdelhamid Nabeel
Abdelhamid Nabeel
ALAhmed Lasheen
Ahmed Lasheen
AEAbdel Latif Elshafei
Abdel Latif Elshafei
EZEssam Aboul Zahab
Essam Aboul Zahab

22 December 2020 in IEEE Access
Verified
Journal Article
Open access
DIDoaa Ibrahim
Doaa Ibrahim
GHGhada M. Hammad
Ghada M. Hammad
EZEssam Aboul Zahab
Essam Aboul Zahab
Ahmed F. ZobaaAhmed F. Zobaa
Ahmed F. Zobaa
This article extensively investigates the calculations of the compensation factor of the thyristor-controlled series compensator (TCSC), which are used to accurately evaluate the negative impacts of the TCSC on the performance of conventional distance relays. To broadly evaluate the distance protection performance, the TCSC was adapted to the IEEE 9-bus system as one of the interconnected transmission networks that are increasingly spreading to improve service reliability, reduce reserve capacity, and enhance system efficiency. In addition, IEEE 39-bus system, as a large interconnected system, is also examined to generalize the TCSC impact on different interconnected systems. To determine the precise impact, the impedance of the TCSC was calculated based on its practical design parameters. The impedance of the TCSC was examined as a function of transmission line impedance and firing angle. Both Mho and Quadrilateral distance relays were tested using the MATLAB/Simulink environment for different types of faults, fault locations, fault resistances, and firing angles for capacitive, inductive, and blocking modes of TCSC operation. In addition, distance relay performance was evaluated during power swing phenomenon in the presence of the TCSC. Simulation tests indicated the negative impacts of the TCSC on distance relay operation, which are not limited to over-reach and under-reach in faulty conditions but also to maloperation in dynamic disturbances that cause power swing phenomena on the protected line.

4 January 2023 in Systems
Verified
Journal Article
Open access
PDF file
MRMohamed M. Refaat
Mohamed M. Refaat
Shady Abdel AleemShady Abdel Aleem
Shady Abdel Aleem
YAYousry Atia
Yousry Atia
EZEssam Aboul Zahab
Essam Aboul Zahab
MSMahmoud M. Sayed
Mahmoud M. Sayed
Planning for the intensive use of renewable energy sources (RESs) has attracted wide attention to limit global warming and meet future load growth. Existing studies have shown that installing projects such as transmission lines, energy storage systems (ESSs), fault current limiters, and FACTs facilitate the integration of RESs into power systems. Different generation and transmission network expansion planning models have been developed in the literature; however, a planning model that manages multiple types of projects while maximizing the hosting capacity (HC) is not widely presented. In this paper, a novel planning framework is proposed to enhance and control the HC level of RESs by comparing various kinds of renewables, ESSs, fault current limiters, and FACTs to choose the right one, economically and technically. The proposed problem is formulated as a challenging mixed-integer non-linear optimization problem. To solve it, a solution methodology based on a developed decision-making approach and an improved meta-heuristic algorithm is developed. The decision-making approach aims to keep the number of decision variables as fixed as possible, regardless of the number of projects planned. While an improved war strategy optimizer that relies on the Runge-Kutta learning strategy is applied to strengthen the global search ability. The proposed decision-making approach depends primarily on grouping candidate projects that directly impact the same system state into four separate planning schemes. The first scheme relies on the impedance of devices installed in any path to optimally identify the location and size of the new circuits and the series-type FACTs. The second scheme is based on optimally determining the suitable types of ESSs. On the other hand, the third scheme optimizes the reactive power dispatched from the ESSs and shunt-type FACTs simultaneously. The fourth scheme is concerned with regulating the power dispatched from different types of RESs. All of the simulations, which were carried out on the Garver network and the 118-bus system, demonstrated the ability of the investigated model to select the appropriate projects precisely. Further, the results proved the robustness and effectiveness of the proposed method in obtaining high-quality solutions in fewer runs compared to the conventional method.

26 April 2021 in Energies
Verified
Journal Article
Open access
PDF file
GHGhada M. Hammad
Ghada M. Hammad
DIDoaa Ibrahim
Doaa Ibrahim
EZEssam Aboul Zahab
Essam Aboul Zahab
Ahmed F. ZobaaAhmed F. Zobaa
Ahmed F. Zobaa
This paper proposes an adaptive dynamic Mho distance relay based on a phase comparator scheme for protecting interconnected transmission networks compensated with a Thyristor Controlled Series Capacitor (TCSC). The proposed relay uses an impedance index factor to initiate the fault detection subroutine. The RMS of the positive sequence current of the faulted loop and the TCSC terminal current are compared for TCSC zone identification. A phase comparator for ground and phase distance elements is proposed, relying on the positive sequence voltage as a polarized memory quantity, while the operating and polarizing quantities are developed using estimated TCSC impedance to mitigate its negative impact. The proposed scheme is easy in implementation and independent on synchronized data transfer, as minimum communication requirements are needed. To evaluate the performance of the proposed scheme, extensive simulation studies were carried out on an IEEE9 bus system compensated with TCSC for different firing angles covering four modes of TCSC operations, different fault types, and fault locations. In addition, an IEEE-39 bus network, as a large interconnected system, is tested for validation purposes. The achieved results designate the precision of the proposed scheme. Moreover, the results indicate its effectiveness for fault resistance tolerance, close-in three phase faults, and stable power swing phenomenon compared with conventional relays.

1 March 2017 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
DIDoaa Ibrahim
Doaa Ibrahim
EZEssam Aboul Zahab
Essam Aboul Zahab
SMSaadoun Abd El Aziz Mostafa
Saadoun Abd El Aziz Mostafa
New Coordination Approach to Minimize the Number of Re-adjusted Relays When Adding DGs in Interconnected Power Systems Distributed Generation (DG);Pickup Current Setting (IP);Relays Coordination;Time-Dial Setting (TDS); The presence of DGs in power system networks tends to negatively affect the protective relays coordination. The proposed method introduces an approach to minimize the numbers of relays that acquire new settings on contrary to their original settings (case without DG), to achieve relays coordination in case of adding DG, since relays coordination with minimum number of relays of re-adjusted settings represents economical target, especially in networks containing mixture of electromechanical and adaptive digital relays. The scheme decides the possible minimum number of re-adjusted relays and their locations in an optimum manner to achieve proper relays coordination in case of adding DGs. The proposed approach is divided into two successive phases; the first phase is stopped when the first relays coordination solution is achieved. The second phase increases the possibility to keep higher number of relays at their original settings than that obtained in first phase through achieving multi solutions of relays coordination. The proposed approach is implemented and effectively tested on the well-known IEEE-39 bus test system.

28 October 2021 in Energies
Verified
Journal Article
Open access
PDF file
GHGhada M. Hammad
Ghada M. Hammad
DIDoaa Ibrahim
Doaa Ibrahim
EZEssam Aboul Zahab
Essam Aboul Zahab
Ahmed F. ZobaaAhmed F. Zobaa
Ahmed F. Zobaa
A two-fold adaptive dynamic quadrilateral relay is developed in this research for protecting Thyristor-Controlled Series Compensator (TCSC)-compensated transmission lines (TLs). By investigating a new tilt angle and modifying the Takagi method to recognize the fault zone identifier, the proposed relay adapts its reactive reach and resistive reach separately and independently. The investigated tilt angle and identified fault zone use the TCSC reactance to compensate its effect on the TL parameters and system homogeneity. Excessive tests are simulated by MATLAB on the non-homogenous network, IEEE-9 bus system and further tests are carried out on IEEE-39 bus system in order to generalize and validate the efficiency of the proposed approach. The designed trip boundaries are able to detect wide range of resistive faults under all TCSC modes of operations. The proposed approach is easy to implement as there no need for data synchronization or a high level of computation and filtration. Moreover, the proposed adaptive dynamic relay can be applied for non-homogeneity systems and short as well as long TLs which are either TCSC-compensated or -uncompensated TLs.