Tobias Baur

Mr. Tobias Baur

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2017 in Environments
Verified
Journal Article
Open access
PDF file
ASAndreas Schütze
Andreas Schütze
TBTobias Baur
Tobias Baur
MLMartin Leidinger
Martin Leidinger
WRWolfhard Reimringer
Wolfhard Reimringer
RJRalf Jung
Ralf Jung
Tilman SauerwaldTilman Sauerwald
Tilman Sauerwald
Monitoring of volatile organic compounds (VOCs) is of increasing importance in many application fields such as environmental monitoring, indoor air quality, industrial safety, fire detection, and health applications. The challenges in all of these applications are the wide variety and low concentrations of target molecules combined with the complex matrix containing many inorganic and organic interferents. This paper will give an overview over the application fields and address the requirements, pitfalls, and possible solutions for using low-cost sensor systems for VOC monitoring. The focus lies on highly sensitive metal oxide semiconductor gas sensors, which show very high sensitivity, but normally lack selectivity required for targeting relevant VOC monitoring applications. In addition to providing an overview of methods to increase the selectivity, especially virtual multisensors achieved with dynamic operation, and boost the sensitivity further via novel pro-concentrator concepts, we will also address the requirement for high-performance gas test systems, advanced solutions for operating and read-out electronic, and, finally, a cost-efficient factory and on-site calibration. The various methods will be primarily discussed in the context of requirements for monitoring of indoor air quality, but can equally be applied for environmental monitoring and other fields.

19 May 2021 in Atmosphere
Verified
Journal Article
Open access
PDF file
TBTobias Baur
Tobias Baur
JAJohannes Felix Amann
Johannes Felix Amann
CSCaroline Schultealbert
Caroline Schultealbert
ASAndreas Schütze
Andreas Schütze
More and more metal oxide semiconductor (MOS) gas sensors with digital interfaces are entering the market for indoor air quality (IAQ) monitoring. These sensors are intended to measure volatile organic compounds (VOCs) in indoor air, an important air quality factor. However, their standard operating mode often does not make full use of their true capabilities. More sophisticated operation modes, extensive calibration and advanced data evaluation can significantly improve VOC measurements and, furthermore, achieve selective measurements of single gases or at least types of VOCs. This study provides an overview of the potential and limits of MOS gas sensors for IAQ monitoring using temperature cycled operation (TCO), calibration with randomized exposure and data-based models trained with advanced machine learning. After lab calibration, a commercial digital gas sensor with four different gas-sensitive layers was tested in the field over several weeks. In addition to monitoring normal ambient air, release tests were performed with compounds that were included in the lab calibration, but also with additional VOCs. The tests were accompanied by different analytical systems (GC-MS with Tenax sampling, mobile GC-PID and GC-RCP). The results show quantitative agreement between analytical systems and the MOS gas sensor system. The study shows that MOS sensors are highly suitable for determining the overall VOC concentrations with high temporal resolution and, with some restrictions, also for selective measurements of individual components.

10 November 2021 in Atmosphere
Verified
Journal Article
Open access
PDF file
YRYannick Robin
Yannick Robin
JAJohannes Felix Amann
Johannes Felix Amann
TBTobias Baur
Tobias Baur
Payman GoodarziPayman Goodarzi
Payman Goodarzi
CSCaroline Schultealbert
Caroline Schultealbert
ASAndreas Schütze
Andreas Schütze
With air quality being one target in the sustainable development goals set by the United Nations, accurate monitoring also of indoor air quality is more important than ever. Chemiresistive gas sensors are an inexpensive and promising solution for the monitoring of volatile organic compounds, which are of high concern indoors. To fully exploit the potential of these sensors, advanced operating modes, calibration, and data evaluation methods are required. This contribution outlines a systematic approach based on dynamic operation (temperature-cycled operation), randomized calibration (Latin hypercube sampling), and the use of advances in deep neural networks originally developed for natural language processing and computer vision, applying this approach to volatile organic compound measurements for indoor air quality monitoring. This paper discusses the pros and cons of deep neural networks for volatile organic compound monitoring in a laboratory environment by comparing the quantification accuracy of state-of-the-art data evaluation methods with a 10-layer deep convolutional neural network (TCOCNN). The overall performance of both methods was compared for complex gas mixtures with several volatile organic compounds, as well as interfering gases and changing ambient humidity in a comprehensive lab evaluation. Furthermore, both were tested under realistic conditions in the field with additional release tests of volatile organic compounds. The results obtained during field testing were compared with analytical measurements, namely the gold standard gas chromatography mass spectrometry analysis based on Tenax sampling, as well as two mobile systems, a gas chromatograph with photo-ionization detection for volatile organic compound monitoring and a gas chromatograph with a reducing compound photometer for the monitoring of hydrogen. The results showed that the TCOCNN outperforms state-of-the-art data evaluation methods, for example for critical pollutants such as formaldehyde, achieving an uncertainty of around 11 ppb even in complex mixtures, and offers a more robust volatile organic compound quantification in a laboratory environment, as well as in real ambient air for most targets.

27 November 2020 in Journal of Sensors and Sensor Systems
Verified
Journal Article
Open access
PDF file
TBTobias Baur
Tobias Baur
MBManuel Bastuck
Manuel Bastuck
CSCaroline Schultealbert
Caroline Schultealbert
TSTilman Sauerwald
Tilman Sauerwald
ASAndreas Schütze
Andreas Schütze
Applications like air quality, fire detection and detection of explosives require selective and quantitative measurements in an ever-changing background of interfering gases. One main issue hindering the successful implementation of gas sensors in real-world applications is the lack of appropriate calibration procedures for advanced gas sensor systems. This article presents a calibration scheme for gas sensors based on statistically distributed gas profiles with unique randomized gas mixtures. This enables a more realistic gas sensor calibration including masking effects and other gas interactions which are not considered in classical sequential calibration. The calibration scheme is tested with two different metal oxide semiconductor sensors in temperature-cycled operation using indoor air quality as an example use case. The results are compared to a classical calibration strategy with sequentially increasing gas concentrations. While a model trained with data from the sequential calibration performs poorly on the more realistic mixtures, our randomized calibration achieves significantly better results for the prediction of both sequential and randomized measurements for, for example, acetone, benzene and hydrogen. Its statistical nature makes it robust against overfitting and well suited for machine learning algorithms. Our novel method is a promising approach for the successful transfer of gas sensor systems from the laboratory into the field. Due to the generic approach using concentration distributions the resulting performance tests are versatile for various applications.

28 May 2018 in Journal of Sensors and Sensor Systems
Verified
Journal Article
Open access
PDF file
TBTobias Baur
Tobias Baur
CSCaroline Schultealbert
Caroline Schultealbert
ASAndreas Schütze
Andreas Schütze
Tilman SauerwaldTilman Sauerwald
Tilman Sauerwald
A novel method for the detection of short pulses of gas at very low concentrations, the differential surface reduction (DSR), is presented. DSR is related to the temperature pulsed reduction (TPR) method. In a high temperature phase, e.g., at 400 °C, the surface of a metal oxide semiconductor gas sensor (MOS) is oxidized in air and then cooled abruptly down to, e.g., 100 °C, conserving the large excess of negative surface charge. In this state reactions of reducing gases with surface oxygen are strongly favored, which increases the sensitivity. Due to the large energy barrier between metal oxide grains caused by the excess surface charge, a highly precise electrical measurement at very low conductance (down to 10−11 S) is a prerequisite for this method. Moreover, the electrical measurement must be very fast to allow a good resolution of retention times. Applying the method to a doped SnO2 detector, gas pulses down to a dosage of 1 ppb times seconds can be detected. The gas transport inside the detector is simulated using the finite element method (FEM) to optimize the gas transport and to keep response and recovery time as short as possible. With this approach, we have demonstrated a detection limit for ethanol of below 47 fg.

11 March 2021 in Atmosphere
Verified
Journal Article
Open access
PDF file
CSCaroline Schultealbert
Caroline Schultealbert
JAJohannes Felix Amann
Johannes Felix Amann
TBTobias Baur
Tobias Baur
ASAndreas Schütze
Andreas Schütze
Hydrogen is a ubiquitous but often neglected gas. In analytical measurements hydrogen—as a harmless gas—often is not considered so no studies on hydrogen in indoor air can be found. For metal oxide semiconductor (MOS) gas sensors that are increasingly pushed into the application as TVOC (total volatile organic compounds) sensors, hydrogen is a severe disturbance. On the other hand, hydrogen can be an intentional choice as indicator for human presence similar to carbon dioxide. We present a field-study on hydrogen in indoor air using selective MOS sensors accompanied by an analytical reference device for hydrogen with an accuracy of 10 ppb. Selectivity is achieved by siloxane treatment combined with temperature cycled operation and training with a complex lab calibration using randomized gas mixtures, yielding an uncertainty of 40–60 ppb. The feasibility is demonstrated by release tests with several gases inside a room and by comparison to the reference device. The results show that selective MOS sensors can function as cheap and available hydrogen detectors. Fluctuations in hydrogen concentration without human presence are measured over several days to gain insight in this highly relevant parameter for indoor air quality. The results indicate that the topic needs further attention and that the usage of hydrogen as indicator for human presence might be precluded by other sources and fluctuations.