Andreas Schütze

Dr. Andreas Schütze

Lab for Measurement Technology, Saarland University, 6123 Saarbrücken, Germany
orcid

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 May 2018 in Journal of Sensors and Sensor Systems
Verified
Journal Article
Open access
PDF file
ASAndreas Schütze
Andreas Schütze
NHNikolai Helwig
Nikolai Helwig
TSTizian Schneider
Tizian Schneider
“Industrie 4.0” or the Industrial Internet of Things (IIoT) are two terms for the current (r)evolution seen in industrial automation and control. Everything is getting smarter and data generated at all levels of the production process are used to improve product quality, flexibility, and productivity. This would not be possible without smart sensors, which generate the data and allow further functionality from self-monitoring and self-configuration to condition monitoring of complex processes. In analogy to Industry 4.0, the development of sensors has undergone distinctive stages culminating in today's smart sensors or “Sensor 4.0”. This paper briefly reviews the development of sensor technology over the last 2 centuries, highlights some of the potential that can be achieved with smart sensors and data evaluation, and discusses success requirements for future developments. In addition to magnetic sensor technologies which allow self-test and self-calibration and can contribute to many applications due to their wide spectrum of measured quantities, the paper discusses condition monitoring as a primary paradigm for introducing smart sensors and data analysis in manufacturing processes based on two projects performed in our group.

1 March 2017 in Environments
Verified
Journal Article
Open access
PDF file
ASAndreas Schütze
Andreas Schütze
TBTobias Baur
Tobias Baur
MLMartin Leidinger
Martin Leidinger
WRWolfhard Reimringer
Wolfhard Reimringer
RJRalf Jung
Ralf Jung
Tilman SauerwaldTilman Sauerwald
Tilman Sauerwald
Monitoring of volatile organic compounds (VOCs) is of increasing importance in many application fields such as environmental monitoring, indoor air quality, industrial safety, fire detection, and health applications. The challenges in all of these applications are the wide variety and low concentrations of target molecules combined with the complex matrix containing many inorganic and organic interferents. This paper will give an overview over the application fields and address the requirements, pitfalls, and possible solutions for using low-cost sensor systems for VOC monitoring. The focus lies on highly sensitive metal oxide semiconductor gas sensors, which show very high sensitivity, but normally lack selectivity required for targeting relevant VOC monitoring applications. In addition to providing an overview of methods to increase the selectivity, especially virtual multisensors achieved with dynamic operation, and boost the sensitivity further via novel pro-concentrator concepts, we will also address the requirement for high-performance gas test systems, advanced solutions for operating and read-out electronic, and, finally, a cost-efficient factory and on-site calibration. The various methods will be primarily discussed in the context of requirements for monitoring of indoor air quality, but can equally be applied for environmental monitoring and other fields.

1 October 2003 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
AGAndreas Gramm
Andreas Gramm
ASAndreas Schütze
Andreas Schütze

19 May 2021 in Atmosphere
Verified
Journal Article
Open access
PDF file
TBTobias Baur
Tobias Baur
JAJohannes Felix Amann
Johannes Felix Amann
CSCaroline Schultealbert
Caroline Schultealbert
ASAndreas Schütze
Andreas Schütze
More and more metal oxide semiconductor (MOS) gas sensors with digital interfaces are entering the market for indoor air quality (IAQ) monitoring. These sensors are intended to measure volatile organic compounds (VOCs) in indoor air, an important air quality factor. However, their standard operating mode often does not make full use of their true capabilities. More sophisticated operation modes, extensive calibration and advanced data evaluation can significantly improve VOC measurements and, furthermore, achieve selective measurements of single gases or at least types of VOCs. This study provides an overview of the potential and limits of MOS gas sensors for IAQ monitoring using temperature cycled operation (TCO), calibration with randomized exposure and data-based models trained with advanced machine learning. After lab calibration, a commercial digital gas sensor with four different gas-sensitive layers was tested in the field over several weeks. In addition to monitoring normal ambient air, release tests were performed with compounds that were included in the lab calibration, but also with additional VOCs. The tests were accompanied by different analytical systems (GC-MS with Tenax sampling, mobile GC-PID and GC-RCP). The results show quantitative agreement between analytical systems and the MOS gas sensor system. The study shows that MOS sensors are highly suitable for determining the overall VOC concentrations with high temporal resolution and, with some restrictions, also for selective measurements of individual components.

1 January 2014 in Procedia Engineering
Verified
Journal Article
Open access
MLM. Leidinger
M. Leidinger
Tilman SauerwaldTilman Sauerwald
Tilman Sauerwald
TCT. Conrad
T. Conrad
WRW. Reimringer
W. Reimringer
GSGabriela Ventura Silva
Gabriela Ventura Silva
ASAndreas Schütze
Andreas Schütze
A strategy for detecting and identifying trace levels of hazardous volatile organic compounds (VOCs) in indoor air is presented. A metal oxide semiconductor gas sensor in temperature cycled operation is used to detect formaldehyde, benzene and naphthalene in ppb and sub-ppb concentrations with a varying background of ethanol with concentrations of up to 2ppm. Measurement results from a laboratory device have been compared with an integrated sensor system designed for use in field tests. We found that gas emissions from the system itself are an important issue. The emissions have been identified and quantified using analytical methods in order to derive design rules for a proper field test system. However, the results show that selective detection of VOCs in the ppb range is possible even with an intensive background of various VOCs, although sensitivity is reduced compared to the ideal laboratory case

10 November 2021 in Atmosphere
Verified
Journal Article
Open access
PDF file
YRYannick Robin
Yannick Robin
JAJohannes Felix Amann
Johannes Felix Amann
TBTobias Baur
Tobias Baur
Payman GoodarziPayman Goodarzi
Payman Goodarzi
CSCaroline Schultealbert
Caroline Schultealbert
ASAndreas Schütze
Andreas Schütze
With air quality being one target in the sustainable development goals set by the United Nations, accurate monitoring also of indoor air quality is more important than ever. Chemiresistive gas sensors are an inexpensive and promising solution for the monitoring of volatile organic compounds, which are of high concern indoors. To fully exploit the potential of these sensors, advanced operating modes, calibration, and data evaluation methods are required. This contribution outlines a systematic approach based on dynamic operation (temperature-cycled operation), randomized calibration (Latin hypercube sampling), and the use of advances in deep neural networks originally developed for natural language processing and computer vision, applying this approach to volatile organic compound measurements for indoor air quality monitoring. This paper discusses the pros and cons of deep neural networks for volatile organic compound monitoring in a laboratory environment by comparing the quantification accuracy of state-of-the-art data evaluation methods with a 10-layer deep convolutional neural network (TCOCNN). The overall performance of both methods was compared for complex gas mixtures with several volatile organic compounds, as well as interfering gases and changing ambient humidity in a comprehensive lab evaluation. Furthermore, both were tested under realistic conditions in the field with additional release tests of volatile organic compounds. The results obtained during field testing were compared with analytical measurements, namely the gold standard gas chromatography mass spectrometry analysis based on Tenax sampling, as well as two mobile systems, a gas chromatograph with photo-ionization detection for volatile organic compound monitoring and a gas chromatograph with a reducing compound photometer for the monitoring of hydrogen. The results showed that the TCOCNN outperforms state-of-the-art data evaluation methods, for example for critical pollutants such as formaldehyde, achieving an uncertainty of around 11 ppb even in complex mixtures, and offers a more robust volatile organic compound quantification in a laboratory environment, as well as in real ambient air for most targets.