Christian Kühnel

Dr. Christian Kühnel

University Hospital Jena
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 December 2021 in Pharmaceuticals
Verified
Journal Article
Open access
PDF file
FGFalk Gühne
Falk Gühne
SRStefanie Radke
Stefanie Radke
TWThomas Winkens
Thomas Winkens
Christian KühnelChristian Kühnel
Christian Kühnel
JGJulia Greiser
Julia Greiser
MFMartin Freesmeyer
Martin Freesmeyer
The biochemical relapse of prostate cancer is diagnostically challenging but of high clinical impact for subsequent patient treatment. PET/CT with radiolabeled PSMA ligands outperforms conventional diagnostic methods in the detection of tumor recurrence. Several radiopharmaceuticals were and are available for use. The aim of this study was to investigate whether the routinely applied [68Ga]Ga-PSMA ligands PSMA-617, -I&T and -11 (HBED-CC) differ in physiological and pathological distribution, or in tumor detection rate. A retrospective evaluation of 190 patients (39 patients received PSMA-617, 68 patients PSMA-I&T and 83 patients PSMA-11) showed significant differences in tracer accumulation within all organs examined. The low retention within the compartments blood pool, bone and muscle tissue is a theoretical advantage of PSMA-11. Evaluation of tumor lesion uptake and detection rate did not reveal superiority of one of the three radiopharmaceuticals, neither in the whole population, nor in particularly challenging subgroups like patients with very low PSA levels. We conclude that all three [68Ga]Ga-PSMA ligands are equally feasible in this clinically important scenario, and may replace each other in case of unavailability or production restrictions.

4 January 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
PSPhilipp Seifert
Philipp Seifert
IMIvonne Maikowski
Ivonne Maikowski
TWThomas Winkens
Thomas Winkens
Christian KühnelChristian Kühnel
Christian Kühnel
FGFalk Gühne
Falk Gühne
MFMartin Freesmeyer
Martin Freesmeyer
Conventional ultrasound (US) is time-consuming, and results are subjected to high interobserver variability. In this study, the reliability of a novel thyroid US cine loop standard operating procedure (SOP) applied by non-physicians (Medical Technical Assistant, MTA) is investigated. Thirty-three consecutive patients (22 females, 11 males) were enrolled. Patients underwent conventional thyroid US performed by a nuclear medicine physician and additional MTA US cine loop according to a local SOP that includes transversal and sagittal cine loops covering the entire thyroid. The video sequences were transferred to the Picture Archiving and Communication System (PACS) for second reading purposes. MTA US data were not considered for medical reports but for blinded second reading review of the PACS images. The results of conventional physician US reports and reviewed MTA US cine loops were compared regarding size determinations of the thyroid and its nodules, as well as Thyroid Imaging Reporting and Data Systems (TIRADS) classification of all identified lesions. The results revealed very high concordance between conventional physician US and MTA US cine loop review for both size measurements and TIRADS classifications (r(s) = 0.84–0.99, p < 0.0001 each). Minor technical impairments were identified. The evaluated thyroid US cine loop SOP enables reliable second reading results and can be applied by non-physicians.

1 June 2014 in The Journal of Clinical Endocrinology & Metabolism
Verified
Journal Article
Closed access
JWJulian G. Westphal
Julian G. Westphal
TWThomas Winkens
Thomas Winkens
Christian KühnelChristian Kühnel
Christian Kühnel
MFMartin Freesmeyer
Martin Freesmeyer
Radioiodine therapy of benign thyroid diseases requires pretherapy assessment of radioactive iodine uptake (RAIU) for reliable therapy planning. Our objective was to assess RAIU by low-activity (124)I-positron emission tomography/low-dose computed tomography ((124)I-PET/CT) in comparison with standard (131)I probe measurements. This prospective comparative study was conducted at the Jena University Hospital, Jena, Germany, in a referral center setting. A total of 79 patients with benign thyroid diseases were screened, 40 of whom met the inclusion criteria (stable TSH, free T3 and free T4 levels; no thyroid-specific medication, no iodine contamination) and 24 of whom agreed to participate by signing an informed consent. All patients received the standard (131)I scintillation probe uptake test 30 hours after administration of 3 MBq (131)I. Seven days later, all patients were subjected to (124)I-PET/CT uptake measurement 30 hours after administration of 1 MBq (124)I. The decay-corrected uptake values of both techniques were compared. Additionally, 3 different volume-of-interest-based evaluation methods in PET/CT (whole neck [WN], automatic isocontour [IC], and manually contoured [MC]) were evaluated. The (131)I probe measurement and (124)I-PET.WN method provided very similar mean RAIU (30.7% ± 10.3%; 31.7% ± 8.9%), resulting in a significant positive correlation (r = 0.93, P < .001). Compared with (124)I-PET.WN, the (124)I-PET.IC (29.8% ± 8.6%) and the (124)I-PET.MC (24.5% ± 7.1%) demonstrated lower uptake values. Using activities as low as 1 MBq, the (124)I-PET.WN method shows a good correlation with conventional (131)I probe measurement. Thus, (124)I-PET/CT is a suitable alternative for pretherapy RAIU evaluations. This may offer potential additional benefits such as PET/ultrasound fusion imaging and CT volumetry.

16 December 2020 in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
Verified
Journal Article
Closed access
PDF file
UTUlf Teichgräber
Ulf Teichgräber
MIMaja Ingwersen
Maja Ingwersen
HMHans-Joachim Mentzel
Hans-Joachim Mentzel
RARene Aschenbach
Rene Aschenbach
RNRotraud Neumann
Rotraud Neumann
JZJan Zottmann
Jan Zottmann
Purpose To date, didactic lecturing is a common method of university medical training. However, higher levels of competence to solve complex issues are hardly to be achieved with a largely passive learning style. We established and evaluated a heutagogical blended learning concept to investigate self-determined learning with a multimedia-based, interactive approach in the lecture room to teach clinical radiology. Materials and Methods In the 2019/2020 winter semester, we included 266 medical students in their fourth academic year in our prospective, observational study. Students participated in a series of 11 radiological lectures given by 10 lecturers. They were requested to prepare for lectures by watching learning videos. During the lecture, students had to answer key-feature questions (KFQ) in small groups and to jointly submit their answers by means of an audience response system (ARS). After each lecture and the exam, we conducted surveys and compared results with a historical control group. A focus group interview with lecturers was performed after conclusion of the lecture series. Results The students’ overall impression of the “flipped classroom” concept and their examination grades were superior to historical controls (overall impression: 1.5 [95 % CI 1.4–1.6] vs. 2.7 [95 % CI 2.5–2.9] rated on a scale from 1 to 6, p < 0.001; examination grades: 1.8 [95 % CI 1.7–1.9] vs. 2.0 [95 % CI 1.9–2.0] rated on a scale from 1 to 5, p < 0.001). Most students agreed that learning videos (76.6 %), ARS (88.5 %), KFQ (76.5 %), and solution-oriented small group discussions (83.7 %) were useful. Lecturers stated an improved convergence of demands on learning and clinical competence. However, they also emphasized an increased initial effort for implementation. Conclusion Students rated the overall benefit from the heutagogical “flipped classroom” concept as high. Examination grades improved. According to lecturers, the “flipped classroom” concept better matched later professional demands than traditional lectures. Key Points: Citation Format

24 November 2019 in Medical Ultrasonography
Verified
Journal Article
Open access
PDF file
PSPhilipp Seifert
Philipp Seifert
TWThomas Winkens
Thomas Winkens
LKLeonard Knichel
Leonard Knichel
Christian KühnelChristian Kühnel
Christian Kühnel
MFMartin Freesmeyer
Martin Freesmeyer
Aims: To investigate the feasibility and accuracy of 3D-US extended field of view volumetric analyses acquired with mechanically-swept ultrasound probes with different measurement methods for large volume thyroid phantoms.Materials and methods: Fifteen thyroid phantoms with different shapes (regular, nodular, thickened isthmus) and volumes (50-400 mL) were created. Two different mechanically-swept US probes were used for the separate scanning of the left and right lobes: convex and linear probe. After specific modifications, the 3D-US datasets were stitched together to an extended field of view using predefined landmarks. Volumetric analyses were performed by conventional ellipsoid model and manual tracing methods. The correspondence of measured and reference volumes was calculated using Pearson’s correlation coefficients and limits of agreement according to Bland and Altman.Results: The C-probe proved feasible for the acquisition and processing of the three-dimensional ultrasound extended field of view images; very high levels of agreement (correlation coefficients for volume analyses: 0.9843-0.9992) were observed for all shapes and volumes investigated. The manual tracing method showed superior results in comparison to the ellipsoid model, but was more time consuming. The linear probe was only applicable for the 50 mL phantoms due to its limited field of view.Conclusions: The investigated mechanically-swept convex probe was suitable for the three-dimensional ultrasound extended field of view stitching of large volume thyroid phantoms. Accurate volume analyses could be carried out. The mechanically-swept linear probe is limited to a maximum of 50 m

Verified
Journal Article
Open access
PDF file
Christian KühnelChristian Kühnel
Christian Kühnel
AKAlexander Köhler
Alexander Köhler
TBTim Brachwitz
Tim Brachwitz
PSPhilipp Seifert
Philipp Seifert
FGFalk Gühne
Falk Gühne
RDRobert Drescher
Robert Drescher
Transarterial radioembolization (TARE) with 166Ho-loaded microspheres is an established locoregional treatment for hepatocellular carcinoma (HCC), introduced in 2010. This study evaluates the clinical outcome of patients with HCC who underwent 166Ho-TARE with personalized dosimetry. Twenty-seven patients with 36 TARE procedures were analyzed. Treatment planning, execution, and evaluation was possible without complications in all cases. At the 3-month follow-up, disease control in the treated liver was achieved in 81.8% of patients (complete remission, partial remission, and stable disease in 36.4%, 31.8%, and 13.6%, respectively). The median overall survival (OS) was 17.2 months, and progression-free survival (PFS) in the treated liver was 11 months. Statistically significant positive correlations were observed between the achieved radiation dose for the tumor and both PFS (r = 0.62, p < 0.05) and OS (r = 0.48, p < 0.05), suggesting a direct dose–response relationship. The calculated achieved dose was 8.25 Gy lower than the planned dose, with relevant variance between planned and achieved doses in individual cases. These results confirm the efficacy of the 166Ho-TARE holmium platform and underscore the potential of voxel-based, personalized dosimetry to improve clinical outcomes.