Falk Gühne

Dr. Falk Gühne

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 June 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
FGFalk Gühne
Falk Gühne
PSPhilipp Seifert
Philipp Seifert
BTBernhard Theis
Bernhard Theis
MSMatthias Steinert
Matthias Steinert
MFMartin Freesmeyer
Martin Freesmeyer
RDRobert Drescher
Robert Drescher
PET/CT with prostate-specific membrane antigen (PSMA)-targeted tracers has been used in the diagnosis and staging of patients with clear cell renal cell carcinoma (ccRCC). For ccRCC primary tumors, PET parameters were shown to predict histologic grade and features. The aim of this study was to correlate PSMA PET/CT with histopathological findings in patients with metastatic recurrence of ccRCC. Patients with ccRCC who underwent PSMA-targeted PET/CT and subsequent histopathological evaluation of suspicious lesions were included. Specimens underwent immunohistochemical marking. Lesion diameter, volume and tracer uptake were correlated with the extent and intensity of molecular PSMA expression and with clinical findings. Twelve PET-positive lesions of nine patients were evaluated. Eleven ccRCC metastases and one prostate carcinoma were detected histopathologically. Molecular PSMA expression was detected in all lesions, which intensity and distribution did not correlate with PET parameters. PSMA-targeted PET/CT is a feasible tool for the evaluation of patients with ccRCC but cannot reliably predict histologic features of metastases. PSMA may also be expressed in malignant lesions other than ccRCC, leading to incidental detection of these tumors.

22 December 2021 in Pharmaceuticals
Verified
Journal Article
Open access
PDF file
FGFalk Gühne
Falk Gühne
SRStefanie Radke
Stefanie Radke
TWThomas Winkens
Thomas Winkens
Christian KühnelChristian Kühnel
Christian Kühnel
JGJulia Greiser
Julia Greiser
MFMartin Freesmeyer
Martin Freesmeyer
The biochemical relapse of prostate cancer is diagnostically challenging but of high clinical impact for subsequent patient treatment. PET/CT with radiolabeled PSMA ligands outperforms conventional diagnostic methods in the detection of tumor recurrence. Several radiopharmaceuticals were and are available for use. The aim of this study was to investigate whether the routinely applied [68Ga]Ga-PSMA ligands PSMA-617, -I&T and -11 (HBED-CC) differ in physiological and pathological distribution, or in tumor detection rate. A retrospective evaluation of 190 patients (39 patients received PSMA-617, 68 patients PSMA-I&T and 83 patients PSMA-11) showed significant differences in tracer accumulation within all organs examined. The low retention within the compartments blood pool, bone and muscle tissue is a theoretical advantage of PSMA-11. Evaluation of tumor lesion uptake and detection rate did not reveal superiority of one of the three radiopharmaceuticals, neither in the whole population, nor in particularly challenging subgroups like patients with very low PSA levels. We conclude that all three [68Ga]Ga-PSMA ligands are equally feasible in this clinically important scenario, and may replace each other in case of unavailability or production restrictions.

4 January 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
PSPhilipp Seifert
Philipp Seifert
IMIvonne Maikowski
Ivonne Maikowski
TWThomas Winkens
Thomas Winkens
Christian KühnelChristian Kühnel
Christian Kühnel
FGFalk Gühne
Falk Gühne
MFMartin Freesmeyer
Martin Freesmeyer
Conventional ultrasound (US) is time-consuming, and results are subjected to high interobserver variability. In this study, the reliability of a novel thyroid US cine loop standard operating procedure (SOP) applied by non-physicians (Medical Technical Assistant, MTA) is investigated. Thirty-three consecutive patients (22 females, 11 males) were enrolled. Patients underwent conventional thyroid US performed by a nuclear medicine physician and additional MTA US cine loop according to a local SOP that includes transversal and sagittal cine loops covering the entire thyroid. The video sequences were transferred to the Picture Archiving and Communication System (PACS) for second reading purposes. MTA US data were not considered for medical reports but for blinded second reading review of the PACS images. The results of conventional physician US reports and reviewed MTA US cine loops were compared regarding size determinations of the thyroid and its nodules, as well as Thyroid Imaging Reporting and Data Systems (TIRADS) classification of all identified lesions. The results revealed very high concordance between conventional physician US and MTA US cine loop review for both size measurements and TIRADS classifications (r(s) = 0.84–0.99, p < 0.0001 each). Minor technical impairments were identified. The evaluated thyroid US cine loop SOP enables reliable second reading results and can be applied by non-physicians.

Verified
Journal Article
Open access
PDF file
Christian KühnelChristian Kühnel
Christian Kühnel
AKAlexander Köhler
Alexander Köhler
TBTim Brachwitz
Tim Brachwitz
PSPhilipp Seifert
Philipp Seifert
FGFalk Gühne
Falk Gühne
RDRobert Drescher
Robert Drescher
Transarterial radioembolization (TARE) with 166Ho-loaded microspheres is an established locoregional treatment for hepatocellular carcinoma (HCC), introduced in 2010. This study evaluates the clinical outcome of patients with HCC who underwent 166Ho-TARE with personalized dosimetry. Twenty-seven patients with 36 TARE procedures were analyzed. Treatment planning, execution, and evaluation was possible without complications in all cases. At the 3-month follow-up, disease control in the treated liver was achieved in 81.8% of patients (complete remission, partial remission, and stable disease in 36.4%, 31.8%, and 13.6%, respectively). The median overall survival (OS) was 17.2 months, and progression-free survival (PFS) in the treated liver was 11 months. Statistically significant positive correlations were observed between the achieved radiation dose for the tumor and both PFS (r = 0.62, p < 0.05) and OS (r = 0.48, p < 0.05), suggesting a direct dose–response relationship. The calculated achieved dose was 8.25 Gy lower than the planned dose, with relevant variance between planned and achieved doses in individual cases. These results confirm the efficacy of the 166Ho-TARE holmium platform and underscore the potential of voxel-based, personalized dosimetry to improve clinical outcomes.

27 January 2023 in Biomedicines
Verified
Journal Article
Open access
PDF file
PSPhilipp Seifert
Philipp Seifert
SUSophie-Luise Ullrich
Sophie-Luise Ullrich
Christian KühnelChristian Kühnel
Christian Kühnel
FGFalk Gühne
Falk Gühne
RDRobert Drescher
Robert Drescher
MFMartin Freesmeyer
Martin Freesmeyer
Ultrasound (US) is the most important imaging method for the assessment of structural disorders of the thyroid. A precise volume determination is relevant for therapy planning and outcome monitoring. However, the accuracy of 2D-US is limited, especially in cases of organ enlargements and deformations. Software-based “stitching” of separately acquired 3D-US data revealed precise volume determination in thyroid phantoms. The purpose of this study is to investigate the feasibility and accuracy of 3D-US stitching in patients with structural thyroid disease. A total of 31 patients from the clinical routine were involved, receiving conventional 2D-US (conUS), sensor-navigated 3D-US (3DsnUS), mechanically-swept 3D-US (3DmsUS), and I-124-PET/CT as reference standard. Regarding 3DsnUS and 3DmsUS, separately acquired 3D-US images (per thyroid lobe) were merged to one comprehensive data set. Subsequently, anatomical correctness of the stitching process was analysed via secondary image fusion with the I-124-PET images. Volumetric determinations were conducted by the ellipsoid model (EM) on conUS and CT, and manually drawn segmental contouring (MC) on 3DsnUS, 3DmsUS, CT, and I-124-PET/CT. Mean volume of the thyroid glands was 44.1 ± 25.8 mL (I-124-PET-MC = reference). Highly significant correlations (all p < 0.0001) were observed for conUS-EM (r = 0.892), 3DsnUS-MC (r = 0.988), 3DmsUS-MC (r = 0.978), CT-EM (0.956), and CT-MC (0.986), respectively. The mean volume differences (standard deviations, limits of agreement) in comparison with the reference were −10.50 mL (±11.56 mL, −33.62 to 12.24), −3.74 mL (±3.74 mL, −11.39 to 3.78), and 0.62 mL (±4.79 mL, −8.78 to 10.01) for conUS-EM, 3DsnUS-MC, and 3DmsUS-MC, respectively. Stitched 3D-US data sets of the thyroid enable accurate volumetric determination even in enlarged and deformed organs. The main limitation of high time expenditure may be overcome by artificial intelligence approaches.

17 June 2020 in Sensors
Verified
Journal Article
Open access
PDF file
MFMartin Freesmeyer
Martin Freesmeyer
TWThomas Winkens
Thomas Winkens
LWLuis Weissenrieder
Luis Weissenrieder
Christian KühnelChristian Kühnel
Christian Kühnel
FGFalk Gühne
Falk Gühne
PSPhilipp Seifert
Philipp Seifert
In conventional thyroid diagnostics, the topographical correlation between thyroid nodules (TN) depicted on ultrasound (US) in axial or sagittal orientation and coronally displayed scintigraphy images can be challenging. Sensor-navigated I-124-PET/US fusion imaging has been introduced as a problem-solving tool for ambiguous cases. The purpose of this study was to investigate the results of multiple unexperienced medical students (MS) versus multiple nuclear medicine physicians (MD) regarding the overvalue of I-124-PET/US in comparison to conventional diagnostics (CD) for the functional assessment of TN. Methods: Out of clinical routine, cases with ambiguous findings on CD were selected for I-124-PET/US fusion imaging. Sixty-eight digital patient case files (PCF) of 34 patients (CDonly and CD+PET/US PCF) comprising 66 TN were provided to be retrospectively evaluated by 70 MD and 70 MS, respectively. A total of 2174 ratings (32.9 per TN) were carried out: 555 ratings (8.4 per TN) for CDonly and 532 ratings (8.1 per TN) for CD+PET/US by each MD and MS. Results: Functional assessment revealed 8.5%/11.7% (n.s.) (16.4%/25.8% (p = 0.0002)), 41.8%/28.5% (p < 0.0001) (23.9%/17.9% (p = 0.0193)), 36.0%/30.5% (n.s.) (57.3%/53.9% (n.s.)), and 13.7%/29.4% (p < 0.0001) (2.4%/2.4% (n.s.)) hyperfunctioning, indifferent, hypofunctioning, and not rateable TNs for CDonly (CD+PET/US) and MD/MS, respectively. The respective rating confidence was indicated as absolute certain, quite certain, equivocal, uncertain, and not rateable in 11.7/3.4% (p < 0.0001) (44.9%/38.9% (p = 0.0541), 51.9%/26.7% (p < 0.0001) (46.2%/41.5% (n.s.)), 21.6%/29.0% (p = 0.0051) (6.2%/14.8% (p < 0.0001)), 1.1%/11.5% (p < 0.0001) (0.2%/2.3% (p = 0.0032)), and 13.7%/29.4% (p < 0.0001) (2.4%/2.4% (n.s.)) by MD/MS, respectively. There was a significant difference in the diversity of the observers’ functional assessment of TN (MD 0.84 vs. MS 1.02, p = 0.0006) and the respective confidence in functional assessment (MD 0.93 vs. MS 1.16, p < 0.0001) between MD and MS on CDonly, whereas CD+PET/US revealed weaker differences for both groups (MD 0.48 vs. MS 0.47, p = 0.57; and MD 0.66 vs. MS 0.83, p = 0.0437). With the additional application of I-124-PET/US, the rating diversity of both MD and MS markedly tends towards more consistency (p < 0.0001 in each case). Conclusion: The additional application of sensor-navigated I-124-PET/US fusion imaging significantly influenced the functional assessment of TN positively, especially for unexperienced observers.