The emergence of microgrids and the increasing adoption of Distributed Generation Systems (DGS) have created an opportunity to replace traditional fossil fuels with renewable resources. Such a shift poses security and power quality challenges that must be addressed by academics and industrial research paradigms. Unintentional islanding is an important security concern, as it can result in power quality degradation, electrical hazards, and equipment damage. To address this problem and find efficient solutions, many anti-islanding techniques to detect and eliminate the phenomenon can be found in the specialized literature. These solutions can be classified as passive, active, remote, hybrid, or based on machine learning and signal processing techniques. In this context, this paper provides a comprehensive review of existing anti-islanding methods, highlighting their importance in preventing dangerous situations. The review includes a detailed analysis of advantages and limitations found for each method, as well as its suitability for practical applications. The goal is to provide a valuable resource for researchers and practitioners in the field of distributed power systems, enabling them to choose the most appropriate anti-islanding method for their specific needs. Overall, this paper aims to address the challenges posed by unintentional islanding and promote the adoption of renewable energy resources for a more sustainable future.
This paper presents a study regarding the development of a single-stage single-phase grid-tied photovoltaic (PV) inverter with a new Global Maximum Power Point Tracking (GMPPT) technique. The proposed strategy is based on the indirect PV array voltage control and allows for the development of PV inverter with reduced number of sensors, therefore, increasing the system reliability and reducing costs. The proposed strategy was denominated Sensorless PV Array Voltage Control for Global Maximum Power Point Tracking (SPVAVC-GMPPT). The static and dynamic accuracy of the GMPPT algorithm has been demonstrated to be over 99% under different operating conditions of irradiance and temperature and also under shading conditions, where multiple false Maximum Power Points (MPPs) occur. Simulation and experimental results are shown, compared, and discussed, with a 99,45% TF for standard-test conditions (STC – 25 °C and 1000 W/m²) and even higher (99,96%) under different irradiance and temperature proving the effectiveness of the proposed technique.
The protection against the unintentional islanding of Grid-Tied inverters is an important electrical security issue addressed by the main Standards. This concern is justified in face of the fact that unintentional islanding can lead to abrupt variations of voltage and frequency, electrical damages, professional accidents, power quality degradation, and out-of-phase reclosure. In response to the islanding concern, the literature has proposed several Anti-Islanding Protection (AIP) schemes that can be divided in passive and active methods. Many of the active AIP is based on the insertion of some disturbance in the inverter current in order to deviate the frequency out of the allowed thresholds, tripping the inverter internal disconnection system. Thus, the main objective of this paper is to analyze the performance of the Active Phase Jump with Positive Feedback (APJPF) algorithm compared to other well-known frequency drift-based solutions. More than that, this work covers the Non-Detection Zone (NDZ) problem, analyzing its main mapping methodologies and the normative requirements, exposing the minimum normative recommendations a given AIP must reach to be considered functional. The last contributions of this paper are the proposal of a parametrization criterion for the Active Frequency Drift with Pulsating Chopping Factor (AFDPCF) and for the APJPF.
7 October 2025 in IEEE Transactions on Industry Applications
Short-Duration Voltage Variations (SDVVs) are phenomena that significantly impact power quality. Although they typically last no longer than three minutes, such events can disrupt load operations and cause substantial production losses. This study presents an enhanced methodology for determining whether an SDVV event originates upstream or downstream of the point of common coupling between two agents interconnected through a transformer. Building upon the work of Ferreira et al., whose original approach was applied to a circuit using MATLAB/Simulink, this research advances the methodology by applying it to both real and benchmark distribution systems using open-source tools, namely QGIS, OpenDSS, and Python™. The well-known IEEE 34-Bus Test System has been used to verify the methodology’s generalizability. The method was also further validated through tests conducted on two actual Brazilian distribution feeders in Uberlândia, Minas Gerais: one supplying large industrial consumers such as a rice mill and a carbonated beverages factory, and the other serving a municipal wastewater treatment plant and a large photovoltaic plant. By using real, detailed and georeferenced data, the approach ensures an accurate representation of both the network topology and the installed equipment. The results confirm that the proposed methodology reliably identifies the origin of SDVV events. A key contribution of this study is that the attribution of responsibility remains robust regardless of variations in transformer winding configurations, fault resistance, circuit topology, load characteristics, or the presence of distributed generation. These findings demonstrate the accessibility, robustness and practical applicability, offering a valuable tool for utilities and researchers aiming to enhance power quality and accountability in distribution networks.
Research on hybrid microgrids has attracted significant interest mainly due to the advantages that this topology offers compared to a solely direct current (DC) or alternating current (AC) microgrid. Among these advantages, one of the most frequently mentioned is the increased system reliability, due to the possibility of operating in either islanded mode or grid-connected mode, depending on the need. Additionally, the ability to export power to the AC grid is a valuable application of this type of system. In this context, this paper proposes a new control and management strategy for a hybrid microgrid. The analyzed microgrid consists of a photovoltaic system, energy storage systems, and an emergency power source, as well as DC and AC loads. The interface with the AC side is achieved through an inverter, and the microgrid may or may not be connected to the external grid. The proposed strategy emphasizes the management of all subsystems, as well as the control of operations in both grid-connected and islanded modes. The system was implemented using Controller Hardware-in-the-Loop (C-HIL). The results demonstrated that the proposed strategy enabled effective microgrid management, particularly regarding the proper coordination of the batteries through SOC equalization and the maintenance of each operational state of the microgrid.