Salvatore Russo

Mr. Salvatore Russo

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
LCLuigi Cosentino
Luigi Cosentino
QDQuentin Ducasse
Quentin Ducasse
MGMARTINA GIUFFRIDA
MARTINA GIUFFRIDA
SMSergio Lo Meo
Sergio Lo Meo
Fabio LonghitanoFabio Longhitano
Fabio Longhitano
Paolo FinocchiaroPaolo Finocchiaro
Paolo Finocchiaro
In the framework of the MICADO (Measurement and Instrumentation for Cleaning And Decommissioning Operations) European Union (EU) project, aimed at the full digitization of low- and intermediate-level radioactive waste management, a set of 32 solid state thermal neutron detectors named SiLiF has been built and characterized. MICADO encompasses a complete active and passive characterization of the radwaste drums with neutrons and gamma rays, followed by a longer-term monitoring phase. The SiLiF detectors are suitable for the monitoring of nuclear materials and can be used around radioactive waste drums possibly containing small quantities of actinides, as well as around spent fuel casks in interim storage or during transportation. Suitable polyethylene moderators can be exploited to better shape the detector response to the expected neutron spectrum, according to Monte Carlo simulations that were performed. These detectors were extensively tested with an AmBe neutron source, and the results show a quite uniform and reproducible behavior.

1 August 2020 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
DPDomenico Lo Presti
Domenico Lo Presti
Nilberto MedinaNilberto Medina
Nilberto Medina
MGMarcilei Aparecida Guazzelli
Marcilei Aparecida Guazzelli
MMMauricio Moralles
Mauricio Moralles
VAVitor Aguiar
Vitor Aguiar
NUNumencollaboration
Numencollaboration
The NUMEN (NUclear Matrix Elements for Neutrinoless double beta decay) project was recently proposed with the aim to investigate the nuclear response to Double Charge Exchange reactions for all the isotopes explored by present and future studies of 0νββ decay. The expected level of radiation in the NUMEN experiment imposes severe limitations on the average lifetime of the electronic devices. During the experiments, it is expected that the electronic devices will be exposed to about 105 neutrons/cm2/s according to FLUKA simulations. This paper investigates the reliability of a System On Module (SOM) under neutron radiation. The tests were performed using thermal, epithermal, and fast neutrons produced by the Instituto de Pesquisas Energéticas e Nucleares 4.5 MW Nuclear Research Reactor. The results show that the National Instruments SOM is robust to neutron radiation for the proposed applications in the NUMEN project.