Frank Narducci

Dr. Frank Narducci

Naval Postgraduate School, Monterey, CA 93943, USA
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 March 2022 in Advances in Physics: X
Verified
Journal Article
Closed access
Frank NarducciFrank Narducci
Frank Narducci
ABAdam T. Black
Adam T. Black
JBJohn H. Burke
John H. Burke
We review the field of atom interferometer inertial sensors. We begin by reviewing the path integral formulation of atom interferometers and then specialize the treatment to light-pulse atom interferometers and, in particular, gravimeters and gyroscopes. The bulk of the article focuses on the most common type of atom interferometer – the light-pulse interferometer, where the atom optics are composed of light pulses. Our article mainly focuses on a review of advances that aid in the practical implementation of atom interferometers toward gravimetry and inertial navigation. To that end, we develop a navigation model that aids in the connection of parameters and performance of atom interferometers to actual quantities of interest to the navigation community. Practical considerations of atomic inertial sensors, including dynamic range, bandwidth, dead time, and cross-coupling effects are discussed, before we review the field of accelerometer and gyroscope atom interferometers. Finally, we review advances in trapped-atom interferometers. Graphical abstract

25 November 2019 in Physical Review Research
Verified
Journal Article
Open access
PDF file
DGDario Gatto
Dario Gatto
PFPaolo Facchi
Paolo Facchi
Frank NarducciFrank Narducci
Frank Narducci
VTVincenzo Tamma
Vincenzo Tamma
We propose an interferometric scheme for the estimation of a linear combination with non-negative weights of an arbitrary number M>1 of unknown phase delays, distributed across an M-channel linear optical network, with Heisenberg-limited sensitivity. This is achieved without the need of any sources of photon-number or entangled states, photon-number-resolving detectors, or auxiliary interferometric channels. Indeed, the proposed protocol remarkably relies upon a single squeezed-state source, an antisqueezing operation at the interferometer output, and on-off photodetectors.

16 February 2021 in Physical Review Research
Verified
Journal Article
Open access
PDF file
GGGiovanni Gramegna
Giovanni Gramegna
DTDanilo Triggiani
Danilo Triggiani
PFPaolo Facchi
Paolo Facchi
Frank NarducciFrank Narducci
Frank Narducci
VTVincenzo Tamma
Vincenzo Tamma
We propose a measurement setup reaching Heisenberg scaling precision for the estimation of any distributed parameter φ (not necessarily a phase) encoded into a generic M-port linear network composed only of passive elements. The scheme proposed can be easily implemented from an experimental point of view since it employs only Gaussian states and Gaussian measurements. Due to the complete generality of the estimation problem considered, it was predicted that one would need to carry out an adaptive procedure which involves both the input states employed and the measurement performed at the output; we show that this is not necessary: Heisenberg scaling precision is still achievable by only adapting a single stage. The nonadapted stage only affects the value of a prefactor multiplying the Heisenberg scaling precision: We show that, for large values of M and a random (unbiased) choice of the nonadapted stage, this prefactor takes a typical value which can be controlled through the encoding of the parameter φ into the linear network.

4 December 2025 in The European Physical Journal Special Topics
Verified
Journal Article
Closed access
PDF file
MMMichael Manicchia
Michael Manicchia
JBJens Berdahl
Jens Berdahl
TTTakaho Tsubakiyama
Takaho Tsubakiyama
Frank NarducciFrank Narducci
Frank Narducci

5 March 2023 in Atoms
Verified
Journal Article
Open access
PDF file
MMMichael Manicchia
Michael Manicchia
JLJeffrey G. Lee
Jeffrey G. Lee
Frank NarducciFrank Narducci
Frank Narducci
The use of atom interferometers in inertial systems holds the promise of improvement of several orders of magnitude in sensitivity over sensors using current technology such as micro-electro-mechanical (MEMS) devices or ring laser gyroscopes (RLGs). This paper describes the construction and characterization of an atomic interferometry system for eventual use in a dual-atom-beam accelerometer/gyroscope sensor. In contrast with current state-of-the-art atomic sensors which use pulsed cold atom sources and pulsed laser beams, the investigated apparatus relies purely on continuous atomic and laser beams. These differences can result in a sensor with reduced complexity, a smaller physical footprint, and reduced power consumption. However, these differences also introduce challenges resulting from laser and atomic beam divergences and from velocity averaging due to both longitudinal and transverse velocity spreads. In this work, we characterize our rubidium-based atom beam system and show that Ramsey-style interference can still be observed. The implications for future research are also outlined and discussed.

13 December 2023 in The European Physical Journal Special Topics
Verified
Journal Article
Closed access
PDF file
JLJeffrey Lee
Jeffrey Lee
Frank NarducciFrank Narducci
Frank Narducci