We demonstrate the ultimate sensitivity allowed by quantum physics in the estimation of the time delay between two photons by measuring their interference at a beam splitter through frequency-resolving sampling measurements. This sensitivity can be increased quadratically by decreasing the photonic temporal bandwidth even at values smaller than the time delay when standard two-photon interferometers become inoperable and without adapting the path of the reference photon, nor the need of time-resolving detectors with an unfeasible high resolution. Applications can range from the more feasible imaging of nanostructures, including biological samples, and nanomaterial surfaces to quantum enhanced estimation based on frequency-resolved boson sampling in optical networks.
We present a quantum sensing scheme achieving the ultimate quantum sensitivity in the estimation of the transverse displacement between two photons interfering at a balanced beam splitter, based on transverse-momentum sampling measurements at the output. This scheme can possibly lead to enhanced high-precision nanoscopic techniques, such as superresolved single-molecule localization microscopy with quantum dots, by circumventing the requirements in standard direct imaging of camera resolution at the diffraction limit, and of highly magnifying objectives. Interestingly, we show that our interferometric technique achieves the ultimate spatial precision in nature irrespectively of the overlap of the two displaced photonic wave packets, while its precision is only reduced of a constant factor for photons differing in any nonspatial degrees of freedom. This opens a new research paradigm based on the interface between spatially resolved quantum interference and quantum-enhanced spatial sensitivity.
Fluorescence Lifetime Imaging Microscopy in the time domain is typically performed by recording the arrival time of photons either by using electronic time tagging or a gated detector. As such the temporal resolution is limited by the performance of the electronics to 100’s of picoseconds. Here, we demonstrate a fluorescence lifetime measurement technique based on photon-bunching statistics with a resolution that is only dependent on the duration of the reference photon or laser pulse, which can readily reach the 1–0.1 picosecond timescale. A range of fluorescent dyes having lifetimes spanning from 1.6 to 7 picoseconds have been here measured with only ~1 s measurement duration. We corroborate the effectiveness of the technique by measuring the Newtonian viscosity of glycerol/water mixtures by means of a molecular rotor having over an order of magnitude variability in lifetime, thus introducing a new method for contact-free nanorheology. Accessing fluorescence lifetime information at such high temporal resolution opens a doorway for a wide range of fluorescent markers to be adopted for studying yet unexplored fast biological processes, as well as fundamental interactions such as lifetime shortening in resonant plasmonic devices.
We propose a metrological strategy reaching Heisenberg-scaling precision in the estimation of functions of any fixed number of arbitrary parameters encoded in a generic -channel linear network. This scheme is experimentally feasible since it only employs a single-mode squeezed vacuum and homodyne detection on a single output channel. Two auxiliary linear networks are required and their role is twofold: to refocus the signal into a single channel after the interaction with the interferometer, and to fix the function of the parameters to be estimated according to the linear network analyzed. Although the refocusing requires some knowledge on the parameters, we show that the required precision on the prior measurement is achievable with a classic measurement. We conclude by discussing two paradigmatic schemes in which the choice of the auxiliary stages allows us to change the function of the unknown parameter to estimate.
We propose a measurement setup reaching Heisenberg scaling precision for the estimation of any distributed parameter (not necessarily a phase) encoded into a generic -port linear network composed only of passive elements. The scheme proposed can be easily implemented from an experimental point of view since it employs only Gaussian states and Gaussian measurements. Due to the complete generality of the estimation problem considered, it was predicted that one would need to carry out an adaptive procedure which involves both the input states employed and the measurement performed at the output; we show that this is not necessary: Heisenberg scaling precision is still achievable by only adapting a single stage. The nonadapted stage only affects the value of a prefactor multiplying the Heisenberg scaling precision: We show that, for large values of and a random (unbiased) choice of the nonadapted stage, this prefactor takes a typical value which can be controlled through the encoding of the parameter into the linear network.
We consider the estimation of an arbitrary parameter φ, such as the temperature or a magnetic field, affecting in a distributed manner the components of an arbitrary linear optical passive network, such as an integrated chip. We demonstrate that Heisenberg scaling precision (i.e. of the order of 1/N, where N is the number of probe photons) can be achieved without any iterative adaptation of the interferometer hardware and by using only a simple, single, squeezed light source and well-established homodyne measurements techniques. Furthermore, no constraint on the possible values of the parameter is needed but only a preliminary shot-noise estimation (i.e. with a precision of ) easily achievable without any quantum resources. Indeed, such a classical knowledge of the parameter is enough to prepare a single, suitable optical stage either at the input or the output of the network to monitor with Heisenberg-limited precision any variation of the parameter to the order of without the need to iteratively modify such a stage.