Corentin Féry

Mr. Corentin Féry

University of Applied Sciences and Arts Northwestern Switzerland
+2
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2022 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Closed access
PDF file
CFCorentin Féry
Corentin Féry
ADAdrien Desombre
Adrien Desombre
TQThomas Quirin
Thomas Quirin
PBPatrick Badertscher
Patrick Badertscher
CSChristian Sticherling
Christian Sticherling
JPJoris Pascal
Joris Pascal

10 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
TQThomas Quirin
Thomas Quirin
CFCorentin Féry
Corentin Féry
DVDorian Vogel
Dorian Vogel
CVCéline Vergne
Céline Vergne
MSMathieu Sarracanie
Mathieu Sarracanie
JPJoris Pascal
Joris Pascal
This paper presents a tracking system using magnetometers, possibly integrable in a deep brain stimulation (DBS) electrode. DBS is a treatment for movement disorders where the position of the implant is of prime importance. Positioning challenges during the surgery could be addressed thanks to a magnetic tracking. The system proposed in this paper, complementary to existing procedures, has been designed to bridge preoperative clinical imaging with DBS surgery, allowing the surgeon to increase his/her control on the implantation trajectory. Here the magnetic source required for tracking consists of three coils, and is experimentally mapped. This mapping has been performed with an in-house three-dimensional magnetic camera. The system demonstrates how magnetometers integrated directly at the tip of a DBS electrode, might improve treatment by monitoring the position during and after the surgery. The three-dimensional operation without line of sight has been demonstrated using a reference obtained with magnetic resonance imaging (MRI) of a simplified brain model. We observed experimentally a mean absolute error of 1.35 mm and an Euclidean error of 3.07 mm. Several areas of improvement to target errors below 1 mm are also discussed.

15 March 2024 in Proceedings
Verified
Conference Paper
Open access
PDF file
TQThomas Quirin
Thomas Quirin
CFCorentin Féry
Corentin Féry
CVCéline Vergne
Céline Vergne
MMMADEC Morgan
MADEC Morgan
LHLuc Hebrard
Luc Hebrard
JPJoris Pascal
Joris Pascal
This article presents a magnetic tracking system using on-chip anisotropic magnetoresistive (AMR) sensors. The system consists of four air-core coils sequentially generating four dc magnetic fields. The implemented localization algorithm is quadrilateration, and the accuracy of the system is dependent on the accuracy of the sensors and the simulated field maps. The performance of the system was evaluated using an in-house magnetic field camera (MFC), and the results showed that the system exhibits mean Euclidean errors below 1 mm where the source produces strong gradients. Given the dimensions of the sensors (0.82 × 0.82 mm2), this system is suitable for tracking minimally invasive surgical tools.

28 March 2025 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
HNHugo Nicolas
Hugo Nicolas
CFCorentin Féry
Corentin Féry
TQThomas Quirin
Thomas Quirin
NWNicolas Weber
Nicolas Weber
JOJulien Oster
Julien Oster
JPJoris Pascal
Joris Pascal
Purpose: The aim of this paper is to introduce a new magnetic field exposimeter device that consists of goggles equipped with magnetic sensors for the assessment of the field exposure of MRI workers' heads. This is not possible with conventional pocket exposimeters. Hence, this device allows head‐level field exposure to be measured, which can induce physiological effects on MRI workers, and which are required to be covered by managing the laboratory‐related safety hazards directive 2013/35/EU. Methods: Using on‐chip monolithic three‐axis Hall effect magnetometers, recently introduced on the market, we developed an exposimeter with unprecedented accuracy, which allows the measurement of the magnetic field closed to the organs which are the most impacted by strong magnetic fields: the brain, the eyes, and the tongue. Results: The exposimeter prototypes were successfully tested around 3 T, 7 T, and 11.7 T MRI scanners on different workers and volunteers in real conditions. Comparisons with chest‐level measurements lead typically to lower values than exposure recorded at the head‐level, confirming the need for such head‐level assessments. Exposure of the head above the limits established by the directive was also recorded (>2 T or >2.7 T/s). Conclusion: This new exposimeter allows for a more accurate assessment of field exposure of MRI workers. Further improvements in the miniaturization and the usability of the exposimeter will allow us to disseminate the device and open the way to a larger‐scale study.