Marco Ferroni

Dr. Marco Ferroni

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 July 2020 in Medical Engineering & Physics
Verified
Journal Article
Closed access
MFMarco Ferroni
Marco Ferroni
FGFrancesco De Gaetano
Francesco De Gaetano
MCMatteo Giuseppe Cereda
Matteo Giuseppe Cereda
FBFederica Boschetti
Federica Boschetti
The purpose of this study is to investigate the effect of vitreous sloshing induced by saccades on the intravitreal delivery of large molecule drugs. The vitreous body was considered in its age-related liquefaction condition. Fluid dynamics and large molecule distribution were described by the coupling of mass conservation's and Fick's laws with continuity and momentum equations for a Newtonian incompressible fluid in a 3D unsteady analysis. Two injection sites were analyzed, in both the mixing effect of a 50° periodic saccade leads to uniform drug distribution in 30 s of simulation, the initial bolus site being left after 3 s of simulation. In absence of saccadic movements, the dominant transport contribution is the diffusive one and large molecules hardly reach their uniform distribution inside the vitreous cavity. A model describing the intravitreal distribution of large molecules in presence of saccades was developed, improving the understanding of drug transport mechanism after an intravitreal injection and highlighting how advection contribution enhances its distribution in the vitreous chamber.

7 August 2018 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
MFMarco Ferroni
Marco Ferroni
MCMatteo Giuseppe Cereda
Matteo Giuseppe Cereda
FBFederica Boschetti
Federica Boschetti

23 June 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
Margherita PizziMargherita Pizzi
Margherita Pizzi
ACAntonio Costetti
Antonio Costetti
FGFrancesco De Gaetano
Francesco De Gaetano
MFMarco Ferroni
Marco Ferroni
FAFrancesco Arleo
Francesco Arleo
MAMassimiliano Annoni
Massimiliano Annoni
Size effects, high thrust forces, limited heat dissipation, and tool deterioration are just some of the challenges that deep microdrilling poses, underscoring the importance of effective process control to ensure quality. In this paper, an investigation performed on a microdrilling process on pure magnesium using a 0.138 mm diameter microdrill to achieve an aspect ratio equal to 36 is proposed. The effect of the variation of the cutting parameters feed per tooth fz and cutting speed vc was studied on thrust force, supporting hole quality evaluation in terms of burr height, entrance, and inner diameters. The results showed that fz significantly influences the hole quality. In fact, as fz increases, the burr height decreases and the inner diameter approaches the nominal diameter. However, optimizing the hole geometry with high feed per tooth values increases the thrust forces, compromising tool life. In fact, a significant dependence of the thrust force on both cutting parameters was found. In this scenario, increasing vc can mitigate the high thrust forces by inducing material softening. The study results improve precision manufacturing by refining parameters, ensuring the quality and reliability of magnesium-based microcomponents.

20 May 2021 in Bioengineering
Verified
Journal Article
Open access
PDF file
MFMarco Ferroni
Marco Ferroni
BBBeatrice Belgio
Beatrice Belgio
GPGiuseppe Michele Peretti
Giuseppe Michele Peretti
AGALESSIA DI GIANCAMILLO
ALESSIA DI GIANCAMILLO
FBFederica Boschetti
Federica Boschetti
The menisci of the knee are complex fibro-cartilaginous tissues that play important roles in load bearing, shock absorption, joint lubrication, and stabilization. The objective of this study was to evaluate the interaction between the different meniscal tissue components (i.e., the solid matrix constituents and the fluid phase) and the mechanical response according to the developmental stage of the tissue. Menisci derived from partially and fully developed pigs were analyzed. We carried out biochemical analyses to quantify glycosaminoglycan (GAG) and DNA content according to the developmental stage. These values were related to tissue mechanical properties that were measured in vitro by performing compression and tension tests on meniscal specimens. Both compression and tension protocols consisted of multi-ramp stress–relaxation tests comprised of increasing strains followed by stress–relaxation to equilibrium. To better understand the mechanical response to different directions of mechanical stimulus and to relate it to the tissue structural composition and development, we performed numerical simulations that implemented different constitutive models (poro-elasticity, viscoelasticity, transversal isotropy, or combinations of the above) using the commercial software COMSOL Multiphysics. The numerical models also allowed us to determine several mechanical parameters that cannot be directly measured by experimental tests. The results of our investigation showed that the meniscus is a non-linear, anisotropic, non-homogeneous material: mechanical parameters increase with strain, depend on the direction of load, and vary among regions (anterior, central, and posterior). Preliminary numerical results showed the predominant role of the different tissue components depending on the mechanical stimulus. The outcomes of biochemical analyses related to mechanical properties confirmed the findings of the numerical models, suggesting a specific response of meniscal cells to the regional mechanical stimuli in the knee joint. During maturation, the increase in compressive moduli could be explained by cell differentiation from fibroblasts to metabolically active chondrocytes, as indicated by the found increase in GAG/DNA ratio. The changes of tensile mechanical response during development could be related to collagen II accumulation during growth. This study provides new information on the changes of tissue structural components during maturation and the relationship between tissue composition and mechanical response.

15 March 2022 in Bioengineering
Verified
Journal Article
Open access
PDF file
LALucia Aidos
Lucia Aidos
SMSilvia Modina
Silvia Modina
VHValentina Herrera
Valentina Herrera
GPGiuseppe Michele Peretti
Giuseppe Michele Peretti
LMLaura Mangiavini
Laura Mangiavini
AGALESSIA DI GIANCAMILLO
ALESSIA DI GIANCAMILLO
The analysis of the morphological, structural, biochemical, and mechanical changes of the Extracellular Matrix (ECM), which occur during meniscus development, represents the goal of the present study. Medial fully developed menisci (FD, 9-month-old pigs), partially developed menisci (PD, 1-month-old piglets), and not developed menisci (ND, from stillbirths) were collected. Cellularity and glycosaminoglycans (GAGs) deposition were evaluated by ELISA, while Collagen 1 and aggrecan were investigated by immunohistochemistry and Western blot analyses in order to be compared to the biomechanical properties of traction and compression tensile forces, respectively. Cellularity decreased from ND to FD and GAGs showed the opposite trend (p < 0.01 both). Collagen 1 decreased from ND to FD, as well as the ability to resist to tensile traction forces (p < 0.01), while aggrecan showed the opposite trend, in accordance with the biomechanics: compression test showed that FD meniscus greatly resists to deformation (p < 0.01). This study demonstrated that in swine meniscus, clear morphological and biomechanical changes follow the meniscal maturation and specialization during growth, starting with an immature pattern (ND) to the mature organized meniscus of the FD, and they could be useful to understand the behavior of this structure in the light of its tissue bioengineering.

3 January 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
Margherita PizziMargherita Pizzi
Margherita Pizzi
FGFrancesco De Gaetano
Francesco De Gaetano
MFMarco Ferroni
Marco Ferroni
FBFederica Boschetti
Federica Boschetti
MAMassimiliano Annoni
Massimiliano Annoni
The mechanisms of deep-hole microdrilling of pure Mg material were experimentally studied in order to find a suitable setup for a novel intraocular drug delivery device prototyping. Microdrilling tests were performed with 0.20 mm and 0.35 mm microdrills, using a full factorial design in which cutting speed vc and feed fz were varied over two levels. In a preliminary phase, the chip shape was evaluated for low feeds per tooth down to 1 μm, to verify that the chosen parameters were appropriate for machining. Subsequently, microdrilling experiments were carried out, in which diameter, burr height and surface roughness of the drilled holes were examined. The results showed that the burr height is not uniform along the circumference of the holes. In particular, the maximum burr height increases with higher cutting speed, due to the thermal effect that plasticizes Mg. Hole entrance diameters are larger than the nominal tool diameters due to tool runout, and their values are higher for high vc and fz. In addition, the roughness of the inner surface of the holes increases as fz increases.