Francesco De Gaetano

Dr. Francesco De Gaetano

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 June 2014 in Soft Matter
Verified
Journal Article
Open access
PDF file
JSJoanna Stasiak
Joanna Stasiak
JBJacob Brubert
Jacob Brubert
MSMarta Serrani
Marta Serrani
SNSukumaran Nair
Sukumaran Nair
FGFrancesco De Gaetano
Francesco De Gaetano
GMGeoff D. Moggridge
Geoff D. Moggridge
A bi-directional, layered microstructure in cylinder forming block copolymers results from the local balance of shear and extensional flow during slow injection moulding.

1 November 2015 in The International Journal of Artificial Organs
Verified
Journal Article
Open access
FGFrancesco De Gaetano
Francesco De Gaetano
MSMarta Serrani
Marta Serrani
PBPaola Bagnoli
Paola Bagnoli
JBJacob Brubert
Jacob Brubert
JSJoanna Stasiak
Joanna Stasiak
MCMaria Laura Costantino
Maria Laura Costantino
Purpose: Only mechanical and biological heart valve prostheses are currently commercially available. The former show longer durability but require anticoagulant therapy; the latter display better fluid dynamic behavior but do not have adequate durability. New Polymeric Heart Valves (PHVs) could potentially combine the hemodynamic properties of biological valves with the durability of mechanical valves. This work presents a hydrodynamic evaluation of 2 groups of newly developed supra-annular, trileaflet prosthetic heart valves made from styrenic block copolymers (SBC): Poli-Valves. Methods: 2 types of Poli-Valves made of SBC and differing in polystyrene fraction content were tested under continuous and pulsatile flow conditions as prescribed by ISO 5840 Standard. A pulse duplicator designed ad hoc allowed the valve prototypes to be tested at different flow rates and frequencies. Pressure and flow were recorded; pressure drops, effective orifice area (EOA), and regurgitant volume were computed to assess the behavior of the valve. Results: Both types of Poli-Valves met the minimum requirements in terms of regurgitation and EOA as specified by the ISO 5840 Standard. Results were compared with 5 mechanical heart valves (MHVs) and 5 tissue heart valves (THVs), currently available on the market. Conclusions: Based on these results, PHVs based on styrenic block copolymers, as are Poli-Valves, can be considered a promising alternative for heart valve replacement in the near future.

9 April 2015 in Journal of Mechanics in Medicine and Biology
Verified
Journal Article
Open access
PDF file
FGFrancesco De Gaetano
Francesco De Gaetano
PBPaola Bagnoli
Paola Bagnoli
AZAdriano Zaffora
Adriano Zaffora
APAnna Pandolfi
Anna Pandolfi
MSMarta Serrani
Marta Serrani
MCMaria Laura Costantino
Maria Laura Costantino
The potential of polymeric heart valves (PHV) prostheses is to combine the hemodynamic performances of biological valves with the durability of mechanical valves. The aim of this work is to design and develop a new tri-leaflet prosthetic heart valve (HV) made from styrenic block copolymers. A computational finite element model was implemented to optimize the thickness of the leaflets, to improve PHV mechanical and hydrodynamic performances. Based on the model outcomes, 8 prototypes of the designed valve were produced and tested in vitro under continuous and pulsatile flow conditions, as prescribed by ISO 5840 Standard. A specially designed pulse duplicator allowed testing the PHVs at different flow rates and frequency conditions. All the PHVs met the requirements specified in ISO 5840 Standard in terms of both regurgitation and effective orifice area (EOA), demonstrating their potential as HV prostheses.

8 July 2020 in Medical Engineering & Physics
Verified
Journal Article
Closed access
MFMarco Ferroni
Marco Ferroni
FGFrancesco De Gaetano
Francesco De Gaetano
MCMatteo Giuseppe Cereda
Matteo Giuseppe Cereda
FBFederica Boschetti
Federica Boschetti
The purpose of this study is to investigate the effect of vitreous sloshing induced by saccades on the intravitreal delivery of large molecule drugs. The vitreous body was considered in its age-related liquefaction condition. Fluid dynamics and large molecule distribution were described by the coupling of mass conservation's and Fick's laws with continuity and momentum equations for a Newtonian incompressible fluid in a 3D unsteady analysis. Two injection sites were analyzed, in both the mixing effect of a 50° periodic saccade leads to uniform drug distribution in 30 s of simulation, the initial bolus site being left after 3 s of simulation. In absence of saccadic movements, the dominant transport contribution is the diffusive one and large molecules hardly reach their uniform distribution inside the vitreous cavity. A model describing the intravitreal distribution of large molecules in presence of saccades was developed, improving the understanding of drug transport mechanism after an intravitreal injection and highlighting how advection contribution enhances its distribution in the vitreous chamber.

23 June 2024 in Micromachines
Verified
Journal Article
Open access
PDF file
Margherita PizziMargherita Pizzi
Margherita Pizzi
ACAntonio Costetti
Antonio Costetti
FGFrancesco De Gaetano
Francesco De Gaetano
MFMarco Ferroni
Marco Ferroni
FAFrancesco Arleo
Francesco Arleo
MAMassimiliano Annoni
Massimiliano Annoni
Size effects, high thrust forces, limited heat dissipation, and tool deterioration are just some of the challenges that deep microdrilling poses, underscoring the importance of effective process control to ensure quality. In this paper, an investigation performed on a microdrilling process on pure magnesium using a 0.138 mm diameter microdrill to achieve an aspect ratio equal to 36 is proposed. The effect of the variation of the cutting parameters feed per tooth fz and cutting speed vc was studied on thrust force, supporting hole quality evaluation in terms of burr height, entrance, and inner diameters. The results showed that fz significantly influences the hole quality. In fact, as fz increases, the burr height decreases and the inner diameter approaches the nominal diameter. However, optimizing the hole geometry with high feed per tooth values increases the thrust forces, compromising tool life. In fact, a significant dependence of the thrust force on both cutting parameters was found. In this scenario, increasing vc can mitigate the high thrust forces by inducing material softening. The study results improve precision manufacturing by refining parameters, ensuring the quality and reliability of magnesium-based microcomponents.

3 January 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
Margherita PizziMargherita Pizzi
Margherita Pizzi
FGFrancesco De Gaetano
Francesco De Gaetano
MFMarco Ferroni
Marco Ferroni
FBFederica Boschetti
Federica Boschetti
MAMassimiliano Annoni
Massimiliano Annoni
The mechanisms of deep-hole microdrilling of pure Mg material were experimentally studied in order to find a suitable setup for a novel intraocular drug delivery device prototyping. Microdrilling tests were performed with 0.20 mm and 0.35 mm microdrills, using a full factorial design in which cutting speed vc and feed fz were varied over two levels. In a preliminary phase, the chip shape was evaluated for low feeds per tooth down to 1 μm, to verify that the chosen parameters were appropriate for machining. Subsequently, microdrilling experiments were carried out, in which diameter, burr height and surface roughness of the drilled holes were examined. The results showed that the burr height is not uniform along the circumference of the holes. In particular, the maximum burr height increases with higher cutting speed, due to the thermal effect that plasticizes Mg. Hole entrance diameters are larger than the nominal tool diameters due to tool runout, and their values are higher for high vc and fz. In addition, the roughness of the inner surface of the holes increases as fz increases.