Peng Kuang

Dr. Peng Kuang

Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2016 in Journal of Nuclear Materials
Verified
Journal Article
Closed access
YGY.H. Gong
Y.H. Gong
Xingzhong CaoXingzhong Cao
Xingzhong Cao
SJShuoxue Jin
Shuoxue Jin
ELE.Y. Lu
E.Y. Lu
YHY.C. Hu
Y.C. Hu
BWB.Y. Wang
B.Y. Wang

3 May 2022 in Journal of Nuclear Materials
Verified
Journal Article
Closed access
ZWZhen Wang
Zhen Wang
DXDetao Xiao
Detao Xiao
TZTe Zhu
Te Zhu
YSYamin Song
Yamin Song
YLYongli Liu
Yongli Liu
HWHaibiao Wu
Haibiao Wu

23 December 2022 in Materials
Verified
Journal Article
Open access
PDF file
天王天骄 王
天骄 王
Te ZhuTe Zhu
Te Zhu
DWDandan Wang
Dandan Wang
PZPeng Zhang
Peng Zhang
YSYamin Song
Yamin Song
Xingzhong CaoXingzhong Cao
Xingzhong Cao
In this work, we studied the evolution of vacancy-like defects and the formation of brittle precipitates in a reduced-activation V−Cr−Mn medium-entropy alloy. The evolution of local electronic circumstances around Cr and Mn enrichments, the vacancy defects, and the CrMn3 precipitates were characterized by using scanning electron microscopy with energy-dispersive spectroscopy, X-ray diffraction, and positron annihilation spectroscopy. The microstructure measurements showed that the Mn and Cr enrichments in the as-cast sample significantly evolved with temperature, i.e., from 400 °C, the Cr/Mn-segregated regions gradually dissolved into the matrix and then disappeared, and from 900 °C to 1000 °C, they existed as CrMn3 precipitates. The crystallite size of the phase corresponding to CrMn3 precipitates was about 29.4 nm at 900 °C and 43.7 nm at 1000 °C. The positron annihilation lifetime results demonstrated that the vacancies mediated the migration of Cr and Mn, and Cr and Mn segregation finally led to the formation of CrMn3 precipitates. The coincidence Doppler broadening results showed that the characteristic peak moved to the low-momentum direction, due to an increase in the size of the vacancy defects at the interface and the formation of CrMn3 precipitates.

1 April 2018 in International Journal of Electrochemical Science
Verified
Journal Article
Open access
XCXiang Chen
Xiang Chen
Peng KuangPeng Kuang
Peng Kuang
CCChunguang Chen
Chunguang Chen
XZXiuhui Zhang
Xiuhui Zhang
THTao Huang
Tao Huang
AYAishui Yu
Aishui Yu

28 May 2026 in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
Verified
Journal Article
Closed access
HZH.Q. Zhang
H.Q. Zhang
Peng KuangPeng Kuang
Peng Kuang
FLF.Y. Liu
F.Y. Liu
YHY.H. Hu
Y.H. Hu
XCX.Z. Cao
X.Z. Cao
BWB.Y. Wang
B.Y. Wang

1 January 2021 in IOP Conference Series: Earth and Environmental Science
Verified
Conference Paper
Open access
LRLijun Ren
Lijun Ren
Bin MaBin Ma
Bin Ma
GLGuohong Liu
Guohong Liu
JLJian Li
Jian Li
YXYanhua Xiao
Yanhua Xiao
Peng KuangPeng Kuang
Peng Kuang
Cyanide pollution refers to the environmental pollution caused by cyanide and its compounds. As a derivative of cyanide, the leakage and excessive discharge of hydrogen cyanide will cause great harm to the surrounding animal and plant environment. Rapid detection of hydrogen cyanide can avoid some unnecessary environmental pollution. Based on the principle of non dispersive infrared(NDIR) detection, the infrared absorption of hydrogen cyanide at 3.0 μm and 14.3 μm was selected as the qualitative and quantitative basis. Two NDIR sensors were designed to detect 3.0 μm and 14.3 μm infrared absorption respectively after assembly. The standard curve between the concentration of hydrogen cyanide and the voltage response value was determined, and the performance of the two sensors was tested. Their detection ranges is 10ppm-3000ppm and 22ppm-3000ppm respectively. The maximum response time is less than 11s and RSD < 2%. After comparing the performance of the two sensors, the display values of the different sensors were processed. Finally, the two sensors were assembled into one sensor, the hydrogen cyanide concentration was displayed with one indication and different gases were mixed with hydrogen cyanide to pass into the gas chamber, which improved the anti-interference ability.