Oleksandr Grynko

Dr. Oleksandr Grynko

Lakehead University, Thunder Bay, Ontario, Canada
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 May 2017 in The Journal of Physical Chemistry C
Verified
Journal Article
Closed access
CSC. P. Saini
C. P. Saini
ABA. Barman
A. Barman
DBD. Banerjee
D. Banerjee
OGOleksandr Grynko
Oleksandr Grynko
SPS. Prucnal
S. Prucnal
AKA. Kanjilal
A. Kanjilal

17 August 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
OSO. Semeniuk
O. Semeniuk
OGOleksandr Grynko
Oleksandr Grynko
GDG. Decrescenzo
G. Decrescenzo
GJG. Juska
G. Juska
KWKai Wang
Kai Wang
ARA. Reznik
A. Reznik
While polycrystalline lead oxide (poly-PbO) is known to be one of the most promising photoconductors for utilization in X-ray detectors, its major performance parameters such as charge yield and mobility-lifetime product (μτ) are still not well established and require further investigation. Combining the conventional X-ray induced photocurrent and pulse height spectroscopy techniques we examine the X-ray photogeneration and recombination processes in poly-PbO. The measurements indicate that the amount of energy required to release a single electron hole pair W± (inverse of charge yield) strongly depends on applied electric field and at 10 V/μm reaches ~20 eV/ehp. Fitting the measured pulse height spectra with the Hecht formula provided μτ for holes and electrons to be 4.1 × 10−8 cm2/V and 10−9 cm2/V, respectively. Obtained μτ values combined with recently reported mobility values of charge carriers in PbO suggest a new direction towards improvement of PbO technology by incorporation of Frisch grid or X-ray transistor architectures.

16 October 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
OSO. Semeniuk
O. Semeniuk
OGOleksandr Grynko
Oleksandr Grynko
GJG. Juska
G. Juska
ARA. Reznik
A. Reznik
Presence of a signal lag is a bottle neck of performance for many non-crystalline materials, considered for dynamic radiation sensing. Due to inadequate lag-related temporal performance, polycrystalline layers of CdZnTe, PbI2, HgI2 and PbO are not practically utilized, despite their superior X-ray sensitivity and low production cost (even for large area detectors). In the current manuscript, we show that a technological step to replace nonhomogeneous disorder in polycrystalline PbO with homogeneous amorphous PbO structure suppresses signal lag and improves time response to X-ray irradiation. In addition, the newly developed amorphous lead oxide (a-PbO) possesses superior X-ray sensitivity in terms of electron-hole pair creation energy $${W}_{\pm }$$ W ± in comparison with amorphous selenium – currently the only photoconductor used as an X-ray-to-charge transducer in the state-of-the-art direct conversion X-ray medical imaging systems. The proposed advances of the deposition process are low cost, easy to implement and with certain customization might potentially be applied to other materials, thus paving the way to their wide-range commercial use.

29 March 2021 in IEEE Transactions on Electron Devices
Verified
Journal Article
Open access
OGOleksandr Grynko
Oleksandr Grynko
TTTristen Thibault
Tristen Thibault
EPEmma Pineau
Emma Pineau
ARAlla Reznik
Alla Reznik
Direct conversion flat panel detectors are of great significance to the field of medical X-ray imaging since they offer imaging performance and diagnostic capabilities not achievable with other methods. Currently, mammographic direct conversion detectors employ a layer of amorphous selenium (a-Se) photoconductor. Although its properties ideally fit the requirements of mammography, where “soft” X-rays are used, a-Se cannot be used in high-energy X-ray procedures. To extend the diagnostic capabilities of the direct conversion detectors, amorphous lead oxide (a-PbO) is proposed as an alternative photoconductor. It is a high effective atomic number material and thus has a higher X-ray stopping power over the wide X-ray energy range. a-PbO is, therefore, a suitable candidate for applications in radiography, fluoroscopy, and digital tomosynthesis. Here, we report on the development of a blocking structure with a polyimide (PI) layer needed to maintain low dark current at high electric fields. We demonstrate that a 1- μm-thick PI blocking layer allows the operation of the detector at strong electric fields (≥10 V/ μm) while suppressing the dark current to an innocuous level (<; 1 pA/mm 2 ). It also improves temporal performance by reducing signal lag. No ghosting effect was observed at exposure rates up to 1 R/s; however, at high radiation levels, the detector's sensitivity degraded. This degradation is not permanent as the detector restores its original sensitivity after several hours of rest in the dark without bias applied.

18 November 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
OGOleksandr Grynko
Oleksandr Grynko
TTTristen Thibault
Tristen Thibault
EPEmma Pineau
Emma Pineau
GJGytis Juska
Gytis Juska
ARAlla Reznik
Alla Reznik
Polycrystalline Lead Oxide (poly-PbO) was considered one of the most promising photoconductors for the direct conversion X-ray medical imaging detectors due to its previous success in optical imaging, i.e., as an optical target in so-called Plumbicon video pick-up tubes. However, a signal lag which accompanies X-ray excitation, makes poly-PbO inapplicable as an X-ray-to-charge transducer in real-time X-ray imaging. In contrast, the recently synthesized Amorphous Lead Oxide (a-PbO) photoconductor is essentially lag-free. Here, we report on our approach to a PbO detector where a thin layer of a-PbO is combined with a thick layer of poly-PbO for lag-free operation. In the presented a-PbO/poly-PbO bilayer structure, the poly-PbO layer serves as an X-ray-to-charge transducer while the a-PbO acts as a lag prevention layer. The hole mobility in the a-PbO/poly-PbO bilayer structure was measured by photo-Charge Extraction by Linearly Increasing Voltage technique at different temperatures and electric fields to investigate charge transport properties. It was found that the hole mobility is similar to that in a-Se—currently the only commercially viable photoconductor for the direct conversion X-ray detectors. Evaluation of the X-ray temporal performance demonstrated complete suppression of signal lag, allowing operation of the a-PbO/poly-PbO detector in real-time imaging.

3 November 2021 in Sensors
Verified
Journal Article
Open access
PDF file
OGOleksandr Grynko
Oleksandr Grynko
TTTristen Thibault
Tristen Thibault
EPEmma Pineau
Emma Pineau
ARAlla Reznik
Alla Reznik
The photoconductor layer is an important component of direct conversion flat panel X-ray imagers (FPXI); thus, it should be carefully selected to meet the requirements for the X-ray imaging detector, and its properties should be clearly understood to develop the most optimal detector design. Currently, amorphous selenium (a-Se) is the only photoconductor utilized in commercial direct conversion FPXIs for low-energy mammographic imaging, but it is not practically feasible for higher-energy diagnostic imaging. Amorphous lead oxide (a-PbO) photoconductor is considered as a replacement to a-Se in radiography, fluoroscopy, and tomosynthesis applications. In this work, we investigated the X-ray sensitivity of a-PbO, one of the most important parameters for X-ray photoconductors, and examined the underlying mechanisms responsible for charge generation and recombination. The X-ray sensitivity in terms of electron–hole pair creation energy, W±, was measured in a range of electric fields, X-ray energies, and exposure levels. W± decreases with the electric field and X-ray energy, saturating at 18–31 eV/ehp, depending on the energy of X-rays, but increases with the exposure rate. The peculiar dependencies of W± on these parameters lead to a conclusion that, at electric fields relevant to detector operation (~10 V/μm), the columnar recombination and the bulk recombination mechanisms interplay in the a-PbO photoconductor.