The aim of this study is to evaluate the performance of the Radialis organ-targeted positron emission tomography (PET) Camera with standardized tests and through assessment of clinical-imaging results. Sensitivity, count-rate performance, and spatial resolution were evaluated according to the National Electrical Manufacturers Association (NEMA) NU-4 standards, with necessary modifications to accommodate the planar detector design. The detectability of small objects was shown with micro hotspot phantom images. The clinical performance of the camera was also demonstrated through breast cancer images acquired with varying injected doses of 2-[fluorine-18]-fluoro-2-deoxy-D-glucose (18F-FDG) and qualitatively compared with sample digital full-field mammography, magnetic resonance imaging (MRI), and whole-body (WB) PET images. Micro hotspot phantom sources were visualized down to 1.35 mm-diameter rods. Spatial resolution was calculated to be 2.3 ± 0.1 mm for the in-plane resolution and 6.8 ± 0.1 mm for the cross-plane resolution using maximum likelihood expectation maximization (MLEM) reconstruction. The system peak noise equivalent count rate was 17.8 kcps at a 18F-FDG concentration of 10.5 kBq/mL. System scatter fraction was 24%. The overall efficiency at the peak noise equivalent count rate was 5400 cps/MBq. The maximum axial sensitivity achieved was 3.5%, with an average system sensitivity of 2.4%. Selected results from clinical trials demonstrate capability of imaging lesions at the chest wall and identifying false-negative X-ray findings and false-positive MRI findings, even at up to a 10-fold dose reduction in comparison with standard 18F-FDG doses (i.e., at 37 MBq or 1 mCi). The evaluation of the organ-targeted Radialis PET Camera indicates that it is a promising technology for high-image-quality, low-dose PET imaging. High-efficiency radiotracer detection also opens an opportunity to reduce administered doses of radiopharmaceuticals and, therefore, patient exposure to radiation.
Lead oxide (PbO) photoconductors are proposed as X-ray-to-charge transducers for the next generation of direct conversion digital X-ray detectors. Optimized PbO-based detectors have potential for utilization in high-energy and dynamic applications of medical X-ray imaging. Two polymorphs of PbO have been considered so far for imaging applications: polycrystalline lead oxide (poly-PbO) and amorphous lead oxide (a-PbO). Here, we provide the comparative analysis of two PbO-based single-pixel X-ray detector prototypes: one prototype employs only a layer of a-PbO as the photoconductor while the other has a combination of a-PbO and poly-PbO, forming a photoconductive bilayer structure of the same overall thickness as in the first prototype. We characterize the performance of these prototypes in terms of electron–hole creation energy (W±) and signal lag—major properties that define a material’s suitability for low-dose real-time imaging. The results demonstrate that both X-ray photoconductive structures have an adequate temporal response suitable for real-time X-ray imaging, combined with high intrinsic sensitivity. These results are discussed in the context of structural and morphological properties of PbO to better understand the preparation–fabrication–property relationships of this material.
The photoconductor layer is an important component of direct conversion flat panel X-ray imagers (FPXI); thus, it should be carefully selected to meet the requirements for the X-ray imaging detector, and its properties should be clearly understood to develop the most optimal detector design. Currently, amorphous selenium (a-Se) is the only photoconductor utilized in commercial direct conversion FPXIs for low-energy mammographic imaging, but it is not practically feasible for higher-energy diagnostic imaging. Amorphous lead oxide (a-PbO) photoconductor is considered as a replacement to a-Se in radiography, fluoroscopy, and tomosynthesis applications. In this work, we investigated the X-ray sensitivity of a-PbO, one of the most important parameters for X-ray photoconductors, and examined the underlying mechanisms responsible for charge generation and recombination. The X-ray sensitivity in terms of electron–hole pair creation energy, W±, was measured in a range of electric fields, X-ray energies, and exposure levels. W± decreases with the electric field and X-ray energy, saturating at 18–31 eV/ehp, depending on the energy of X-rays, but increases with the exposure rate. The peculiar dependencies of W± on these parameters lead to a conclusion that, at electric fields relevant to detector operation (~10 V/μm), the columnar recombination and the bulk recombination mechanisms interplay in the a-PbO photoconductor.
The reduction of the dark current (DC) to a tolerable level in amorphous selenium (a-Se) X-ray photoconductors was one of the key factors that led to the successful commercialization of a-Se-based direct conversion flat panel X-ray imagers (FPXIs) and their widespread clinical use. Here, we discuss the origin of DC in another X-ray photoconductive structure that utilizes amorphous lead oxide (a-PbO) as an X-ray-to-charge transducer and polyimide (PI) as a blocking layer. The transient DC in a PI/a-PbO detector is measured at different applied electric fields (5–20 V/μm). The experimental results are used to develop a theoretical model describing the electric field-dependent transient behavior of DC. The results of the DC kinetics modeling show that the DC, shortly after the bias application, is primarily controlled by the injection of holes from the positively biased electrode and gradually decays with time to a steady-state value. DC decays by the overarching mechanism of an electric field redistribution, caused by the accumulation of trapped holes in deep localized states within the bulk of PI. Thermal generation and subsequent multiple-trapping (MT) controlled transport of holes within the a-PbO layer governs the steady-state value at all the applied fields investigated here, except for the largest applied field of 20 V/μm. This suggests that a thicker layer of PI would be more optimal to suppress DC in the PI/a-PbO detector presented here. The model can be used to find an approximate optimal thickness of PI for future iterations of PI/a-PbO detectors without the need for time and labor-intensive experimental trial and error. In addition, we show that accounting for the field-induced charge carrier release from traps, enhanced by charge hopping transitions between the traps, yields an excellent fit between the experimental and simulated results, thus, clarifying the dynamic process of reaching a steady-state occupancy level of the deep localized states in the PI. Practically, the electric field redistribution causes the internal field to increase in magnitude in the a-PbO layer, thus improving charge collection efficiency and temporal performance over time, as confirmed by experimental results. The electric field redistribution can be implemented as a warm-up time for a-PbO-based detectors.
Background: The asymmetric distribution of optical photons near the edges of Positron Emission Tomography (PET) sensor modules introduces errors in the coordinate reconstruction of scintillation events when center-of-gravity (CoG) algorithms are utilized. This issue, sometimes referred to as the “edge effect”, results in overlap of crystal pixel signatures in flood maps and potential image artifacts in reconstructed PET images. Methods: Partly segmented 5 mm thick borosilicate light guides with slits cut parallel to the edges are filled with barium sulfate to restrict the spread of optical photons near the edges of the light guide. Data acquisitions are performed using single PET sensor modules in coincidence, both with single and multiplexed channel readout. CoG and truncated center-of-gravity (TCoG) methods are used for coordinate reconstruction. Results: A 22 × 22 array of crystal signatures are distinguishable on crystal flood maps produced using sensor modules with solid light guides and 24 × 24 arrays can be identified when using a partly segmented light guide. The pixel resolution around the edges and corners of the flood map is further improved when TCoG is used for coordinate reconstruction. Summary: We show that the introduction of a partly segmented light guide greatly improves coordinate reconstruction accuracy at the edges of a sensor module. In addition, it is demonstrated that the partly segmented light guides can be used in parallel with other proposed methods designed to fix the “edge effect”, including TCoG, to further coordinate reconstruction improve accuracy and crystal flood map quality.
Amorphous lead oxide (a-PbO) X-ray photoconductors show potential for applications in direct conversion medical imaging detectors within the diagnostic energy range. a-PbO enables large-area deposition at low temperatures and exhibits no signal lag. Low dark current can be maintained through specialized blocking layers, similar to those used in multilayer amorphous selenium (a-Se) structures in commercial detectors. However, the current state of a-PbO technology faces challenges in thick layer deposition, leading to crystalline inclusions and cracks. Our proposed stress-induced crystallization model reveals that intrinsic stress in a-PbO layers amplifies with thickness, leading to crystallographic defects. These defects, which are associated with the stable phase of β-PbO, contribute to increased dark current and initiate layer cracking. We calculate the thermal expansion coefficient of a-PbO, indicating a thermomechanical mismatch between the photoconductor and the substrate as the primary source of stress. Furthermore, we demonstrate that layer deposition parameters significantly impact heat accumulation within the growing layer, thereby facilitating temperature-induced crystallization. Our study suggests that relieving stress in grown a-PbO layers by eliminating thermal expansion coefficient mismatches between different layers in a-PbO blocking structures, coupled with optimizing deposition parameters to prevent heat accumulation during layer growth, may inhibit or even prevent stress-induced crystallization and the emergence of structural defects in thick a-PbO layers.