Paweł Borkowski

Dr. Paweł Borkowski

orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 March 2013 in Biomechanics and Modeling in Mechanobiology
Verified
Journal Article
Open access
PDF file
MKMonika Kwacz
Monika Kwacz
Piotr MarekPiotr Marek
Piotr Marek
PBPaweł Borkowski
Paweł Borkowski
MMMaciej Mrówka
Maciej Mrówka
Piston stapes prostheses are implanted in patients with refractory conductive or mixed hearing loss due to stapes otosclerosis to stimulate the perilymph with varying degrees of success. The overclosure effect described by the majority of researchers affects mainly low and medium frequencies, and a large number of patients report a lack of satisfactory results for frequencies above 2 kHz. The mechanics of perilymph stimulation with the piston have not been studied in a systematic manner. The objective of this study was to assess the influence of stapedotomy surgery on round window membrane vibration and to estimate the postoperative outcomes using the finite element (FE) method. The study hypothesis is that the three-dimensional FE model developed of the human inner ear, which simulates the round window (RW) membrane vibration, can be used to assess the influence of stapedotomy on auditory outcomes achieved after the surgical procedure. An additional objective of the study was to enable the simulation of RW membrane vibration after stapedotomy using a new type of stapes prosthesis currently under investigation at Warsaw University of Technology. A three-dimensional finite element (FE) model of the human inner ear was developed and validated using experimental data. The model was then used to simulate the round window membrane vibration before and after stapedotomy surgery. Functional alterations of the RW membrane vibration were derived from the model and compared with the results of experimental measurements from temporal bones of a human cadaver. Piston stapes prosthesis implantation causes an approximately fivefold (14 dB) lower amplitude of the RW membrane vibrations compared with normal anatomical conditions. A satisfactory agreement between the FE model and the experimental data was found. The new prosthesis caused an increase of 20–30 dB in the RW displacement amplitude compared with the 0.4-mm piston prosthesis. In all frequencies, the FE model predicted a RW displacement curve that was above the experimental curves for the normal ear. The stapedotomy can be well simulated by the FE model to predict the auditory outcomes achieved following this otosurgery procedure. The 3D FE model developed in this study may be used to optimize the geometry of a new type of stapes prosthesis in order to achieve a similar sound transmission through the inner ear as for a normal middle ear. This should provide better auditory outcomes for patients with stapedial otosclerosis.

1 April 2014 in Hearing Research
Verified
Journal Article
Closed access
MKMonika Kwacz
Monika Kwacz
Piotr MarekPiotr Marek
Piotr Marek
PBPaweł Borkowski
Paweł Borkowski
WGWiktor Gambin
Wiktor Gambin

8 January 2010 in International Journal of Occupational Safety and Ergonomics
Verified
Journal Article
Closed access
JKJoanna Kamińska
Joanna Kamińska
DRDanuta Roman-Liu
Danuta Roman-Liu
TZTomasz Zagrajek
Tomasz Zagrajek
PBPaweł Borkowski
Paweł Borkowski
As the lumbar region of the spine is particularly predisposed to musculoskeletal disorders, the aim of this article was to assess lumbar spine load on the basis of an accurate model of this part of the body. The model was developed with the finite element method and the energy criterion for optimising muscle work. Computer calculations confirmed that stresses and compression forces in intervertebral discs increased with an increase in the load force and that they were significantly larger in the bent forwards posture than in the erect posture. This result clearly shows that lifting light objects and the erect posture are important elements in minimising spine load.

1 January 2019
Verified
Journal Article
Closed access
PBPaweł Borkowski
Paweł Borkowski
Piotr MarekPiotr Marek
Piotr Marek
KNKazimierz Niemczyk
Kazimierz Niemczyk
MLMagdalena Lachowska
Magdalena Lachowska
MKMonika Kwacz
Monika Kwacz
JWJaroslaw Wysocki
Jaroslaw Wysocki

1 March 2016 in Archive of Mechanical Engineering
Verified
Journal Article
Open access
PDF file
PBPaweł Borkowski
Paweł Borkowski
DGDominik Głowacki
Dominik Głowacki
ANAgnieszka Nowakowska
Agnieszka Nowakowska
JPJakub Pawlicki
Jakub Pawlicki
JZJanisław Zwolinski
Janisław Zwolinski
This paper is concerned with the 1st stage of HP rotor blade assembly steam turbine TK 120. The methodology was focused on the selection of mechanical properties and the way of the rotor disc modeling and estimating the degree of damage caused by creep. Then the dynamic interference between the frequencies of excitation and the natural frequencies was assessed. Static calculations were performed for the cyclic sectors consisting of the disc, disc blades, spacers and shrouding, including loads as temperature, mass forces from the angular velocity and the pressure on the blades. Then, the creep analysis using a Norton’s model and the modal analysis were performed. Static analysis gave information concerning the distributions of displacements, stress and strain components. In the creep analysis, the creep displacements and stress relaxation versus time were determined and the estimated degree of damage caused by creep was evaluated at each part of the rotor disc. In the modal analysis, the natural frequencies and modes of vibrations corresponding to the nodal diameters were found. The results of modal analysis were shown in the SAFE graph. Numerical calculations have shown that the rotor disc was a well-designed structure and did not reveal any dynamic interference.

1 January 2012
Verified
Journal Article
Closed access
PBPaweł Borkowski
Paweł Borkowski
Piotr MarekPiotr Marek
Piotr Marek
GKG Krzesiński
G Krzesiński
Joanna RyszkowskaJoanna Ryszkowska
Joanna Ryszkowska
BWB Waśniewski
B Waśniewski
TZT Zagrajek
T Zagrajek