Monika Kwacz

Monika Kwacz


Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 March 2013 in Biomechanics and Modeling in Mechanobiology
Verified
Journal Article
Open access
PDF file
MKMonika Kwacz
Monika Kwacz
Piotr MarekPiotr Marek
Piotr Marek
PBPaweł Borkowski
Paweł Borkowski
MMMaciej Mrówka
Maciej Mrówka
Piston stapes prostheses are implanted in patients with refractory conductive or mixed hearing loss due to stapes otosclerosis to stimulate the perilymph with varying degrees of success. The overclosure effect described by the majority of researchers affects mainly low and medium frequencies, and a large number of patients report a lack of satisfactory results for frequencies above 2 kHz. The mechanics of perilymph stimulation with the piston have not been studied in a systematic manner. The objective of this study was to assess the influence of stapedotomy surgery on round window membrane vibration and to estimate the postoperative outcomes using the finite element (FE) method. The study hypothesis is that the three-dimensional FE model developed of the human inner ear, which simulates the round window (RW) membrane vibration, can be used to assess the influence of stapedotomy on auditory outcomes achieved after the surgical procedure. An additional objective of the study was to enable the simulation of RW membrane vibration after stapedotomy using a new type of stapes prosthesis currently under investigation at Warsaw University of Technology. A three-dimensional finite element (FE) model of the human inner ear was developed and validated using experimental data. The model was then used to simulate the round window membrane vibration before and after stapedotomy surgery. Functional alterations of the RW membrane vibration were derived from the model and compared with the results of experimental measurements from temporal bones of a human cadaver. Piston stapes prosthesis implantation causes an approximately fivefold (14 dB) lower amplitude of the RW membrane vibrations compared with normal anatomical conditions. A satisfactory agreement between the FE model and the experimental data was found. The new prosthesis caused an increase of 20–30 dB in the RW displacement amplitude compared with the 0.4-mm piston prosthesis. In all frequencies, the FE model predicted a RW displacement curve that was above the experimental curves for the normal ear. The stapedotomy can be well simulated by the FE model to predict the auditory outcomes achieved following this otosurgery procedure. The 3D FE model developed in this study may be used to optimize the geometry of a new type of stapes prosthesis in order to achieve a similar sound transmission through the inner ear as for a normal middle ear. This should provide better auditory outcomes for patients with stapedial otosclerosis.

4 June 2015 in Journal of the Association for Research in Otolaryngology
Verified
Journal Article
Closed access
PDF file
MKMonika Kwacz
Monika Kwacz
ZRZygmunt Rymuza
Zygmunt Rymuza
MMMarcin Michałowski
Marcin Michałowski
JWJarosław Wysocki
Jarosław Wysocki

1 April 2014 in Hearing Research
Verified
Journal Article
Closed access
MKMonika Kwacz
Monika Kwacz
Piotr MarekPiotr Marek
Piotr Marek
PBPaweł Borkowski
Paweł Borkowski
WGWiktor Gambin
Wiktor Gambin

16 August 2011 in The Laryngoscope
Verified
Journal Article
Closed access
PDF file
JWJarosław Wysocki
Jarosław Wysocki
MKMonika Kwacz
Monika Kwacz
MMMaciej Mrówka
Maciej Mrówka
Henryk SkarzynskiHenryk Skarzynski
Henryk Skarzynski

1 March 2000 in Wear
Verified
Journal Article
Closed access
ZRZ. Rymuza
Z. Rymuza
ZKZ. Kusznierewicz
Z. Kusznierewicz
TST. Solarski
T. Solarski
MKMonika Kwacz
Monika Kwacz
SCS.A. Chizhik
S.A. Chizhik
AGA.V. Goldade
A.V. Goldade

1 January 2012 in Biocybernetics and Biomedical Engineering
Verified
Journal Article
Closed access
MKMonika Kwacz
Monika Kwacz
JWJaroslaw Wysocki
Jaroslaw Wysocki
PKPiotr Krakowian
Piotr Krakowian