Dissolved gas analysis (DGA) is attracting greater and greater interest from researchers as a fault diagnostic tool for power transformers filled with vegetable insulating oils. This paper presents experimental results of dissolved gases in insulating oils under typical electrical and thermal faults in transformers. The tests covered three types of insulating oils, including two types of vegetable oil, which are camellia insulating oil, Envirotemp FR3, and a type of mineral insulating oil, to simulate thermal faults in oils from 90 °C to 800 °C and electrical faults including breakdown and partial discharges in oils. The experimental results reveal that the content and proportion of dissolved gases in different types of insulating oils under the same fault condition are different, especially under thermal faults due to the obvious differences of their chemical compositions. Four different classic diagnosis methods were applied: ratio method, graphic method, and Duval’s triangle and Duval’s pentagon method. These confirmed that the diagnosis methods developed for mineral oil were not fully appropriate for diagnosis of electrical and thermal faults in vegetable insulating oils and needs some modification. Therefore, some modification aiming at different types of vegetable oils based on Duval Triangle 3 were proposed in this paper and obtained a good diagnostic result. Furthermore, gas formation mechanisms of different types of vegetable insulating oils under thermal stress are interpreted by means of unimolecular pyrolysis simulation and reaction enthalpies calculation.
Nanoparticles enhance the electrical insulation and thermal properties of vegetable oil, and such improvements are desirable for its application as an alternative to traditional insulating oil for power transformers. However, the traditional method of insulating nanofluids typically achieves high electrical insulation but low thermal conductivity. This work reports an environmentally friendly vegetable oil using exfoliated hexagonal boron nitride (h-BN) showing high thermal conductivity and high electrical insulation. Stable nanofluids were prepared by liquid exfoliation of h-BN in isopropyl alcohol. With 0.1 vol.% of the nano-oil, the AC breakdown voltage increased by 18% at 25°C and 15% at 90°C. Both the positive and negative lightning impulse breakdown voltages of the nano-oil were also enhanced compared with those of the pure oil. Moreover, the thermal conductivity of the nano-oil increased by 11.9% at 25°C and 14% at 90°C. Given its high thermal conductivity, the nano-oil exhibited faster heating and cooling effects than the pure oil. Nano-oils with an electric field (either DC or AC) displayed a faster thermal response than that without an electric field. The reason is that h-BN is oriented under the electric field and formed a thermal network to increase the heat transfer.
The construction of large-scale wind farms results in a dramatic increase of wind turbine (WT) faults. The failure mode is also becoming increasingly complex. This study proposes a new model for early warning and diagnosis of WT faults to solve the problem of Supervisory Control And Data Acquisition (SCADA) systems, given that the traditional threshold method cannot provide timely warning. First, the characteristic quantity of fault early warning and diagnosis analyzed by clustering analysis can obtain in advance abnormal data in the normal threshold range by considering the effects of wind speed. Based on domain knowledge, Adaptive Neuro-fuzzy Inference System (ANFIS) is then modified to establish the fault early warning and diagnosis model. This approach improves the accuracy of the model under the condition of absent and sparse training data. Case analysis shows that the effect of the early warning and diagnosis model in this study is better than that of the traditional threshold method.
Transformer load is a key factor influencing its aging and service life. Accurately predicting load trends is crucial for assisting load redistribution. This study proposes a hybrid model called RIME-VMD-TCN-iTransformer to forecast the trend of transformer load. In this model, RIME (Randomized Improved Marine Predators Algorithm) is employed to enhance decomposition stability, VMD (Variational Mode Decomposition) is used to address the non-stationary characteristics of the load sequence, TCN (Temporal Convolutional Network) extracts local temporal dependencies, and iTransformer (Inverted Transformer) captures global inter-variable correlations. First, the variational mode decomposition algorithm is applied to mitigate the non-stationary characteristics of the signal, followed by the RIME to further enhance the orderliness of the intrinsic mode functions. Subsequently, the TCN-iTransformer model is utilized to predict each intrinsic mode function individually, and the prediction results of all intrinsic mode functions are reconstructed to obtain the final forecast. The findings indicate that the intrinsic mode functions obtained through RIME-VMD exhibit no spectral aliasing and can decompose abrupt time-series signals into stable and regular frequency components. Compared to other hybrid models, the proposed model demonstrates superior responsiveness to changes in time-series trends and achieves the lowest prediction error across various transformer capacity scenarios. These results highlight the model’s superior accuracy and generalization capability in handling abrupt signals, underscoring its potential for preventing unexpected transformer events.
1 February 2022 in Computational Intelligence and Neuroscience
The forecast error characteristic analysis of short-term photovoltaic power generation can provide a reliable reference for power system optimal dispatching. In this paper, the total in-day error level was stratified by fuzzy C-means algorithm. Then the historical PV output data based on the numerical characteristics of point prediction output were classified. A General Gauss Mixed Model was proposed to fit the forecast error distribution of various photovoltaic output forecast error distribution. The impact of meteorological factors together with numerical characteristics on the forecast error was taken into full consideration in this analysis method. The predicted point output with high volatility can be accurately captured, and the reliable confidence interval is given. The proposed method is independent of the point prediction algorithm and has strong applicability. The General Gauss Mixed Model can meet the peak diversity, bias, and multimodal properties of the error distribution, and the fitting effect is superior to the normal distribution, the Laplace distribution, and the t Location-Scale distribution model. The error model has a flexible shape, a concise expression, and high practical value for engineering.
Traditional high-voltage reactor monitoring and diagnosis research has problems such as high sampling demand, difficulty in noise reduction on site, many false alarms, and lack of on-site data. In order to solve the above problems, this paper proposes an acoustic–electric fusion high-voltage reactor acquisition system and defect diagnosis method based on reactor pulse current and ultrasonic detection signal. Using the envelope peak signal as the basic detection data, the sampling requirement of the system is reduced. To fill the missing data with partial discharge (PD) information, a method based on k-nearest neighbor (KNN) is proposed. An adaptive noise reduction method is carried out, and a noise threshold calculation method is given for the field sensors. A joint analysis method of acoustic and electrical signals based on correlation significance is established to determine whether a discharge event has occurred based on correlation significance. Finally, the method is applied to a UHV reactor on the spot, which proves the effectiveness of the method proposed in this paper.