Diogo Nogueira

Mr. Diogo Nogueira

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 September 2019 in Journal of Biological Engineering
Verified
Journal Article
Open access
PDF file
DNDiogo Nogueira
Diogo Nogueira
CRCarlos A.V. Rodrigues
Carlos A.V. Rodrigues
MCMarta Carvalho
Marta Carvalho
Cláudia MirandaCláudia Miranda
Cláudia Miranda
YHYas Hashimura
Yas Hashimura
Joaquim M.S. CabralJoaquim M.S. Cabral
Joaquim M.S. Cabral
Background: Since their inception, human induced pluripotent stem cells (hiPSCs) have held much promise for pharmacological applications and cell-based therapies. However, their potential can only be realised if large numbers of cells can be produced reproducibly on-demand. While bioreactors are ideal systems for this task, due to providing agitation and control of the culture parameters, the common impeller geometries were not designed for the expansion of mammalian cells, potentially leading to sub-optimal results. Results: This work reports for the first time the usage of the novel Vertical-Wheel single-use bioreactors for the expansion of hiPSCs as floating aggregates. Cultures were performed in the PBS MINI 0.1 bioreactor with 60 mL of working volume. Two different culture media were tested, mTeSR1 and mTeSR3D, in a repeated batch or fed-batch mode, respectively, as well as dextran sulfate (DS) supplementation. mTeSR3D was shown to sustain hiPSC expansion, although with lower maximum cell density than mTeSR1. Dextran sulfate supplementation led to an increase in 97 and 106% in maximum cell number when using mTeSR1 or mTeSR3D, respectively. For supplemented media, mTeSR1 + DS allowed for a higher cell density to be obtained with one less day of culture. A maximum cell density of (2.3 ± 0.2) × 106 cells∙mL− 1 and a volumetric productivity of (4.6 ± 0.3) × 105 cells∙mL− 1∙d− 1 were obtained after 5 days with mTeSR1 + DS, resulting in aggregates with an average diameter of 346 ± 11 μm. The generated hiPSCs were analysed by flow cytometry and qRT-PCR and their differentiation potential was assayed, revealing the maintenance of their pluripotency after expansion. Conclusions: The results here described present the Vertical-Wheel bioreactor as a promising technology for hiPSC bioprocessing. The specific characteristics of this bioreactor, namely in terms of the innovative agitation mechanism, can make it an important system in the development of hiPSC-derived products under current Good Manufacturing Practices.

17 May 2021 in Bioengineering
Verified
Journal Article
Open access
PDF file
DNDiogo Nogueira
Diogo Nogueira
Joaquim M.S. CabralJoaquim M.S. Cabral
Joaquim M.S. Cabral
CRCarlos A.V. Rodrigues
Carlos A.V. Rodrigues
Research on human stem cells, such as pluripotent stem cells and mesenchymal stromal cells, has shown much promise in their use for regenerative medicine approaches. However, their use in patients requires large-scale expansion systems while maintaining the quality of the cells. Due to their characteristics, bioreactors have been regarded as ideal platforms to harbour stem cell biomanufacturing at a large scale. Specifically, single-use bioreactors have been recommended by regulatory agencies due to reducing the risk of product contamination, and many different systems have already been developed. This review describes single-use bioreactor platforms which have been used for human stem cell expansion and differentiation, along with their comparison with reusable systems in the development of a stem cell bioprocess for clinical applications.

13 July 2018 in Journal of Chemical Technology & Biotechnology
Verified
Journal Article
Closed access
PDF file
CRCarlos A.V. Rodrigues
Carlos A.V. Rodrigues
TSTeresa P. Silva
Teresa P. Silva
DNDiogo Nogueira
Diogo Nogueira
Tiago FernandesTiago Fernandes
Tiago Fernandes
YHYas Hashimura
Yas Hashimura
JCJoaquim M.S. Cabral
Joaquim M.S. Cabral

23 June 2021 in Biomaterials Science
Verified
Journal Article
Closed access
PDF file
Fábio GarrudoFábio Garrudo
Fábio Garrudo
DNDiogo Nogueira
Diogo Nogueira
CRCarlos A.V. Rodrigues
Carlos A.V. Rodrigues
FFFlávio A. Ferreira
Flávio A. Ferreira
PPPatrizia Paradiso
Patrizia Paradiso
FFFrederico Ferreira
Frederico Ferreira
Coaxial PCL-PANI/PGS fibers are biodegradable and electroconductive (0.063 ± 0.029 S cm−1) for 21 days in PBS. Electrical stimulation of cultured iNPCs (30 days) lead to a dominant excitatory (VGLUT1) neural profile over an inhibitory (GAD67) one.

31 December 2020
Verified
Book Chapter
Closed access
PDF file
DNDiogo Nogueira
Diogo Nogueira
CRCarlos A.V. Rodrigues
Carlos A.V. Rodrigues
YHYas Hashimura
Yas Hashimura
SJSunghoon Jung
Sunghoon Jung
BLBrian Lee
Brian Lee
JCJoaquim M. S. Cabral
Joaquim M. S. Cabral

12 August 2022 in Bioengineering
Verified
Journal Article
Open access
PDF file
PNPedro M. Miguel Neto
Pedro M. Miguel Neto
DNDiogo Nogueira
Diogo Nogueira
YHYas Hashimura
Yas Hashimura
SJSunghoon Jung
Sunghoon Jung
Bruno PedrasBruno Pedras
Bruno Pedras
CRCarlos A.V. Rodrigues
Carlos A.V. Rodrigues
In this work, the oxygen transport and hydrodynamic flow of the PBS Vertical-Wheel MINI™ 0.1 bioreactor were characterized using experimental data and computational fluid dynamics simulations. Data acquired from spectroscopy-based oxygenation measurements was compared with data obtained from 3D simulations with a rigid-lid approximation and LES-WALE turbulence modeling, using the open-source software OpenFOAM-8. The mass transfer coefficients were determined for a range of stirring speeds between 10 and 100 rpm and for working volumes between 60 and 100 mL. Additionally, boundary condition, mesh refinement, and temperature variation studies were performed. Lastly, cell size, energy dissipation rate, and shear stress fields were calculated to determine optimal hydrodynamic conditions for culture. The experimental results demonstrate that the kL can be predicted using Sh=1.68Re0.551Sc13G1.18, with a mean absolute error of 2.08%. Using the simulations and a correction factor of 0.473, the expression can be correlated to provide equally valid results. To directly obtain them from simulations, a partial slip boundary condition can be tuned, ensuring better near-surface velocity profiles or, alternatively, by deeply refining the mesh. Temperature variation studies support the use of this correlation for temperatures up to 37 °C by using a Schmidt exponent of 1/3. Finally, the flow was characterized as transitional with diverse mixing mechanisms that ensure homogeneity and suspension quality, and the results obtained are in agreement with previous studies that employed RANS models. Overall, this work provides new data regarding oxygen mass transfer and hydrodynamics in the Vertical-Wheel bioreactor, as well as new insights for air-water mass transfer modeling in systems with low interface deformation, and a computational model that can be used for further studies.