Objective . X-ray-based imaging modalities including mammography and computed tomography (CT) are widely used in cancer screening, diagnosis, staging, treatment planning, and therapy response monitoring. Over the past few decades, improvements to these modalities have resulted in substantially improved efficacy and efficiency, and substantially reduced radiation dose and cost. However, such improvements have evolved more slowly than would be ideal because lengthy preclinical and clinical evaluation is required. In many cases, new ideas cannot be evaluated due to the high cost of fabricating and testing prototypes. Wider availability of computer simulation tools could accelerate development of new imaging technologies. This paper introduces the development of a new open-access simulation environment for x-ray-based imaging. The main motivation of this work is to publicly distribute a fast but accurate ray-tracing x-ray and CT simulation tool along with realistic phantoms and 3D reconstruction capability, building on decades of developments in industry and academia. Approach . The x-ray-based Cancer Imaging Simulation Toolkit (XCIST) is developed in the context of cancer imaging, but can more broadly be applied. XCIST is physics-based, written in Python and C/C++, and currently consists of three major subsets: digital phantoms, the simulator itself (CatSim), and image reconstruction algorithms; planned future features include a fast dose-estimation tool and rigorous validation. To enable broad usage and to model and evaluate new technologies, XCIST is easily extendable by other researchers. To demonstrate XCIST’s ability to produce realistic images and to show the benefits of using XCIST for insight into the impact of separate physics effects on image quality, we present exemplary simulations by varying contributing factors such as noise and sampling. Main results . The capabilities and flexibility of XCIST are demonstrated, showing easy applicability to specific simulation problems. Geometric and x-ray attenuation accuracy are shown, as well as XCIST’s ability to model multiple scanner and protocol parameters, and to attribute fundamental image quality characteristics to specific parameters. Significance . This work represents an important first step toward the goal of creating an open-access platform for simulating existing and emerging x-ray-based imaging systems. While numerous simulation tools exist, we believe the combined XCIST toolset provides a unique advantage in terms of modeling capabilities versus ease of use and compute time. We publicly share this toolset to provide an environment for scientists to accelerate and improve the relevance of their research in x-ray and CT.
The anharmonic phonon behavior in zirconium hydrides and deuterides, including ϵ-ZrH2, γ-ZrH, and γ-ZrD, has been investigated from aspects of inelastic neutron scattering (INS) and lattice dynamics calculations within the framework of density functional theory (DFT). The harmonic model failed to reproduce the spectral features observed in the experimental data, indicating the existence of anharmonicity in those materials and the necessity of further explanations. Here, we present a detailed study on the anharmonicity in zirconium hydrides/deuterides by exploring the 2D potential energy surface of hydrogen/deuterium atoms and solving the corresponding 2D single-particle Schrödinger equation to obtain the eigenfrequencies, which are then convoluted with the instrument resolution. The convoluted INS spectra qualitatively describe the anharmonic peaks in the experimental INS spectra and demonstrate that the anharmonicity originates from the deviations of hydrogen potentials from quadratic behavior in certain directions; the effects are apparent for the higher-order excited vibrational states, but small for the ground and first excited states.
Objective . We sought to systematically evaluate CatSim’s ability to accurately simulate the spatial resolution produced by a typical 64-detector-row clinical CT scanner in the projection and image domains, over the range of clinically used x-ray techniques. Approach. Using a 64-detector-row clinical scanner, we scanned two phantoms designed to evaluate spatial resolution in the projection and image domains. These empirical scans were performed over the standard clinically used range of x-ray techniques (kV, and mA). We extracted projection data from the scanner, and we reconstructed images. For the CatSim simulations, we developed digital phantoms to represent the phantoms used in the empirical scans. We developed a new, realistic model for the x-ray source focal spot, and we empirically tuned a published model for the x-ray detector temporal response. We applied these phantoms and models to simulate scans equivalent to the empirical scans, and we reconstructed the simulated projections using the same methods used for the empirical scans. For the empirical and simulated scans, we qualitatively and quantitatively compared the projection-domain and image-domain point-spread functions (PSFs) as well as the image-domain modulation transfer functions. We reported four quantitative metrics and the percent error between the empirical and simulated results. Main Results. Qualitatively, the PSFs matched well in both the projection and image domains. Quantitatively, all four metrics generally agreed well, with most of the average errors substantially less than 5% for all x-ray techniques. Although the errors tended to increase with decreasing kV, we found that the CatSim simulations agreed with the empirical scans within limits required for the anticipated applications of CatSim. Significance. The new focal spot model and the new detector temporal response model are significant contributions to CatSim because they enabled achieving the desired level of agreement between empirical and simulated results. With these new models and this validation, CatSim users can be confident that the spatial resolution represented by simulations faithfully represents results that would be obtained by a real scanner, within reasonable, known limits. Furthermore, users of CatSim can vary parameters including but not limited to system geometry, focal spot size/shape and detector parameters, beyond the values available in physical scanners, and be confident in the results. Therefore, CatSim can be used to explore new hardware designs as well as new scanning and reconstruction methods, thus enabling acceleration of improved CT scan capabilities.