9 November 2016 in IEEE Transactions on Medical Imaging
X-ray detectors in clinical computed tomography (CT) usually operate in current-integrating mode. Their complicated signal statistics often lead to intractable likelihood functions for practical use in model-based image reconstruction (MBIR). It is therefore desirable to design simplified statistical models without losing the essential factors. Depending on whether the CT transmission data are logarithmically transformed, pre-log and post-log models are two major categories of choices in CT MBIR. Both being approximations, it remains an open question whether one model can notably improve image quality over the other on real scanners. In this study, we develop and compare several pre-log and post-log MBIR algorithms under a unified framework. Their reconstruction accuracy based on simulation and clinical datasets are evaluated. The results show that pre-log MBIR can achieve notably better quantitative accuracy than post-log MBIR in ultra-low-dose CT, although in less extreme cases, post-log MBIR with handcrafted pre-processing remains a competitive alternative. Pre-log MBIR could play a growing role in emerging ultra-low-dose CT applications.
9 December 2022 in Visual Computing for Industry, Biomedicine, and Art
This review paper aims to summarize cardiac CT blooming artifacts, how they present clinically and what their root causes and potential solutions are. A literature survey was performed covering any publications with a specific interest in calcium blooming and stent blooming in cardiac CT. The claims from literature are compared and interpreted, aiming at narrowing down the root causes and most promising solutions for blooming artifacts. More than 30 journal publications were identified with specific relevance to blooming artifacts. The main reported causes of blooming artifacts are the partial volume effect, motion artifacts and beam hardening. The proposed solutions are classified as high-resolution CT hardware, high-resolution CT reconstruction, subtraction techniques and post-processing techniques, with a special emphasis on deep learning (DL) techniques. The partial volume effect is the leading cause of blooming artifacts. The partial volume effect can be minimized by increasing the CT spatial resolution through higher-resolution CT hardware or advanced high-resolution CT reconstruction. In addition, DL techniques have shown great promise to correct for blooming artifacts. A combination of these techniques could avoid repeat scans for subtraction techniques.
28 September 2022 in Physics in Medicine & Biology
Objective . X-ray-based imaging modalities including mammography and computed tomography (CT) are widely used in cancer screening, diagnosis, staging, treatment planning, and therapy response monitoring. Over the past few decades, improvements to these modalities have resulted in substantially improved efficacy and efficiency, and substantially reduced radiation dose and cost. However, such improvements have evolved more slowly than would be ideal because lengthy preclinical and clinical evaluation is required. In many cases, new ideas cannot be evaluated due to the high cost of fabricating and testing prototypes. Wider availability of computer simulation tools could accelerate development of new imaging technologies. This paper introduces the development of a new open-access simulation environment for x-ray-based imaging. The main motivation of this work is to publicly distribute a fast but accurate ray-tracing x-ray and CT simulation tool along with realistic phantoms and 3D reconstruction capability, building on decades of developments in industry and academia. Approach . The x-ray-based Cancer Imaging Simulation Toolkit (XCIST) is developed in the context of cancer imaging, but can more broadly be applied. XCIST is physics-based, written in Python and C/C++, and currently consists of three major subsets: digital phantoms, the simulator itself (CatSim), and image reconstruction algorithms; planned future features include a fast dose-estimation tool and rigorous validation. To enable broad usage and to model and evaluate new technologies, XCIST is easily extendable by other researchers. To demonstrate XCIST’s ability to produce realistic images and to show the benefits of using XCIST for insight into the impact of separate physics effects on image quality, we present exemplary simulations by varying contributing factors such as noise and sampling. Main results . The capabilities and flexibility of XCIST are demonstrated, showing easy applicability to specific simulation problems. Geometric and x-ray attenuation accuracy are shown, as well as XCIST’s ability to model multiple scanner and protocol parameters, and to attribute fundamental image quality characteristics to specific parameters. Significance . This work represents an important first step toward the goal of creating an open-access platform for simulating existing and emerging x-ray-based imaging systems. While numerous simulation tools exist, we believe the combined XCIST toolset provides a unique advantage in terms of modeling capabilities versus ease of use and compute time. We publicly share this toolset to provide an environment for scientists to accelerate and improve the relevance of their research in x-ray and CT.
18 March 2015 in IEEE Transactions on Biomedical Engineering
Goal: In K-edge tomographic imaging with photon counting detectors, the energy window width of photon counting detectors significantly affects the signal-to-noise ratio (SNR) of measured intensity data and the contrast-to-noise ratio (CNR) of reconstructed images. In this paper, we present an optimization method to determine an optimal window width around a K-edge for optimal SNR and CNR. Methods: An objective function is designed to describe SNR of the projection data based on the Poisson distribution of detected X-ray photons. Then, a univariate optimization method is applied to obtain an X-ray energy window width. Results: Numerical simulations are performed to evaluate the proposed method, and the results show that the optimal energy window width obtained from the proposed method produces not only optimal SNR data in the projection domain but also optimal CNR values in the image domain. Conclusion: The proposed method in the projection domain can determine an optimal energy window width for X-ray photon counting imaging, and achieve optimality in both projection and image domains. Significance: Our study provides a practical way to determine the optimal energy window width of photon counting detectors, which helps improve contrast resolution for X-ray K-edge tomographic imaging.
4 July 2024 in IEEE Transactions on Medical Imaging
The presence of metal objects leads to corrupted CT projection measurements, resulting in metal artifacts in the reconstructed CT images. AI promises to offer improved solutions to estimate missing sinogram data for metal artifact reduction (MAR), as previously shown with convolutional neural networks (CNNs) and generative adversarial networks (GANs). Recently, denoising diffusion probabilistic models (DDPM) have shown great promise in image generation tasks, potentially outperforming GANs. In this study, a DDPM-based approach is proposed for inpainting of missing sinogram data for improved MAR. The proposed model is unconditionally trained, free from information on metal objects, which can potentially enhance its generalization capabilities across different types of metal implants compared to conditionally trained approaches. The performance of the proposed technique was evaluated and compared to the state-of-the-art normalized MAR (NMAR) approach as well as to CNN-based and GAN-based MAR approaches. The DDPM-based approach provided significantly higher SSIM and PSNR, as compared to NMAR (SSIM: p < 10 -26 ; PSNR: p < 10 -21 ), the CNN (SSIM: p < 10 -25 ; PSNR: p < 10 -9 ) and the GAN (SSIM: p < 10 -6 ; PSNR: p < 0.05) methods. The DDPM-MAR technique was further evaluated based on clinically relevant image quality metrics on clinical CT images with virtually introduced metal objects and metal artifacts, demonstrating superior quality relative to the other three models. In general, the AI-based techniques showed improved MAR performance compared to the non-AI-based NMAR approach. The proposed methodology shows promise in enhancing the effectiveness of MAR, and therefore improving the diagnostic accuracy of CT.
28 February 2017 in IEEE Transactions on Computational Imaging
Projection and backprojection operations are essential in a variety of image reconstruction and physical correction algorithms in computed tomography (CT). The distance-driven (DD) projection and backprojection are widely used for their favorable image quality properties, highly sequential memory access pattern and low arithmetic cost. However, a typical DD implementation has an inner loop that adjusts the calculation depending on the relative position between voxel and detector cell boundaries. The irregularity of the branch behavior makes it inefficient to be implemented on massively parallel computing devices, such as graphics processing units (GPUs). Such irregular branch behaviors can be eliminated by factorizing the DD operation as three branchless steps: integration, linear interpolation, and differentiation, all of which are highly amenable to massive vectorization. In this paper, we implement and evaluate a highly parallel branchless DD algorithm for three-dimensional cone beam CT. The algorithm utilizes the texture memory and hardware interpolation on GPUs to achieve fast computational speed. The developed branchless DD algorithm achieved 137-fold speedup for forward projection and 188-fold speedup for backprojection relative to a single-thread CPU implementation. Compared with a state-of-the-art 32-thread CPU implementation, the proposed branchless DD achieved eight-fold acceleration for forward projection and ten-fold acceleration for backprojection. The GPU-based branchless DD method was evaluated by iterative reconstruction algorithms with both simulation and real datasets. It obtained visually identical images as the CPU reference algorithm.