Sergey V. Sokolkov

Dr. Sergey V. Sokolkov

Senior Researcher
orcid

Research Focus & Metrics

Academic Career Length

42Years (1985-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 March 2020 in Sensors
Verified
Journal Article
Open access
PDF file
KBKhiena Brainina
Khiena Brainina
MBMaria Bukharinova
Maria Bukharinova
Natalia StozhkoNatalia Stozhko
Natalia Stozhko
SSSergey V. Sokolkov
Sergey V. Sokolkov
Aleksey TarasovAleksey Tarasov
Aleksey Tarasov
MVMarina B. Vidrevich
Marina B. Vidrevich
An original voltammetric sensor (Au-gr/CVE) based on a carbon veil (CV) and phytosynthesized gold nanoparticles (Au-gr) was developed for ascorbic acid (AA) determination. Extract from strawberry leaves was used as source of antioxidants (reducers) for Au-gr phytosynthesis. The sensor was characterized by scanning electron microscopy, energy-dispersive X-ray spectroscopy and electrochemical methods. Optimal parameters of AA determination were chosen. The sensor exhibits a linear response to AA in a wide concentration range (1 μM–5.75 mM) and a limit of detection of 0.05 μM. The developed sensor demonstrated a high intra-day repeatability of 1 μM AA response (RSD = 1.4%) and its stability during six weeks, selectivity of AA determination toward glucose, sucrose, fructose, citric, tartaric and malic acids. The proposed sensor based on Au-gr provides a higher sensitivity and a lower limit of AA detection in comparison with the sensor based on gold nanoparticles synthesized by the Turkevich method. The sensor was successfully applied for the determination of AA content in fruit juices without samples preparation. The recovery of 99%–111% and RSD no more than 6.8% confirm the good reproducibility of the juice analysis results. A good agreement with the potentiometric titration data was obtained. A correlation (r = 0.9867) between the results of AA determination obtained on the developed sensor and integral antioxidant activity of fruit juices was observed.

1 February 1985 in Journal of Molecular Structure
Verified
Journal Article
Closed access
AAA. Almenningen
A. Almenningen
JBJ. Brunvoll
J. Brunvoll
MPM.V. Popik
M.V. Popik
SSSergey V. Sokolkov
Sergey V. Sokolkov
LVL.V. Vilkov
L.V. Vilkov
SSS. Samdal
S. Samdal

28 August 2020 in Chemosensors
Verified
Journal Article
Open access
PDF file
Natalia StozhkoNatalia Stozhko
Natalia Stozhko
MBMaria Bukharinova
Maria Bukharinova
EKEkaterina I. Khamzina
Ekaterina I. Khamzina
Aleksey TarasovAleksey Tarasov
Aleksey Tarasov
SSSergey V. Sokolkov
Sergey V. Sokolkov
A film carbon veil-based electrode (FCVE) modified with non-ionic surfactant Triton X-100 (TrX100) has been developed for nitrite determination. A new simple and producible technique of hot lamination (heat sealing) has been used for the FCVE manufacturing. The paper presents the findings of investigating the FCVE and the TrX100/FCVE by using voltammetry, chronoamperometry, and scanning electron microscopy. Modification of the electrode with TrX100 improves the hydrophilic property of its surface, which results in a larger electrode active area and higher sensitivity. Optimal conditions for nitrite determination with the use of the TrX100/FCVE have been identified. The linear range (LR) and the limit of detection (LOD) are 0.1–100 μM and 0.01 μM, respectively. The relative standard deviation (RSD) does not exceed 2.3%. High selectivity of the sensor ensures its successful application for the analysis of real samples (sausage products and natural water). The obtained results accord well with the results of the standard spectrophotometric method.

20 August 2021 in Biosensors
Verified
Journal Article
Open access
PDF file
MBMaria Bukharinova
Maria Bukharinova
Natalia StozhkoNatalia Stozhko
Natalia Stozhko
ENElizaveta A. Novakovskaya
Elizaveta A. Novakovskaya
EKEkaterina I. Khamzina
Ekaterina I. Khamzina
Aleksey TarasovAleksey Tarasov
Aleksey Tarasov
SSSergey V. Sokolkov
Sergey V. Sokolkov
The paper describes the development of a carbon veil-based electrode (CVE) for determining uric acid (UA) in saliva. The electrode was manufactured by lamination technology, electrochemically activated and used as a highly sensitive voltammetric sensor (CVEact). Potentiostatic polarization of the electrode at 2.0 V in H2SO4 solution resulted in a higher number of oxygen and nitrogen-containing groups on the electrode surface; lower charge transfer resistance; a 1.5 times increase in the effective surface area and a decrease in the UA oxidation potential by over 0.4 V, compared with the non-activated CVE, which was confirmed by energy dispersive X-ray spectroscopy, electrochemical impedance spectroscopy, chronoamperometry and linear sweep voltammetry. The developed sensor is characterized by a low detection limit of 0.05 µM and a wide linear range (0.09–700 µM). The results suggest that the sensor has perspective applications for quick determination of UA in artificial and human saliva. RSD does not exceed 3.9%, and recovery is 96–105%. UA makes a significant contribution to the antioxidant activity (AOA) of saliva (≈60%). In addition to its high analytical characteristics, the important advantages of the proposed CVEact are the simple, scalable, and cost-effective manufacturing technology and the absence of additional complex and time-consuming modification operations.

24 February 2022 in Electrochemical Science Advances
Verified
Journal Article
Open access
SSSergey V. Sokolkov
Sergey V. Sokolkov
The number of publications on the electrochemical analysis of liquids increases year by year. The growth of publication activity is largely due to the development of new biosensors and the introduction of nanomaterials into the practice of electrochemical analysis. It is not the task of the author to review the entire array of publications, since the basic principles of electrochemical analysis in most publications remain practically unchanged. The purpose of this critical review is to find answers to two important questions for the development of electroanalysis. First, are all of the used electrochemical methods providing a measurement in the strict metrological sense of this term? That is, do they provide the necessary accuracy, validity, reliability, and reproducibility of the measurement results? Secondly, is electroanalytics capable of meeting the challenge of the information revolution by significantly increasing the information efficiency of each individual measurement? To answer these questions, we will identify the main sources of sensor signal noise by considering the electrochemical sensor as the primary decoder of “chemical information” into an analytical signal. Then we will evaluate the information efficiency of various measurement methods by using the approach of thermodynamics of information processes and considering a sensor as an open thermodynamic system.

1 January 1986 in Journal of Structural Chemistry
Verified
Journal Article
Closed access
PDF file
VNV. P. Novikov
V. P. Novikov
SSSergey V. Sokolkov
Sergey V. Sokolkov
AGA. V. Golubinskii
A. V. Golubinskii
LVL. V. Vilkov
L. V. Vilkov