Stephan Lau

Dr. Stephan Lau


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2023 in NeuroImage
Verified
Journal Article
Open access
JBJelena Bozek
Jelena Bozek
LGLudovica Griffanti
Ludovica Griffanti
SLStephan Lau
Stephan Lau
MJMark Jenkinson
Mark Jenkinson
Modelling population reference curves or normative modelling is increasingly used with the advent of large neuroimaging studies. In this paper we assess the performance of fitting methods from the perspective of clinical applications and investigate the influence of the sample size. Further, we evaluate linear and non-linear models for percentile curve estimation and highlight how the bias-variance trade-off manifests in typical neuroimaging data. We created plausible ground truth distributions of hippocampal volumes in the age range of 45 to 80 years, as an example application. Based on these distributions we repeatedly simulated samples for sizes between 50 and 50,000 data points, and for each simulated sample we fitted a range of normative models. We compared the fitted models and their variability across repetitions to the ground truth, with specific focus on the outer percentiles (1st, 5th, 10th) as these are the most clinically relevant. Our results quantify the expected decreasing trend in variance of the volume estimates with increasing sample size. However, bias in the volume estimates only decreases a modest amount, without much improvement at large sample sizes. The uncertainty of model performance is substantial for what would often be considered large samples in a neuroimaging context and rises dramatically at the ends of the age range, where fewer data points exist. Flexible models perform better across sample sizes, especially for non-linear ground truth. Surprisingly large samples of several thousand data points are needed to accurately capture outlying percentiles across the age range for applications in research and clinical settings. Performance evaluation methods should assess both bias and variance. Furthermore, caution is needed when attempting to go near the ends of the age range captured by the source data set and, as is a well known general principle, extrapolation beyond the age range should always be avoided. To help with such evaluations of normative models we have made our code available to guide researchers developing or utilising normative models.

20 May 2008 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
SLStephan Lau
Stephan Lau
RERoland Eichardt
Roland Eichardt
Luca Di RienzoLuca Di Rienzo
Luca Di Rienzo
JHJens Haueisen
Jens Haueisen
This paper addresses the question of optimal sensor placement for magnetocardiographic field imaging. New magnetic sensor technologies allow less restrictive sensor positioning in this application. We develop a constraint framework for sensor positioning and use tabu search (TS) and particle swarm optimization (PSO) for finding an optimal set of sensors, whereby a new PSO algorithm is designed to fit the needs of our constraint framework. Numerical simulations are carried out with a three compartment boundary element torso model and a multi-dipole heart model. We find an optimal value of about 20 to 30 vectorial sensors and both TS and PSO yield similar sensor distributions. The comparison to sensors on regular grids shows that optimization of vectorial magnetic sensor setups may significantly improve reconstruction quality and that the number of sensors can be reduced.

7 April 2016 in Frontiers in Neuroscience
Verified
Journal Article
Open access
PDF file
SLStephan Lau
Stephan Lau
DGDaniel Güllmar
Daniel Güllmar
LFLars Flemming
Lars Flemming
DGDavid B. Grayden
David B. Grayden
MCMark J. Cook
Mark J. Cook
JHJens Haueisen
Jens Haueisen
Magnetoencephalography (MEG) signals are influenced by skull defects. However, there is a lack of evidence of this influence during source reconstruction. Our objectives are to characterize errors in source reconstruction from MEG signals due to ignoring skull defects and to assess the ability of an exact finite element head model to eliminate such errors. A detailed finite element model of the head of a rabbit used in a physical experiment was constructed from magnetic resonance and co-registered computer tomography imaging that differentiated nine tissue types. Sources of the MEG measurements above intact skull and above skull defects respectively were reconstructed using a finite element model with the intact skull and one incorporating the skull defects. The forward simulation of the MEG signals reproduced the experimentally observed characteristic magnitude and topography changes due to skull defects. Sources reconstructed from measured MEG signals above intact skull matched the known physical locations and orientations. Ignoring skull defects in the head model during reconstruction displaced sources under a skull defect away from that defect. Sources next to a defect were reoriented. When skull defects, with their physical conductivity, were incorporated in the head model, the location and orientation errors were mostly eliminated. The conductivity of the skull defect material non-uniformly modulated the influence on MEG signals. We propose concrete guidelines for taking into account conducting skull defects during MEG coil placement and modeling. Exact finite element head models can improve localization of brain function, specifically after surgery.

1 August 2014 in Clinical Neurophysiology
Verified
Journal Article
Closed access
SLStephan Lau
Stephan Lau
LFL. Flemming
L. Flemming
JHJens Haueisen
Jens Haueisen

25 June 2015 in Journal of Medical and Biological Engineering
Verified
Journal Article
Closed access
PDF file
MGMatthias Goernig
Matthias Goernig
BHBenjamin Hoeffling
Benjamin Hoeffling
SLStephan Lau
Stephan Lau
HFHans Reiner Figulla
Hans Reiner Figulla
JHJens Haueisen
Jens Haueisen

24 May 2016 in Sensors
Verified
Journal Article
Open access
PDF file
SLStephan Lau
Stephan Lau
BPBojana Petkovic
Bojana Petkovic
JHJens Haueisen
Jens Haueisen
Magnetocardiography (MCG) non-invasively provides functional information about the heart. New room-temperature magnetic field sensors, specifically magnetoresistive and optically pumped magnetometers, have reached sensitivities in the ultra-low range of cardiac fields while allowing for free placement around the human torso. Our aim is to optimize positions and orientations of such magnetic sensors in a vest-like arrangement for robust reconstruction of the electric current distributions in the heart. We optimized a set of 32 sensors on the surface of a torso model with respect to a 13-dipole cardiac source model under noise-free conditions. The reconstruction robustness was estimated by the condition of the lead field matrix. Optimization improved the condition of the lead field matrix by approximately two orders of magnitude compared to a regular array at the front of the torso. Optimized setups exhibited distributions of sensors over the whole torso with denser sampling above the heart at the front and back of the torso. Sensors close to the heart were arranged predominantly tangential to the body surface. The optimized sensor setup could facilitate the definition of a standard for sensor placement in MCG and the development of a wearable MCG vest for clinical diagnostics.