Bojana Petkovic

Dr. Bojana Petkovic

Advanced Electromagnetics Group, TU Ilmenau, Ilmenau, Thuringia, Germany
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 May 2016 in Sensors
Verified
Journal Article
Open access
PDF file
SLStephan Lau
Stephan Lau
BPBojana Petkovic
Bojana Petkovic
JHJens Haueisen
Jens Haueisen
Magnetocardiography (MCG) non-invasively provides functional information about the heart. New room-temperature magnetic field sensors, specifically magnetoresistive and optically pumped magnetometers, have reached sensitivities in the ultra-low range of cardiac fields while allowing for free placement around the human torso. Our aim is to optimize positions and orientations of such magnetic sensors in a vest-like arrangement for robust reconstruction of the electric current distributions in the heart. We optimized a set of 32 sensors on the surface of a torso model with respect to a 13-dipole cardiac source model under noise-free conditions. The reconstruction robustness was estimated by the condition of the lead field matrix. Optimization improved the condition of the lead field matrix by approximately two orders of magnitude compared to a regular array at the front of the torso. Optimized setups exhibited distributions of sensors over the whole torso with denser sampling above the heart at the front and back of the torso. Sensors close to the heart were arranged predominantly tangential to the body surface. The optimized sensor setup could facilitate the definition of a standard for sensor placement in MCG and the development of a wearable MCG vest for clinical diagnostics.

23 March 2022 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
BPBojana Petkovic
Bojana Petkovic
MZMarek Ziolkowski
Marek Ziolkowski
HKHermann Kutschka
Hermann Kutschka
HTHannes Toepfer
Hannes Toepfer
JHJens Haueisen
Jens Haueisen
A low residual environmental magnetic field is required for the proper operation of most optically pumped magnetometers (OPMs). This is achieved using a combination of passive and active magnetic shielding. Passive magnetic shielding often uses multiple layers of highly permeable materials. A realistic two-layer magnetically shielded room (MSR) for biomagnetic measurements is numerically studied using the finite element method. A measured B-H characteristic of Mumetal is used, which is linearly extrapolated from the Rayleigh region (RR) into the low magnetic field range. This extension of the magnetization curve yields no significant differences compared to using a constant permeability value for the low magnetic field range. Furthermore, we model the MSR with only one shield and apply a simple analytical method of images (MOI). The MOI yields on average a 100-fold reduction in computation time. The relative difference of the magnetic flux density computed with MOI and finite element method (FEM) is smaller than < 1% at the center of a spherical region of interest (ROI) with a radius of 0.3 m desired from the point of magnetoencephalography (MEG) using OPMs. The achieved accuracy of the MOI makes it suitable for the optimization of active shielding coils.

1 December 2019 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
BPBojana Petkovic
Bojana Petkovic
EDE. M. Dolker
E. M. Dolker
RSR. Schmidt
R. Schmidt
HTHannes Toepfer
Hannes Toepfer
JHJens Haueisen
Jens Haueisen

27 October 2016 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
BPBojana Petkovic
Bojana Petkovic
KWKonstantin Weise
Konstantin Weise
JHJens Haueisen
Jens Haueisen
Determination of the 3-D eddy current distribution inside a translatory moving conductor under a permanent magnet can accurately be done by using finite-element method (FEM). However, FEM calculations are very expensive, as they require discretization of the whole conductor volume. In this paper, we propose a new technique, to be called boundary element source method (BESM), where only boundary layers are discretized. The BESM is a modification of the hybrid boundary element method (HBEM). In the BESM, the concentrated point sources placed at the centers of boundary elements for the HBEM are replaced by distributed charge density over the area of the boundary element. This is especially useful in the regions, where neighboring boundary meshes significantly affect one another and when calculation point of eddy current is very close or belong to the surface of a boundary element. The method can handle arbitrary geometries of the specimen as well as the defect and arbitrary orientation of the magnetization vector. The accuracy of the proposed method is verified by comparing the results with the solutions obtained from a finite-element model. The proposed BESM approach is shown to be simple, robust, and computationally accurate.

15 November 2017 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
EDE.-M. Dolker
E.-M. Dolker
RSR. Schmidt
R. Schmidt
KWKonstantin Weise
Konstantin Weise
BPBojana Petkovic
Bojana Petkovic
MZMarek Ziolkowski
Marek Ziolkowski
JHJens Haueisen
Jens Haueisen
Two different forward models for Lorentz force evaluation, the approximate forward solution (AFS) and the novel extended area approach (EAA), are evaluated using a goal function scan. A setup that contains a spherical permanent magnet and a specimen of stacked aluminum sheets with a cuboidal defect of size 12 mmx 2 mmx 2 mm at a depth of 2 mm is simulated by the finite-element method (FEM). Deviations between force perturbation of FEM and AFS or EAA are compared in terms of normalized root mean square errors (NRMSEs). The goal function scan yields minimal NRMSE for the correct depth with values of 6.1% for AFS and 1.7% for EAA, corresponding to the determined defect dimensions of 7 mmx 10 mmx 2 mm for AFS and 11 mmx 2 mmx 2 mm for EAA.

16 November 2017 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
MZMarek Ziolkowski
Marek Ziolkowski
RSReinhard Schmidt
Reinhard Schmidt
BPBojana Petkovic
Bojana Petkovic
SGStephan Gorges
Stephan Gorges
JOJan-Marc Otterbach
Jan-Marc Otterbach
HBHartmut Brauer
Hartmut Brauer
A new approach to determine the defect response signals from defects located in isotropic/anisotropic conducting objects of any size based on the surface charge simulation method is presented in the framework of Lorentz force eddy current testing. The results are verified by finite element method and validated by measurements. Normalized root mean square deviations are less than $5%$ with respect to measurements.