Arben Gjukaj

Dr. Arben Gjukaj


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2024 in HighTech and Innovation Journal
Verified
Journal Article
Open access
PDF file
AGArben Gjukaj
Arben Gjukaj
VRVezir Rexhepi
Vezir Rexhepi
RBRaimonda Bualoti
Raimonda Bualoti
MCMarialis Celo
Marialis Celo
IKIsak Kerolli
Isak Kerolli
Powering through Challenges: Analyzing the Energy Crisis in the Western Balkans during the Pandemic Context

1 August 2024 in Ecological Engineering & Environmental Technology
Verified
Journal Article
Open access
AGArben Gjukaj
Arben Gjukaj
IKIsak Kerolli
Isak Kerolli
Qamil KabashiQamil Kabashi
Qamil Kabashi
RBRaimonda Bualoti
Raimonda Bualoti
This paper focuses on the multifaceted exploration of energy transition strategies in Kosovo, with a particular emphasis on the potential for repurposing degraded lands for renewable energy generation. As a developing nation grappling with increasing electricity demand and environmental concerns,...

6 September 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
KGKjani Guri
Kjani Guri
GHGezim Hodolli
Gezim Hodolli
SKSehad Kadiri
Sehad Kadiri
AGArben Gjukaj
Arben Gjukaj
LKLabinot Kastrati
Labinot Kastrati
This study investigates the effect of seasonal conductor sag on electromagnetic field (EMF) exposure to near 400 kV double-bundle overhead transmission lines. The conductor sag study resulted in clearance values of 28.0 m for winter (−10 °C, sag ≈ 7.0 m) and 23.4 m for summer (+35 °C, sag ≈ 11.65 m). For both seasonal examples, the electric field strength and magnetic flux density were calculated at a pedestrian height of 1.5 m, and the image approach to account for ground effects. The winter setup resulted in maximum values of 1.35 kV/m (E) and 27.2 µT (B), while the summer configuration produced higher values of 1.96 kV/m and 38.5 µT, respectively. Autumn field measurements, representing intermediate seasonal circumstances, produced average values of 1.294 kV/m and 1.399 µT, with peaks of 8.39 kV/m and 6.85 µT for electric field and magnetic flux density, respectively. The electric field projections were nearly identical to measurements; however, the magnetic field predictions were significantly higher, most likely due to the model’s assumptions of balanced currents and ideal geometry. These findings suggest that seasonal conductor sag variation is a real and substantial factor in assessing EMF exposure, with the electric field being particularly sensitive to clearance changes. The findings emphasize the need to incorporate a large analysis into EMF compliance assessments, especially in cases where terrain relief between towers may further diminish clearance in mid-span regions.

1 June 2025 in Ecological Engineering & Environmental Technology
Verified
Journal Article
Open access
KKKadri Kadriu
Kadri Kadriu
GKGazmend Kabashi
Gazmend Kabashi
AGArben Gjukaj
Arben Gjukaj
Qamil KabashiQamil Kabashi
Qamil Kabashi
The integration of renewable energy sources (RES), particularly wind power, into national power systems introduces significant operational and technical challenges, especially in countries with limited system flexibility, such as Kosovo. This study examines the impact of wind power on Kosovo's...