Alfons Fischer

Prof. Dr. Alfons Fischer

Department Microstructure Physics and Alloy-Design, Max-Planck-Institute for Iron-Research GmbH (MPIE), Max-Planck-Straße 1, D-40237 Düsseldorf, Germany
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 September 2021 in Nature Communications
Verified
Journal Article
Open access
PDF file
Chang LiuChang Liu
Chang Liu
ZLZhiming Li
Zhiming Li
WLWenjun Lu
Wenjun Lu
YBYan Bao
Yan Bao
WXWenzhen Xia
Wenzhen Xia
DRDierk Raabe
Dierk Raabe
Wear-related energy and material loss cost over 2500 Billion Euro per year. Traditional wisdom suggests that high-strength materials reveal low wear rates, yet, their plastic deformation mechanisms also influence their wear performance. High strength and homogeneous deformation behavior, which allow accommodating plastic strain without cracking or localized brittle fracture, are crucial for developing wear-resistant metals. Here, we present an approach to achieve superior wear resistance via in-situ formation of a strong and deformable oxide nanocomposite surface during wear, by reaction of the metal surface with its oxidative environment, a principle that we refer to as ‘reactive wear protection’. We design a TiNbZr-Ag alloy that forms an amorphous-crystalline oxidic nanocomposite surface layer upon dry sliding. The strong (2.4 GPa yield strength) and deformable (homogeneous deformation to 20% strain) nanocomposite surface reduces the wear rate of the TiNbZr-Ag alloy by an order of magnitude. The reactive wear protection strategy offers a pathway for designing ultra-wear resistant alloys, where otherwise brittle oxides are turned to be strong and deformable for improving wear resistance.

13 November 2017 in Materials
Verified
Journal Article
Open access
PDF file
MJMarcus Jäger
Marcus Jäger
HJHerbert P. Jennissen
Herbert P. Jennissen
FDFlorian Dittrich
Florian Dittrich
AFAlfons Fischer
Alfons Fischer
HKHedda Luise Köhling
Hedda Luise Köhling
The surface design of titanium implants influences not only the local biological reactions but also affects at least the clinical result in orthopaedic application. During the last decades, strong efforts have been made to improve osteointegration and prevent bacterial adhesion to these surfaces. Following the rule of “smaller, faster, cheaper”, nanotechnology has encountered clinical application. It is evident that the hierarchical implant surface micro- and nanotopography orchestrate the biological cascades of early peri-implant endosseous healing or implant loosening. This review of the literature gives a brief overview of nanostructured titanium-base biomaterials designed to improve osteointegration and prevent from bacterial infection.

1 May 2012 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
AFAlfons Fischer
Alfons Fischer
SWSabine Weiss
Sabine Weiss
Markus A. A WimmerMarkus A. A Wimmer
Markus A. A Wimmer

5 October 2018
Verified
Book Chapter
Closed access
PDF file
AFAlfons Fischer
Alfons Fischer
WDWlodzimierz Dudzinski
Wlodzimierz Dudzinski
BGBirgit Gleising
Birgit Gleising
PSPriska Stemmer
Priska Stemmer

21 January 2020 in Advanced Science
Verified
Journal Article
Open access
PDF file
SBShanoob Balachandran
Shanoob Balachandran
ZZZita Zachariah
Zita Zachariah
AFAlfons Fischer
Alfons Fischer
DMDavid Mayweg
David Mayweg
MWMarkus A. Wimmer
Markus A. Wimmer
MHMichael Herbig
Michael Herbig
Millions worldwide suffer from arthritis of the hips, and total hip replacement is a clinically successful treatment for end‐stage arthritis patients. Typical hip implants incorporate a cobalt alloy (Co–Cr–Mo) femoral head fixed on a titanium alloy (Ti‐6Al‐4V) femoral stem via a Morse taper junction. However, fretting and corrosion at this junction can cause release of wear particles and metal ions from the metallic implant, leading to local and systemic toxicity in patients. This study is a multiscale structural‐chemical investigation, ranging from the micrometer down to the atomic scale, of the underlying mechanisms leading to metal ion release from such taper junctions. Correlative transmission electron microscopy and atom probe tomography reveals microstructural and compositional alterations in the subsurface of the titanium alloy subjected to in vitro gross‐slip fretting against the cobalt alloy. Even though the cobalt alloy is comparatively more wear‐resistant, changes in the titanium alloy promote tribocorrosion and subsequent degradation of the cobalt alloy. These observations regarding the concurrent occurrence of electrochemical and tribological phenomena are vital to further improve the design and performance of taper junctions in similar environments.

26 February 2010 in Journal of Thermal Spray Technology
Verified
Journal Article
Closed access
PDF file
MHMareike Hahn
Mareike Hahn
AFAlfons Fischer
Alfons Fischer