Purpose: PEMF stimulation results in a higher O2 muscle supply during exercise through increased O2 release and uptake. Given the importance of oxygen uptake in sport activity, especially in aerobic disciplines such as cycling, we sought to investigate the influence of PEMF on muscle activity when subjects cycled at an intensity between low and severe. Methods: Twenty semi-professional cyclists performed a constant-load exercise with randomized active (ON) or inactive (OFF) PEMF stimulation. Each subject started the recording session with 1 min of cycling without load (warm-up), followed by an instantaneous increase in power, as the individualized workload (constant-load physical effort). PEMF loops were applied on the vastus medialis and biceps femoris of the right leg. We recorded the electromyographic activity from each muscle and measured blood lactate prior the exercise and during the constant-load physical effort. Results: PEMF stimulation caused a significant increase in muscle activity in the warm-up condition when subjects cycled without load (p < 0.001). The blood lactate concentration was higher during PEMF stimulation (p < 0.001), a possible consequence of PEMF’s influence on glycolytic metabolism. Conclusion: PEMF stimulation augmented the activity and the metabolism of muscular fibers during the execution of physical exercise. PEMF stimulation could be used to raise the amplitude of muscular responses to physical activity, especially during low-intensity exercise.
Background: Physical activity is essential in the prevention and management of type 2 diabetes mellitus (T2D), yet adherence to recommended activity levels remains insufficient. Wearable electronic devices have emerged as tools to support physical activity through self-monitoring and enhanced user engagement. This review synthesizes current evidence on the effectiveness of wearable technologies in improving adherence to physical activity and promoting clinical and metabolic health in adults with T2D. Methods: The review was conducted using systematic search strategies in PubMed and Scopus. We included studies that involved the use of wearable devices to monitor physical activity for at least seven consecutive days. The reported outcomes were related to physical activity adherence or clinical–metabolic health. Thirty-two studies met the inclusion criteria and were analyzed in terms of study design, device type, intervention characteristics, and outcomes. Results: Wearable devices were used either for monitoring daily activity in free-living conditions or within structured, often supervised, interventions. Most studies reported increased physical activity, particularly in step count. Several studies showed improvements in blood pressure and lipid profile, while results for HbA1c and BMI were mixed. Structured interventions with behavioural support produced more consistent and clinically relevant outcomes than passive monitoring alone. Conclusions: Wearable technologies can support physical activity in adults with T2D, especially when integrated into structured behavioural programmes. From a clinical standpoint, they may serve as useful tools to enhance lifestyle adherence, particularly when combined with professional support. Their inclusion in care pathways could help personalize interventions and improve long-term self-management.
Optic flow is a perceptual cue processed for self-motion control. The aim of this study was to investigate whether postural control is modulated by the speed of radial optic flow stimuli. The experiments were performed on 20 healthy volunteers using stabilometry and surface electromyography (EMG). The subjects were instructed to fixate a central fixation point while radial optic flow stimuli were presented full field, in the foveal and in the peripheral visual field at different dots speed (8, 11, 14, 17 and 20°/s). Fixation in the dark was used as control stimulus. The EMG analysis showed that male and female subjects reacted to the stimuli with different muscle activity (main effects for gender, muscle and laterality: p < 0.001). The analysis of the center of pressure (COP) parameters showed that optic flow stimuli had a different effect on the left and right limbs of males and females (main effects of laterality: p < 0.015; interaction effects of gender and laterality: p < 0.016). The low speed of optic flow stimuli (8 and 11°/s) evoked non-uniform directions of oscillations especially in peripheral stimulation in all subjects, meaning that optic flow simulating slow self-motion stabilizes body sway.
Pulsed electromagnetic fields (PEMFs) are used as non-invasive tools to enhance microcirculation and tissue oxygenation, with a modulatory influence on the microvasculature. This study aimed to measure the acute effect of PEMF on muscle oxygenation and its influence on pulmonary oxygen kinetics during exercise. Eighteen male cyclists performed, on different days, a constant-load exercise in both active (ON) and inactive (OFF) PEMF stimulations while deoxyhemoglobin and pulmonary oxygen kinetics, total oxygenation index, and blood lactate were collected. PEMF enhanced muscle oxygenation, with higher values of deoxyhemoglobin both at the primary component and at the steady-state level. Moreover, PEMF accelerated deoxyhemoglobin on-transition kinetic, with a shorter time delay, time constant, and mean response time than the OFF condition. Lactate concentration was higher during stimulation. No differences were found for total oxygenation index and pulmonary oxygen kinetics. Local application of a precise PEMF stimulation can increase the rate of the muscle O2 extraction and utilization. These changes were not accompanied by faster oxygen kinetics, reduced oxygen slow component, or reduced blood lactate level. It seems that oxygen consumption is more influenced by exercise involving large muscle mass like cycling, whereas PEMF might only act at the local level.
Objectives: A pulsed electromagnetic field (PEMF) induces electric currents in biological tissue, enhancing muscle energy expenditure during heavy constant-load exercises. In this paper, we investigate the PEMF effect on muscular activation in male sedentary people. Methods: The surface electromyographic (EMG) activity of the right leg’s vastus medialis (RVM) and biceps femoris (RBF) muscles was recorded and analyzed. The root mean square values were normalized to the peak amplitude observed during maximal voluntary contraction. Measurements were taken at baseline (stationary seated position), during warm-up (unloaded cycling), and throughout 15 min of constant-load exercise performed at moderate intensity. Subjects performed two experimental conditions, when PEMF was turned ON versus OFF. Results: No significant difference was found during the baseline. The analysis during warm-up showed significant differences between conditions (ON vs. OFF) for both muscles (RVM p = 0.019; RBF p < 0.001). The analysis during constant-load exercise showed significant differences between conditions (ON vs. OFF) for RVM only (p = 0.002). Conclusions: This study provides evidence that PEMF stimulation acutely enhances muscle activation, primarily in the vastus medialis, with a comparatively smaller effect on the biceps femoris during moderate-intensity cycling in sedentary young men. The observed increase in EMG activity suggests that PEMF may facilitate neuromuscular excitability and muscle recruitment, potentially through mechanisms related to calcium signaling and enhanced muscle perfusion.
Microsaccades are small eye movements produced during attempted fixation. During locomotion, the eyes scan the environment; the gaze is not always directed to the focus of expansion of the optic flow field. We sought to investigate whether the microsaccadic activity was modulated by eye position during the view of radial optic flow stimuli, and if the presence or lack of a proprioceptive input signal may influence the microsaccade characteristics during self-motion perception. We recorded the oculomotor activity when subjects were either standing or sitting in front of a screen during the view of optic flow stimuli that simulated specific heading directions with different gaze positions. We recorded five trials of each stimulus. Results showed that microsaccade duration, peak velocity, and rate were significantly modulated by optic flow stimuli and trial sequence. We found that the microsaccade rate increased in each condition from trial 1 to trial 5. Microsaccade peak velocity and duration were significantly different across trials. The analysis of the microsaccade directions showed that the different combinations of optic flow and eye position evoked non-uniform directions of microsaccades in standing condition with mean vectors in the upper-left quadrant of the visual field, uncorrelated with optic flow directions and eye positions. In sitting conditions, all stimuli evoked uniform directions of microsaccades. Present results indicate that the proprioceptive signals when the subjects stand up creates a different input that could alter the eye-movement characteristics during heading perceptions.