Christian Burri

Christian Burri


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 June 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
CBChristian Burri
Christian Burri
AHAlessa Hutfilz
Alessa Hutfilz
LGLorenz Grimm
Lorenz Grimm
SSSimon Salzmann
Simon Salzmann
PAPatrik Arnold
Patrik Arnold
RBRalf Brinkmann
Ralf Brinkmann
Optical microsurgery of the retinal pigment epithelium (RPE) requires reliable real-time dosimetry to prevent unwanted overexposure of the neuroretina. The system used in this experiment implements optical coherence tomography (OCT) to detect the intentional elimination of RPE cells. We evaluated the performance of OCT dosimetry in terms of its ability to detect RPE cell damage caused by microsecond laser pulses of varying duration. Therefore, ex-vivo porcine RPE choroid sclera explants were embedded in an artificial eye and exposed to single laser pulses of 2–20 µs duration (wavelength: 532 nm, exposure area: 120 × 120 µm2, intensity modulation factor: 1.3). Simultaneously, time-resolved OCT M-scans were recorded (central wavelength: 870 nm, scan rate: 33 kHz). Post-irradiation, RPE cell damage was quantified using a calcein-AM viability assay and compared with an OCT-dosimetry algorithm. The results of our experiments show that the OCT-based analysis successfully predicts RPE cell damage. At its optimal operating point, the algorithm achieved a sensitivity of 89% and specificity of 94% for pulses of 6 µs duration and demonstrated the ability to precisely control radiant exposure of a wide range of pulse durations towards selective real-time laser microsurgery.

2 June 2023 in Life
Verified
Journal Article
Open access
PDF file
CBChristian Burri
Christian Burri
SSSimon Salzmann
Simon Salzmann
MAMylène Amstutz
Mylène Amstutz
LHLeonie Hoffmann
Leonie Hoffmann
BPBoris Považay
Boris Považay
MFMartin Frenz
Martin Frenz
Optical microsurgery confined to the retinal pigment epithelium (RPE) requires locally optimized laser parameters and reliable real-time feedback dosimetry (RFD) to prevent unwanted neuroretinal overexposure. This study aimed to compare pulses of different durations and application modes (single, ramp, burst). Moreover, optical coherence tomography (OCT)-based RFD was investigated in an ex vivo experiment, utilizing nine porcine eyes that were exposed to laser pulses of 8, 12, 16 and 20 µs duration (wavelength: 532 nm, exposure area: 90 × 90 µm2, radiant exposure: 247 to 1975 mJ/µm2). Simultaneously, time-resolved OCT M-scans were recorded (central wavelength: 870 nm, scan rate: 85 kHz) for RFD. Post irradiation, retinal changes were assessed with color fundus photography (CFP) and cross-sectional OCT B-scans. RPE cell damage was quantified via fluorescence-based cell viability assay and compared to the OCT dosimetry feedback. Our experiments indicate cumulative RPE damage for pulse bursts of 16 µs and 20 µs, whereas no cumulative effects were found for pulse durations of 8 µs and 12 µs applied in ramp mode. According to statistical analysis, OCT-RFD correctly detected RPE cell damage with 96% sensitivity and 97% specificity using pulses of 8 µs duration in ramp mode.

20 November 2023 in Biomedical Optics Express
Verified
Journal Article
Closed access
CBChristian Burri
Christian Burri
SSSimon Salzmann
Simon Salzmann
JWJasmin Wandel
Jasmin Wandel
LHLeonie Hoffmann
Leonie Hoffmann
BPBoris Považay
Boris Považay
MFMartin Frenz
Martin Frenz
Selective retinal pigment epithelium (RPE) photodisruption requires reliable real-time feedback dosimetry (RFD) to prevent unwanted overexposure. In this study, optical coherence tomography (OCT) based RFD was investigated in ex vivo porcine eyes exposed to laser pulses of 8 mu s duration (wavelength: 532 nm, exposure area: 90 x 90 mu m2, radiant exposure: 247 to 1975 mJ/mu m2). For RFD, fringe washouts in time-resolved OCT M-scans (central wavelength: 870 nm, scan rate: 85 kHz) were compared to an RPE cell viability assay. Statistical analysis revealed a moderate correlation between RPE lesion size and applied treatment energy, suggesting RFD adaptation to inter-and intraindividual RPE pigmentation and ocular transmission.

19 May 2020 in Ophthalmic Research
Verified
Journal Article
Open access
PDF file
LCLuca Cedro
Luca Cedro
PHPascal W. Hasler
Pascal W. Hasler
CMChristoph Meier
Christoph Meier
BPBoris Povazay
Boris Povazay
CBChristian Burri
Christian Burri
PMPeter Maloca
Peter Maloca
Purpose: To evaluate the feasibility and safety of a coaxial dual-wavelength optical coherence tomography (OCT) device (marked as Hydra-OCT). Methods: Healthy participants without ocular pathology underwent retinal imaging using the Hydra-OCT allowing for simultaneous measurement of retinal scanning of 840 and 1,072 nm wavelength. Before and after measurement, best-corrected visual acuity and patients’ comfort were assessed. Representative OCT images from both wavelengths were compared by 5 independent graders using a subjective grading scheme. Results: A total of 30 eyes of 30 participants (8 females and 22 males) with a mean age of 26.5 years (range from 19 to 55 years) were included. Dual-wavelength image acquisition was made possible in each subject. The participant’s effort and comfort assessment using the Hydra-OCT imaging revealed an equivalent value as compared to the commercially available OCT machine. No adverse events were reported, and visual acuity was not altered by the Hydra-OCT. Imaging between the systems was comparable. Conclusions: This study provides evidence for the feasibility and safety of a coaxial dual-wavelength OCT imaging method under real-life conditions. The novel Hydra-OCT imaging device may offer additional insights into the pathology of retinal and choroidal diseases.

9 May 2023 in Life
Verified
Journal Article
Open access
PDF file
SSSimon Salzmann
Simon Salzmann
PWPhilip Wakili
Philip Wakili
SASami Al-Nawaiseh
Sami Al-Nawaiseh
BPBoris Považay
Boris Považay
CMChristoph Meier
Christoph Meier
CBChristian Burri
Christian Burri
The prevalent cause of retinal detachment is a full-thickness retinal break and the ingress of fluid into the subretinal space. To prevent progression of the detachment, laser photocoagulation (LPC) lesions are placed around the break in clinical practice to seal the tissue. Unlike the usual application under indirect ophthalmoscopy, we developed a semi-automatic treatment planning software based on a sequence of optical coherence tomography (OCT) scans to perform navigated LPC treatment. The depth information allows demarcation of the border where the neurosensory retina is still attached to the retinal pigment epithelium (RPE), which is critical for prevention of detachment progression. To evaluate the method, artificially provoked retinal breaks were treated in seven ex-vivo porcine eyes. Treatment outcome was assessed by fundus photography and OCT imaging. The automatically applied lesions surrounding each detachment (4.4–39.6 mm2) could be identified as highly scattering coagulation regions in color fundus photography and OCT. Between the planned and applied pattern, a mean offset of 68 µm (SD ± 16.5 µm) and a mean lesion spacing error of 5 µm (SD ± 10 µm) was achieved. The results demonstrate the potential of navigated OCT-guided laser retinopexy to improve overall treatment accuracy, efficiency, and safety.

14 October 2023 in Optica Open
Verified
Preprint
Open access
PDF file
CBChristian Burri
Christian Burri
SSSimon Salzmann
Simon Salzmann
JWJasmin Wandel
Jasmin Wandel
LHLeonie Hoffmann
Leonie Hoffmann
BPBoris Považay
Boris Považay
MFMartin Frenz
Martin Frenz
Selective retinal pigment epithelium (RPE) photodisruption requires reliable real-time feedback dosimetry (RFD) to prevent unwanted overexposure. In this study, optical coherence tomography (OCT) based RFD was investigated in ex vivo porcine eyes exposed to laser pulses of 8 µs duration (wavelength: 532 nm, exposure area: 90×90 µm², radiant exposure: 247 to 1975 mJ/µm²). For RFD, fringe washouts in time-resolved OCT M-scans (central wavelength: 870 nm, scan rate: 85 kHz) were compared to an RPE cell viability assay. Statistical analysis revealed a moderate correlation between RPE lesion size and applied treatment energy, suggesting RFD adaptation to inter- and intraindividual RPE pigmentation and ocular transmission.