Purpose: Cell therapy is a promising treatment for retinal pigment epithelium (RPE)-associated eye diseases such as age-related macular degeneration. Herein, selective microsecond laser irradiation targeting RPE cells was used for minimally invasive, large-area RPE removal in preparation for delivery of retinal cell therapeutics. Methods: Ten rabbit eyes were exposed to laser pulses 8, 12, 16, and 20 µs in duration (wavelength, 532 nm; top-hat beam profile, 223 × 223 µm²). Post-irradiation retinal changes were assessed with fluorescein angiography (FA), indocyanine green angiography (ICGA), and optical coherence tomography (OCT). RPE viability was evaluated with an angiographic probit model. Following vitrectomy, a subretinal injection of balanced salt solution was performed over a lasered (maximum 13.6 mm2) and untreated control area. Bleb retinal detachment (bRD) morphology was then evaluated by intraoperative OCT. Results: Within 1 hour after irradiation, laser lesions showed FA and ICGA leakage. OCT revealed that large-area laser damage was limited to the RPE. The angiographic median effective dose irradiation thresholds (ED50) were 45 µJ (90 mJ/cm2) at 8 µs, 52 µJ (104 mJ/cm2) at 12 µs, 59 µJ (118 mJ/cm2) at 16 µs, and 71 µJ (142 mJ/cm2) at 20 µs. Subretinal injection over the lasered area resulted in a controlled, shallow bRD rise, whereas control blebs were convex in shape, with less predictable spread. Conclusions: Large-area, laser-based removal of host RPE without visible photoreceptor damage is possible and facilitates surgical retinal detachment. Translational Relevance: Selective microsecond laser-based, large-area RPE removal prior to retinal cell therapy may reduce iatrogenic trauma.
Optical microsurgery of the retinal pigment epithelium (RPE) requires reliable real-time dosimetry to prevent unwanted overexposure of the neuroretina. The system used in this experiment implements optical coherence tomography (OCT) to detect the intentional elimination of RPE cells. We evaluated the performance of OCT dosimetry in terms of its ability to detect RPE cell damage caused by microsecond laser pulses of varying duration. Therefore, ex-vivo porcine RPE choroid sclera explants were embedded in an artificial eye and exposed to single laser pulses of 2–20 µs duration (wavelength: 532 nm, exposure area: 120 × 120 µm2, intensity modulation factor: 1.3). Simultaneously, time-resolved OCT M-scans were recorded (central wavelength: 870 nm, scan rate: 33 kHz). Post-irradiation, RPE cell damage was quantified using a calcein-AM viability assay and compared with an OCT-dosimetry algorithm. The results of our experiments show that the OCT-based analysis successfully predicts RPE cell damage. At its optimal operating point, the algorithm achieved a sensitivity of 89% and specificity of 94% for pulses of 6 µs duration and demonstrated the ability to precisely control radiant exposure of a wide range of pulse durations towards selective real-time laser microsurgery.
Optical microsurgery confined to the retinal pigment epithelium (RPE) requires locally optimized laser parameters and reliable real-time feedback dosimetry (RFD) to prevent unwanted neuroretinal overexposure. This study aimed to compare pulses of different durations and application modes (single, ramp, burst). Moreover, optical coherence tomography (OCT)-based RFD was investigated in an ex vivo experiment, utilizing nine porcine eyes that were exposed to laser pulses of 8, 12, 16 and 20 µs duration (wavelength: 532 nm, exposure area: 90 × 90 µm2, radiant exposure: 247 to 1975 mJ/µm2). Simultaneously, time-resolved OCT M-scans were recorded (central wavelength: 870 nm, scan rate: 85 kHz) for RFD. Post irradiation, retinal changes were assessed with color fundus photography (CFP) and cross-sectional OCT B-scans. RPE cell damage was quantified via fluorescence-based cell viability assay and compared to the OCT dosimetry feedback. Our experiments indicate cumulative RPE damage for pulse bursts of 16 µs and 20 µs, whereas no cumulative effects were found for pulse durations of 8 µs and 12 µs applied in ramp mode. According to statistical analysis, OCT-RFD correctly detected RPE cell damage with 96% sensitivity and 97% specificity using pulses of 8 µs duration in ramp mode.
Selective retinal pigment epithelium (RPE) photodisruption requires reliable real-time feedback dosimetry (RFD) to prevent unwanted overexposure. In this study, optical coherence tomography (OCT) based RFD was investigated in ex vivo porcine eyes exposed to laser pulses of 8 mu s duration (wavelength: 532 nm, exposure area: 90 x 90 mu m2, radiant exposure: 247 to 1975 mJ/mu m2). For RFD, fringe washouts in time-resolved OCT M-scans (central wavelength: 870 nm, scan rate: 85 kHz) were compared to an RPE cell viability assay. Statistical analysis revealed a moderate correlation between RPE lesion size and applied treatment energy, suggesting RFD adaptation to inter-and intraindividual RPE pigmentation and ocular transmission.
The prevalent cause of retinal detachment is a full-thickness retinal break and the ingress of fluid into the subretinal space. To prevent progression of the detachment, laser photocoagulation (LPC) lesions are placed around the break in clinical practice to seal the tissue. Unlike the usual application under indirect ophthalmoscopy, we developed a semi-automatic treatment planning software based on a sequence of optical coherence tomography (OCT) scans to perform navigated LPC treatment. The depth information allows demarcation of the border where the neurosensory retina is still attached to the retinal pigment epithelium (RPE), which is critical for prevention of detachment progression. To evaluate the method, artificially provoked retinal breaks were treated in seven ex-vivo porcine eyes. Treatment outcome was assessed by fundus photography and OCT imaging. The automatically applied lesions surrounding each detachment (4.4–39.6 mm2) could be identified as highly scattering coagulation regions in color fundus photography and OCT. Between the planned and applied pattern, a mean offset of 68 µm (SD ± 16.5 µm) and a mean lesion spacing error of 5 µm (SD ± 10 µm) was achieved. The results demonstrate the potential of navigated OCT-guided laser retinopexy to improve overall treatment accuracy, efficiency, and safety.
In the treatment of various retinal pigment epithelium (RPE) related retinal diseases, selective retina therapy (SRT) is highly demanded, as SRT intends to selectively damage the RPE while sparing the neurosensory retina (NSR) and the choroid. A gentle method for removing diseased host RPE cells is still missing regarding RPE stem cell therapy. Cell therapeutics for age-related macular degeneration are often implanted regardless of host RPE status in the target zone, which may result in RPE multilayering. Here, we study a novel laser for selective large-area RPE removal without damaging the surrounding tissue prior to RPE implantation to promote subretinal integration. Therefore, pigmented rabbit eyes were exposed to laser pulses of 8 μs in duration (wavelength, 532 nm; top-hat beam profile, 223 × 223 μm2). Postirradiation retinal changes were assessed with color fundus photography, fluorescein angiography, indocyanine green angiography, and optical coherence tomography (OCT). Here we present the histological outcome of four animals after laser treatment. Following euthanization, the eyes of the animals were processed for histology, sectioned in 5 μm paraffin sections and stained with hematoxylin and eosin. Particular emphasis was given to an OCT vs light microscopy comparison. Our results reveal that RPE can be removed selectively using laser pulses of 8 µs duration in the green spectral range without damaging the NSR. Therefore, this regime proves to be applicable in the sense of SRT.