Kai Zoßeder

Dr. Kai Zoßeder


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 April 2020 in Geothermal Energy
Verified
Journal Article
Open access
PDF file
DBD. Bohnsack
D. Bohnsack
MPM. Potten
M. Potten
DPD. Pfrang
D. Pfrang
PWP. Wolpert
P. Wolpert
KZKai Zoßeder
Kai Zoßeder
For the successful realization and productivity prediction of new hydrothermal projects in the South German Molasse Basin, the hydraulic matrix properties of the Upper Jurassic Malm reservoir have to be determined as accurately as possible. To obtain specific information on the distribution of the petrophysical parameters (e.g., rock density, porosity, and permeability) 363 samples of rare drilling cores from the reservoir northeast of Munich (wells Moosburg SC4 and Dingolfing FB) were investigated using different experimental methods. Additionally, porosity was calculated by a downhole resistivity log of a nearby borehole close to Munich for comparison and the attempt of transferability of the data set to other locations within the Central Molasse Basin. Core data were divided into groups of different stratigraphic and petrographic units to cover the heterogeneity of the carbonate aquifer and provide data ranges to improve reservoir and prediction models. Data for effective porosity show a high variance from 0.3 to 19.2% throughout this heterogeneous aquifer. Permeability measured on core samples is scattered over several orders of magnitude (10−4–102 mD). Permeability models based on the porosity–permeability relationship were used to estimate permeability for the whole aquifer section and identify possible flow zones. A newly developed empirical model based on distinct lithofacies types allows a permeability estimation with a deviation < 10 mD. However, fractured, karstified, and vuggy zones occurring in this typically karstified, fractured, and porous reservoir cannot yet be taken into account by the model and result in an underestimation of permeability on reservoir scale. Overall, the dominant permeability trends can be mapped well using this model. For the regional transfer and the correlation of the results, a core-related porosity/permeability log for the reservoir was compiled for a well close to Munich showing similarities to the core investigations. The validation of the regional transferability of the parameter set to other locations in the Molasse Basin was carried out by correlation with the interpreted log data of a well near Munich.

2 June 2021 in Geothermal Energy
Verified
Journal Article
Open access
PDF file
DBDaniel Bohnsack
Daniel Bohnsack
MPMartin Potten
Martin Potten
SFSimon Freitag
Simon Freitag
FEFlorian Einsiedl
Florian Einsiedl
KZKai Zoßeder
Kai Zoßeder
In geothermal reservoir systems, changes in pore pressure due to production (depletion), injection or temperature changes result in a displacement of the effective stresses acting on the rock matrix of the aquifer. To compensate for these intrinsic stress changes, the rock matrix is subjected to poroelastic deformation through changes in rock and pore volume. This in turn may induce changes in the effective pore network and thus in the hydraulic properties of the aquifer. Therefore, for the conception of precise reservoir models and for long-term simulations, stress sensitivity of porosity and permeability is required for parametrization. Stress sensitivity was measured in hydrostatic compression tests on 14 samples of rock cores stemming from two boreholes of the Upper Jurassic Malm aquifer of the Bavarian Molasse Basin. To account for the heterogeneity of this carbonate sequence, typical rock and facies types representing the productive zones within the thermal reservoir were used. Prior to hydrostatic investigations, the hydraulic (effective porosity, permeability) and geomechanical (rock strength, dynamic, and static moduli) parameters as well as the microstructure (pore and pore throat size) of each rock sample were studied for thorough sample characterization. Subsequently, the samples were tested in a triaxial test setup with effective stresses of up to 28 MPa (hydrostatic) to simulate in-situ stress conditions for depths up to 2000 m. It was shown that stress sensitivity of the porosity was comparably low, resulting in a relative reduction of 0.7–2.1% at maximum effective stress. In contrast, relative permeability losses were observed in the range of 17.3–56.7% compared to the initial permeability at low effective stresses. Stress sensitivity coefficients for porosity and permeability were derived for characterization of each sample and the different rock types. For the stress sensitivity of porosity, a negative correlation with rock strength and a positive correlation with initial porosity was observed. The stress sensitivity of permeability is probably controlled by more complex processes than that of porosity, where the latter is mainly controlled by the compressibility of the pore space. It may depend more on the compaction of precedented flow paths and the geometry of pores and pore throats controlling the connectivity within the rock matrix. In general, limestone samples showed a higher stress sensitivity than dolomitic limestone or dolostones, because dolomitization of the rock matrix may lead to an increasing stiffness of the rock. Furthermore, the stress sensitivity is related to the history of burial diagenesis, during which changes in the pore network (dissolution, precipitation, and replacement of minerals and cements) as well as compaction and microcrack formation may occur. This study, in addition to improving the quality of input parameters for hydraulic–mechanical modeling, shows that hydraulic properties in flow zones largely characterized by less stiff, porous limestones can deteriorate significantly with increasing effective stress.

3 September 2021 in Geothermal Energy
Verified
Journal Article
Open access
PDF file
FSFelix Schölderle
Felix Schölderle
MLMartin Lipus
Martin Lipus
DPDaniela Pfrang
Daniela Pfrang
TRThomas Reinsch
Thomas Reinsch
SHSven Haberer
Sven Haberer
KZKai Zoßeder
Kai Zoßeder
Fiber optic sensing has gained importance for wellbore monitoring and reservoir characterization in geothermal fields as it allows continuous, spatially highly resolved measurements. Distributed acoustic sensing (DAS) and distributed temperature sensing (DTS) technologies, among others, enable monitoring of flow regimes and heat transport inside the wellbore to describe the dynamical behavior of the reservoir. The technically challenging installation of a permanent fiber optic monitoring system in a geothermal production well over the entire wellbore length was conducted for the first time at the geothermal site Schäftlarnstraße in Munich, Germany. One cable with two DAS fibers, two DTS fibers, and one fiber for a downhole fiber optic pressure/temperature gauge were clamped to ¾-in. sucker rods and installed to 3.7 km measured depth to collect data from the wellbore after drilling, during testing, and during operations. We present DTS profiles during 3 months of well shut-in and show the results of two cold water injection tests conducted to localize inflow zones in the reservoir and to test the performance of the fiber optic setup. A vertical displacement in temperature peaks of approximately 1.5 m was observed during the injection tests, presumably resulting from thermal contraction of the sucker rod–cable setup. This was verified by analyzing the strain information from the DAS records over 1 h of warm-back after cold water injection with the calculated theoretical thermal contraction of DTS of the same period. We further verified the flowmeter measurements with a gradient velocity analysis of DTS profiles during injection. Intake to the major inflow zone was estimated to 93.5% for the first injection test, respective 94.0% for the second, intake of flowmeter was calculated to 92.0% for the same zone. Those values are confirmed by analyzing DTS profiles during the warm-back period after the well was shut.

13 October 2020 in Water Resources Research
Verified
Journal Article
Open access
PDF file
MGManuel A. Gossler
Manuel A. Gossler
Peter BayerPeter Bayer
Peter Bayer
GRGabriel Rau
Gabriel Rau
FEFlorian Einsiedl
Florian Einsiedl
KZKai Zoßeder
Kai Zoßeder
Heat transport in natural porous media, such as aquifers or streambeds, is generally modeled assuming local thermal equilibrium (LTE) between the fluid and solid phases. Yet, the mathematical and hydrogeological conditions and implications of this simplification have not been fully established for natural porous media. To quantify the occurrence and effects of local thermal disequilibrium during heat transport, we systematically compared thermal breakthrough curves from a LTE with those calculated using a local thermal nonequilibrium (LTNE) model, explicitly allowing for different temperatures in the fluid and solid phases. For the LTNE model, we developed a new correlation for the heat transfer coefficient representative of the conditions in natural porous aquifers using six published experimental results. By conducting an extensive parameter study (>50,000 simulations), we show that LTNE effects do not occur for grain sizes smaller than 7 mm or for groundwater flow velocities that are slower than 1.6 m day−1. The limits of LTE are likely exceeded in gravel aquifers or in the vicinity of pumped bores. For such aquifers, the use of a LTE model can lead to an underestimation of the effective thermal dispersion by a factor of up to 30 or higher, while the advective thermal velocity remains unaffected for most conditions. Based on a regression analysis of the simulation results, we provide a criterion which can be used to determine if LTNE effects are expected for particular conditions.

24 August 2019 in Geothermal Energy
Verified
Journal Article
Open access
PDF file
FKFlorian Konrad
Florian Konrad
ASAlexandros Savvatis
Alexandros Savvatis
FWFlorian Wellmann
Florian Wellmann
KZKai Zoßeder
Kai Zoßeder
Fault zones in the Upper Jurassic aquifer of the North Alpine Foreland Basin are generally regions with possibly increased hydraulic properties. They are consequently often part of the geothermal exploration concepts in this area and a primary target for the drilling operation. Data from this aquifer, gathered in pump tests, however, show that only four out of 41 successful wells exhibit hydraulic proof for the presence of such a fault zone in terms of a bi-/linear flow regime. Besides technical effects, also the contrast in hydraulic properties itself, between fault zone and surrounding host rock, can prevent the detection of a fault zone in pump test data. This means a certain threshold has to be surpassed until its effects become clearly visible. A simplified realistic numerical model was constructed and calibrated with pressure data from an exploration site in the south of Munich. This model was then used to observe the presence of linear and bilinear flows in dependence on the Malm aquifers parameter space. Sampling the possible hydraulic property combinations with the help of an HPC (high-performance computing) cluster and automating the detection of the corresponding main flow type allowed to quantify the areas in parameter space where the fault zone-related flow regimes of interest are present. Through the investigation of more than 30,000 combinations between fault zone permeability, matrix permeability, fault zone storage, matrix storage and fault zone thickness, it was found that, in the parameter space of the Malm aquifer, a bilinear flow can be observed for the first time only if the matrix permeability is lower than 2.0 × 10−13 m2, and a linear flow for matrix permeability values below 6.0 × 10−14 m2. Additionally, it was shown that fault zones, which have better hydraulic properties than the surrounding matrix, can indeed be hidden in pumping tests due to the parameter setting.

22 April 2021 in Water
Verified
Journal Article
Open access
PDF file
FHFlorian Heine
Florian Heine
KZKai Zoßeder
Kai Zoßeder
FEFlorian Einsiedl
Florian Einsiedl
A comprehensive hydrogeological understanding of the deep Upper Jurassic carbonate aquifer, which represents an important geothermal reservoir in the South German Molasse Basin (SGMB), is crucial for improved and sustainable groundwater resource management. Water chemical data and environmental isotope analyses of δD, δ18O and 87Sr/86Sr were obtained from groundwater of 24 deep Upper Jurassic geothermal wells and coupled with a few analyses of noble gases (3He/4He, 40Ar/36Ar) and noble gas infiltration temperatures. Hierarchical cluster analysis revealed three major water types and allowed a hydrochemical zoning of the SGMB, while exploratory factor analyses identified the hydrogeological processes affecting the water chemical composition of the thermal water. Water types 1 and 2 are of Na-[Ca]-HCO3-Cl type, lowly mineralised and have been recharged under meteoric cold climate conditions. Both water types show 87Sr/86Sr signatures, stable water isotopes values and calculated apparent mean residence times, which suggest minor water-rock interaction within a hydraulically active flow system of the Northeastern and Southeastern Central Molasse Basin. This thermal groundwater have been most likely subglacially recharged in the south of the SGMB in close proximity to the Bavarian Alps with a delineated northwards flow direction. Highly mineralised groundwater of water type 3 (Na-Cl-HCO3 and Na-Cl) occurs in the Eastern Central Molasse Basin. In contrast to water types 1 and 2, this water type shows substantial water-rock interaction with terrestrial sediments and increasing 40Ar/36Ar ratios, which may also imply a hydraulic exchange with fossil formation waters of overlying Tertiary sediments.