Felix Schölderle

Mr. Felix Schölderle

Technical University of Munich, Munich, Bavaria, Germany
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 September 2021 in Geothermal Energy
Verified
Journal Article
Open access
PDF file
FSFelix Schölderle
Felix Schölderle
MLMartin Lipus
Martin Lipus
DPDaniela Pfrang
Daniela Pfrang
TRThomas Reinsch
Thomas Reinsch
SHSven Haberer
Sven Haberer
KZKai Zoßeder
Kai Zoßeder
Fiber optic sensing has gained importance for wellbore monitoring and reservoir characterization in geothermal fields as it allows continuous, spatially highly resolved measurements. Distributed acoustic sensing (DAS) and distributed temperature sensing (DTS) technologies, among others, enable monitoring of flow regimes and heat transport inside the wellbore to describe the dynamical behavior of the reservoir. The technically challenging installation of a permanent fiber optic monitoring system in a geothermal production well over the entire wellbore length was conducted for the first time at the geothermal site Schäftlarnstraße in Munich, Germany. One cable with two DAS fibers, two DTS fibers, and one fiber for a downhole fiber optic pressure/temperature gauge were clamped to ¾-in. sucker rods and installed to 3.7 km measured depth to collect data from the wellbore after drilling, during testing, and during operations. We present DTS profiles during 3 months of well shut-in and show the results of two cold water injection tests conducted to localize inflow zones in the reservoir and to test the performance of the fiber optic setup. A vertical displacement in temperature peaks of approximately 1.5 m was observed during the injection tests, presumably resulting from thermal contraction of the sucker rod–cable setup. This was verified by analyzing the strain information from the DAS records over 1 h of warm-back after cold water injection with the calculated theoretical thermal contraction of DTS of the same period. We further verified the flowmeter measurements with a gradient velocity analysis of DTS profiles during injection. Intake to the major inflow zone was estimated to 93.5% for the first injection test, respective 94.0% for the second, intake of flowmeter was calculated to 92.0% for the same zone. Those values are confirmed by analyzing DTS profiles during the warm-back period after the well was shut.


10 January 2023 in Advances in Geosciences
Verified
Journal Article
Open access
PDF file
FSFelix Schölderle
Felix Schölderle
DPDaniela Pfrang
Daniela Pfrang
KZKai Zosseder
Kai Zosseder
The localization and characterization of hydraulically active zones in a geothermal well is a major task in understanding the hydro geothermal reservoir. This is often done based on interpretations of spinner flow meter measurements that are performed at the end of the well test while injecting cold water. Once a production well is equipped with an electric submersible pump, data collection inside the reservoir and monitoring of the flow zones is usually barely possible. In a 3.7 km (MD) deep geothermal production well in Munich, Germany, it was successfully demonstrated in 2019 that a permanently installed optical fiber cable could close this measurement gap. We used this fiber-optic monitoring system to collect distributed temperature data once the well was set into production. We inversely modeled the inflow from the formation into the borehole from the production temperature data with an energy and mass balance model. The derived flow profile correlates with previous flow meter analysis and indicates that a karstified region at the very top of the reservoir is the driving factor for hydraulics and obtained production temperature. Qualitatively, the two profiles acquired by distributed temperature sensing (DTS) and flow meter are matchable, yet the production inflow profile by DTS logging is more differentiated compared to spinner flow meter logs interpretation during injection.

19 January 2022 in Solid Earth
Verified
Journal Article
Open access
PDF file
MLMartin Peter Lipus
Martin Peter Lipus
FSFelix Schölderle
Felix Schölderle
TRThomas Reinsch
Thomas Reinsch
CWChristopher Wollin
Christopher Wollin
CKCharlotte Krawczyk
Charlotte Krawczyk
KZKai Zosseder
Kai Zosseder
Fiber-optic distributed acoustic sensing (DAS) data find many applications in wellbore monitoring such as flow monitoring, formation evaluation and well integrity studies. For horizontal or highly deviated wells, wellbore fiber-optic installations can be conducted by mounting the sensing cable to a rigid structure (casing/tubing) which allows for a controlled landing of the cable. We analyze a cold-water injection phase in a geothermal well with a 3.6 km long fiber-optic installation mounted to a 3/4 in. sucker rod by using both DAS and distributed temperature sensing (DTS) data. During cold-water injection, we observe distinct vibrational events (shock waves) which originate in the reservoir interval and migrate up- and downwards. We use temperature differences from the DTS data to determine the theoretical thermal contraction and integrated DAS data to estimate the actual deformation of the rod construction. The results suggest that the rod experiences thermal stresses along the installation length – partly in the compressional and partly in the extensional regime. We find strong evidence that the observed vibrational events originate from the release of the thermal stresses when the friction of the rod against the borehole wall is overcome. Within this study, we show the influence of temperature changes on the acquisition of distributed acoustic/strain sensing data along a fiber-optic cable suspended along a rigid but freely hanging rod. We show that observed vibrational events do not necessarily originate from induced seismicity in the reservoir but instead can originate from stick–slip behavior of the rod construction that holds the measurement equipment.

31 August 2022 in Energies
Verified
Journal Article
Open access
PDF file
FSFelix Schölderle
Felix Schölderle
GGGregor Götzl
Gregor Götzl
FEFlorian Einsiedl
Florian Einsiedl
KZKai Zoßeder
Kai Zoßeder
Most temperature predictions for deep geothermal applications rely on correcting bottom-hole temperatures (BHTs) to undisturbed or static formation temperatures (SFTs). The data used for BHT correction are usually of low quality due to a lack of information and poor documentation, and the uncertainty of the corrected SFT is therefore unknown. It is supposed that the error within the input data exceeds the error due to the uncertainty of the different correction schemes. To verify this, we combined a global sensitivity study with Sobol indices of six easy-to-use conventional correction schemes of the BHT data set of the Bavarian Molasse Basin with an uncertainty study and developed a workflow that aims at presenting a valid error range of the corrected SFTs depending on the quality of their input data. The results give an indication of which of the investigated correction methods should be used depending on the input data, as well as show that the unknown error in the input parameters exceeds the error of the individual BHT correction methods as such. The developed a priori uncertainty-based BHT correction helps to provide a real estimate of the subsurface temperatures needed for geothermal prospecting and probabilistic risk assessment.

5 May 2025 in Geothermal Energy
Verified
Journal Article
Open access
PDF file
FSFelix Schölderle
Felix Schölderle
DPDaniela Pfrang
Daniela Pfrang
VEValerie Ernst
Valerie Ernst
TWTheis Winter
Theis Winter
KZKai Zosseder
Kai Zosseder
The North Alpine Foreland Basin in Bavaria is one of Europe’s most important deep reservoirs for hydrogeothermal energy utilization for district heating. Most of the plants are located in the Munich metropolitan region, where there are both favorable geological conditions and a high demand for heat due to the urban character. However, the region's potential is far from fully utilized and extensive geothermal development is thus planned in the city of Munich and the surrounding municipalities. Reliable productivity prognoses help to ensure that this development is sustainable and efficient. We use the dense and comprehensive drilling data set in the region to derive a productivity zonation using multivariate methods. To do this, we derive geophysical and hydraulic parameters from the existing borehole measurements and combine them with hydrochemical, historical and technical data to derive a set of 24 individual parameters. For this parameter set, we carry out a principal component analysis (PCA) and single linkage hierarchical cluster analysis (HCA). The PCA reduces the data set to six main factors, which explain 80% of the data set variability. Of those, the most important factors fa1, fa2, and fa3, which explain 53% of the data set variability, contain mainly geological (fa1), hydrochemical (fa2), and technical parameters (fa3). The HCA reveals four main clusters, with clusters 3 and 2 in the north, 1 in the center of the study area, and 4 in the south. The spatial location of these clusters fits very well with the zoning assumed in the previous assessment analysis ‘Masterplan Geothermal Energy‘. Cluster 2 behaves very similar to cluster 3, but is separated from it by a different hydrochemistry (fa2). In addition, two outliers were identified at two doublets in the north of the study area, which are distinguished from the main clusters in one case by differing hydrochemistry and in the other case by differing hydraulic and thermal conditions. Furthermore, a sub-cluster of cluster 4 is the only one that scatters across the entire study area. However, this can be explained by factors that do not directly influence the productivity of the boreholes concerned. Our results indicate that we can divide the reservoir from north to south into three productivity types A to C, where we derive different outflow temperatures and porosities from regression equations of depth trends. Graphical Abstract