Arndt Last

Dr. Arndt Last

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2020 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
ZQZhi Qiao
Zhi Qiao
XSXianbo Shi
Xianbo Shi
PKPeter Kenesei
Peter Kenesei
ALArndt Last
Arndt Last
LALahsen Assoufid
Lahsen Assoufid
ZIZahir Islam
Zahir Islam
We present an effective approach using a matched pair of polymer-based condenser–objective lenses to build a compact full-field x-ray microscope with a high spatial resolution. A unique condenser comprising arrays of high-aspect-ratio prisms with equilateral cross section is used for uniformly illuminating samples over a large field of view (FOV) from all angles, which match the acceptance of an objective made of interdigitated orthogonal rows of one-dimensional lenses. State-of-the-art Talbot grating interferometry used to characterize these lenses for the first time revealed excellent focusing properties and minimal wavefront distortions. Using a specific lens pair designed for 20 keV x rays, short-exposure times, and image registration with a cross-correlation technique, we circumvent vibrational instabilities to obtain distortion-free images with a uniform resolution of 240 nm (smallest resolvable line pair) over a large FOV, 80 × 80 µm2 in extent. The results were contrasted with those collected using commercial two-dimensional parabolic lenses with a smaller FOV. This approach implemented on a diffractometer would enable diffraction-contrast or dark-field microscopy for fast observations of “mesoscopic” phenomena in real space complementing reciprocal-space studies using diffraction on the same instrument.

22 January 2025 in Communications Physics
Verified
Journal Article
Open access
PDF file
DGDoğa Gürsoy
Doğa Gürsoy
KYKaan Alp Yay
Kaan Alp Yay
EKElliot Kisiel
Elliot Kisiel
MWMichael Wojcik
Michael Wojcik
DSDina Sheyfer
Dina Sheyfer
ZIZahir Islam
Zahir Islam
Dark-field X-ray microscopy is a lens-based technique that enables real-space imaging of heterogeneous micro- and meso-scale ordered materials. However, achieving accurate three-dimensional (3D) reconstruction often requires meticulous sample alignment or rastering, requiring complex rotational setups and extended acquisition times. To address these challenges, we introduce a structured illumination technique optimized for 3D imaging of ordered materials at sub-micrometer length scales. Our approach employs a coded aperture to spatially modulate the incident X-ray beam, enabling 3D structural reconstruction from images captured at various aperture positions. Unlike current 3D imaging approaches, which often rely on rotational or rastering methods, our technique uses scanning X-ray silhouettes of the coded aperture for depth resolution along the diffraction axis. This eliminates the need for sample rotation or rastering, resulting in a highly stable and efficient imaging modality. We validated the efficacy of this approach through experimental imaging of an isolated twin domain within a bulk single crystal of an iron pnictide using a dark-field X-ray microscope. This advancement aligns with the enhanced brightness upgrades of modern synchrotron radiation facilities, unlocking new possibilities for high-resolution imaging of ordered materials.

10 May 2016 in Optics Express
Verified
Journal Article
Open access
PDF file
FMFelix Marschall
Felix Marschall
ALArndt Last
Arndt Last
MSMarkus Simon
Markus Simon
HVHarald Vogt
Harald Vogt
JMJürgen Mohr
Jürgen Mohr
The aperture of refractive X-ray lenses is limited by absorption and geometry. We introduce a specific simulation method to develop an aperture-optimized lens design for hard X-ray full field microscopy. The aperture-optimized lens, referred to as Taille-lens, allows for high spatial resolution as well as homogeneous image quality. This is achieved by the individual adaptation of the apertures of hundreds of lens elements of an X-ray imaging lens to the respective microscopy setup. For full field microscopy, the simulations result in lenses with both a large entrance and exit aperture and lens elements with smaller apertures in the middle of the lens.

5 August 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
AOAlexander Opolka
Alexander Opolka
DMDominik Müller
Dominik Müller
CFChristian Fella
Christian Fella
ABAndreas Balles
Andreas Balles
JMJürgen Mohr
Jürgen Mohr
ALArndt Last
Arndt Last
X-ray full-field microscopy at laboratory sources for photon energies above 10 keV suffers from either long exposure times or low resolution. The photon flux is mainly limited by the objectives used, having a limited numerical aperture NA. We show that this can be overcome by making use of the cone-beam illumination of laboratory sources by imaging the same field of view (FoV) several times under slightly different angles using an array of X-ray lenses. Using this technique, the exposure time can be reduced drastically without any loss in terms of resolution. A proof-of-principle is given using an existing laboratory metal-jet source at the 9.25 keV Ga Kα-line and compared to a ray-tracing simulation of the setup.

1 April 2022 in Journal of Micro/Nanopatterning, Materials, and Metrology
Verified
Journal Article
Open access
PDF file
MRMichael Richter
Michael Richter
TBThomas Beckenbach
Thomas Beckenbach
HDHeiner Daerr
Heiner Daerr
SPSven Prevrhal
Sven Prevrhal
MBMartin Börner
Martin Börner
PMPascal Meyer
Pascal Meyer
Clinical diagnostic x-ray imaging is currently based on the principle of differences of x-ray attenuation between tissues. Whereas attenuation contrast is often insufficient to allow differentiation between tissues such as cancer lesions in soft tissue or pathologic changes in the lung, research points to phase-contrast, and dark-field x-ray imaging as an option to overcome this limitation, with clinical1 – 5 as well as industrial applicability.6 Currently, the most promising technology to do phase contrast and dark-field imaging is interferometry using a Talbot–Lau interferometer, which requires microstructured gratings.7,8

17 July 2024 in Optics Express
Verified
Journal Article
Closed access
EKElliot Kisiel
Elliot Kisiel
IPIshwor Poudyal
Ishwor Poudyal
PKPeter Kenesei
Peter Kenesei
MEMark Engbretson
Mark Engbretson
ALArndt Last
Arndt Last
ZIZahir Islam
Zahir Islam
Recent developments in X-ray science provide methods to probe deeply embedded mesoscale grain structures and spatially resolve them using dark field X-ray microscopy (DFXM). Extending this technique to investigate weak diffraction signals such as magnetic systems, quantum materials and thin films prove challenging due to available detection methods and incident X-ray flux at the sample. We present a direct detection method developed in conjunction with KAImaging which focuses on DFXM studies in the hard X-ray range of 10s of keV and above capable of approaching nanoscale resolution. Additionally, we compare this direct detection scheme with routinely used scintillator-based optical detection and achieve an order of magnitude improvement in exposure times allowing for imaging of weakly diffracting ordered systems.