Xiaoyu Shen

Ms. Xiaoyu Shen


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 October 2021 in Sensors
Verified
Journal Article
Open access
PDF file
XSXiaoyu Shen
Xiaoyu Shen
YTyuntian teng
yuntian teng
XHXingxing Hu
Xingxing Hu
Traditional fluxgate sensors used in geomagnetic field observations are large, costly, power-consuming and often limited in their use. Although the size of the micro-fluxgate sensors has been significantly reduced, their performance, including indicators such as accuracy and signal-to-noise, does not meet observational requirements. To address these problems, a new race-track type probe is designed based on a magnetic core made of a Co-based amorphous ribbon. The size of this single-component probe is only Φ10 mm × 30 mm. The signal processing circuit is also optimized. The whole size of the sensor integrated with probes and data acquisition module is Φ70 mm × 100 mm. Compared with traditional fluxgate and micro-fluxgate sensors, the designed sensor is compact and provides excellent performance equal to traditional fluxgate sensors with good linearity and RMS noise of less than 0.1 nT. From operational tests, the results are in good agreement with those from a standard fluxgate magnetometer. Being more suitable for modern dense deployment of geomagnetic observations, this small-size fluxgate sensor offers promising research applications at lower costs.

29 November 2021 in Sensors
Verified
Journal Article
Open access
PDF file
XHXingxing Hu
Xingxing Hu
XWXi-Zhen Wang
Xi-Zhen Wang
BCBo Chen
Bo Chen
CLCai-Hua Li
Cai-Hua Li
YTYi-Xiang Tang
Yi-Xiang Tang
YTYuntian Teng
Yuntian Teng
In earthquake monitoring, an important aspect of the operational effect of earthquake intensity rapid reporting and earthquake early warning networks depends on the density and performance of the deployed seismic sensors. To improve the resolution of seismic sensors as much as possible while keeping costs low, in this article the use of multiple low-cost and low-resolution digital MEMS accelerometers is proposed to increase the resolution through the correlation average method. In addition, a cost-effective MEMS seismic sensor is developed. With ARM and Linux embedded computer technology, this instrument can cyclically store the continuous collected data on a built-in large-capacity SD card for approximately 12 months. With its real-time seismic data processing algorithm, this instrument is able to automatically identify seismic events and calculate ground motion parameters. Moreover, the instrument is easy to install in a variety of ground or building conditions. The results show that the RMS noise of the instrument is reduced from 0.096 cm/s2 with a single MEMS accelerometer to 0.034 cm/s2 in a bandwidth of 0.1–20 Hz by using the correlation average method of eight low-cost MEMS accelerometers. The dynamic range reaches more than 90 dB, the amplitude–frequency response of its input and output within −3 dB is DC −80 Hz, and the linearity is better than 0.47%. In the records from our instrument, earthquakes with magnitudes between M2.2 and M5.1 and distances from the epicenter shorter than 200 km have a relatively high SNR, and are more visible than they were prior to the joint averaging.

10 March 2022 in Atmosphere
Verified
Journal Article
Open access
PDF file
ZHZhaoBo He
ZhaoBo He
XHXingxing Hu
Xingxing Hu
YTyuntian teng
yuntian teng
GLGaochuan Liu
Gaochuan Liu
XZXiuxia Zhang
Xiuxia Zhang
XSXiaoyu Shen
Xiaoyu Shen
In order to minimize interruptions to recording, geomagnetic observatories usually use a back-up instrument operating simultaneously with the primary instrument in order to obtain comparative observations. Based on the correction parameter calculation method established in the previous work, we focused on the effects of temperature and instrument drift on the comparative geomagnetic vector observations. The linear influence of temperature on the comparative data was shown to be variable. The relative temperature coefficient changed around the temperature inflection point and showed a V-type distribution in a scatter plot. This conclusion was verified in laboratory experiments. The long-term time drift between the comparative instruments exhibits a linear pattern, and the fitness of the correction model can be evaluated by the degree to which the residual distribution of the fitted straight line conforms to the normal distribution. However, the absolute value of the long-term time drift between variometers with the same type of probe is very small. Therefore, long-term time drift correction should be carried out with care. The associated analysis and conclusions have the potential to benefit data agreement correction of long-term comparative geomagnetic vector observations and comparative testing of the performance of vector instruments.

26 September 2024 in Sensors
Verified
Journal Article
Open access
PDF file
XSXiaoyu Shen
Xiaoyu Shen
YCYujia Cao
Yujia Cao
The electrical resistivity of subsurface rocks is one of the important sensitive parameters characterizing the internal physics of the Earth. Currently, research on subsurface electrical structures using geomagnetic sounding methods primarily focuses on two approaches: the first is based on observations from a few geomagnetic stations, which have low spatial resolution and cannot effectively describe the distribution of anomalies; the second is based on mobile geomagnetic observations, which have low temporal resolution and cannot promptly reflect anomalies. To address these issues, this study deployed a dense geomagnetic array for long-term observation in the southern segment of the Xiaojiang Fault Zone in the Yuxi area of southern Yunnan. This setup aims to promptly capture seismic magnetic anomalies, providing more data support and fundamental information for short-term earthquake prediction. Based on the long-term observation data from the dense array, the study of the subsurface electrical structure is carried out. The results indicate that during the observation period, which was seismically quiet, the regional subsurface electrical structure remained stable. A large-scale subsurface low-resistivity body was observed in the region, and the electrical structures at the two ends of the southern segment of the Xiaojiang Fault Zone were found to be completely different.