Xingxing Hu

Xingxing Hu


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 November 2021 in Sensors
Verified
Journal Article
Open access
PDF file
JLJianfu LIN
Jianfu LIN
XLXue-Yan Li
Xue-Yan Li
JWJun-Fang Wang
Jun-Fang Wang
LWLixin WANG
Lixin WANG
XHXingxing Hu
Xingxing Hu
JLJun-Xiang Liu
Jun-Xiang Liu
Suffering from structural deterioration and natural disasters, the resilience of civil structures in the face of extreme loadings inevitably drops, which may lead to catastrophic structural failure and presents great threats to public safety. Earthquake-induced extreme loading is one of the major reasons behind the structural failure of buildings. However, many buildings in earthquake-prone areas of China lack safety monitoring, and prevalent structural health monitoring systems are generally very expensive and complicated for extensive applications. To facilitate cost-effective building-safety monitoring, this study investigates a method using cost-effective MEMS accelerometers for buildings’ rapid after-earthquake assessment. First, a parameter analysis of a cost-effective MEMS sensor is conducted to confirm its suitability for building-safety monitoring. Second, different from the existing investigations that tend to use a simplified building model or small-scaled frame structure excited by strong motions in laboratories, this study selects an in-service public building located in a typical earthquake-prone area after an analysis of earthquake risk in China. The building is instrumented with the selected cost-effective MEMS accelerometers, characterized by a low noise level and the capability to capture low-frequency small-amplitude dynamic responses. Furthermore, a rapid after-earthquake assessment scheme is proposed, which systematically includes fast missing data reconstruction, displacement response estimation based on an acceleration response integral, and safety assessment based on the maximum displacement and maximum inter-story drift ratio. Finally, the proposed method is successfully applied to a building-safety assessment by using earthquake-induced building responses suffering from missing data. This study is conducive to the extensive engineering application of MEMS-based cost-effective building monitoring and rapid after-earthquake assessment.

1 September 2019 in Applied Geophysics
Verified
Journal Article
Closed access
PDF file
YCYin Cai
Yin Cai
MSMei-Ling Shyu
Mei-Ling Shyu
YTYue-Xuan Tu
Yue-Xuan Tu
YTYun-Tian Teng
Yun-Tian Teng
XHXingxing Hu
Xingxing Hu

2 October 2021 in Sensors
Verified
Journal Article
Open access
PDF file
XSXiaoyu Shen
Xiaoyu Shen
YTyuntian teng
yuntian teng
XHXingxing Hu
Xingxing Hu
Traditional fluxgate sensors used in geomagnetic field observations are large, costly, power-consuming and often limited in their use. Although the size of the micro-fluxgate sensors has been significantly reduced, their performance, including indicators such as accuracy and signal-to-noise, does not meet observational requirements. To address these problems, a new race-track type probe is designed based on a magnetic core made of a Co-based amorphous ribbon. The size of this single-component probe is only Φ10 mm × 30 mm. The signal processing circuit is also optimized. The whole size of the sensor integrated with probes and data acquisition module is Φ70 mm × 100 mm. Compared with traditional fluxgate and micro-fluxgate sensors, the designed sensor is compact and provides excellent performance equal to traditional fluxgate sensors with good linearity and RMS noise of less than 0.1 nT. From operational tests, the results are in good agreement with those from a standard fluxgate magnetometer. Being more suitable for modern dense deployment of geomagnetic observations, this small-size fluxgate sensor offers promising research applications at lower costs.

29 November 2021 in Sensors
Verified
Journal Article
Open access
PDF file
XHXingxing Hu
Xingxing Hu
XWXi-Zhen Wang
Xi-Zhen Wang
BCBo Chen
Bo Chen
CLCai-Hua Li
Cai-Hua Li
YTYi-Xiang Tang
Yi-Xiang Tang
YTYuntian Teng
Yuntian Teng
In earthquake monitoring, an important aspect of the operational effect of earthquake intensity rapid reporting and earthquake early warning networks depends on the density and performance of the deployed seismic sensors. To improve the resolution of seismic sensors as much as possible while keeping costs low, in this article the use of multiple low-cost and low-resolution digital MEMS accelerometers is proposed to increase the resolution through the correlation average method. In addition, a cost-effective MEMS seismic sensor is developed. With ARM and Linux embedded computer technology, this instrument can cyclically store the continuous collected data on a built-in large-capacity SD card for approximately 12 months. With its real-time seismic data processing algorithm, this instrument is able to automatically identify seismic events and calculate ground motion parameters. Moreover, the instrument is easy to install in a variety of ground or building conditions. The results show that the RMS noise of the instrument is reduced from 0.096 cm/s2 with a single MEMS accelerometer to 0.034 cm/s2 in a bandwidth of 0.1–20 Hz by using the correlation average method of eight low-cost MEMS accelerometers. The dynamic range reaches more than 90 dB, the amplitude–frequency response of its input and output within −3 dB is DC −80 Hz, and the linearity is better than 0.47%. In the records from our instrument, earthquakes with magnitudes between M2.2 and M5.1 and distances from the epicenter shorter than 200 km have a relatively high SNR, and are more visible than they were prior to the joint averaging.

11 February 2022 in Earth, Planets and Space
Verified
Journal Article
Open access
PDF file
ZHZhaobo He
Zhaobo He
XHXingxing Hu
Xingxing Hu
YTYuntian Teng
Yuntian Teng
XZXiuxia Zhang
Xiuxia Zhang
XSXiaoyu Shen
Xiaoyu Shen
Geomagnetism, similar to other areas of geophysics, is an observation-based science. Data agreement between comparative geomagnetic vector observations is one of the most important evaluation criteria for high-quality geomagnetic data. The main influencing factors affecting the agreement between comparative observational data are the attitude angle, scale factor, long-term time drift, and temperature. In this paper, we propose a method based on a genetic algorithm and linear regression to correct for these effects and use the distribution pattern of points in Bland–Altman plots with a 95% confidence interval length to qualitatively and quantitatively evaluate the agreement between the comparative observational data. In Bland–Altman plots with better agreement, that is, with the corrected data, more than 95% of the points are distributed within the 95% confidence interval and there is no obvious pattern in the distribution of the points. Meanwhile, the length of 95% confidence interval decreased significantly after the correction. The method presented here has positive effects on the vector instrumentation detection and would enhance the robustness of geomagnetic observatory by bringing the data quality of the backup variometer data in line with the primary variometer. Graphical Abstract

10 March 2022 in Atmosphere
Verified
Journal Article
Open access
PDF file
ZHZhaoBo He
ZhaoBo He
XHXingxing Hu
Xingxing Hu
YTyuntian teng
yuntian teng
GLGaochuan Liu
Gaochuan Liu
XZXiuxia Zhang
Xiuxia Zhang
XSXiaoyu Shen
Xiaoyu Shen
In order to minimize interruptions to recording, geomagnetic observatories usually use a back-up instrument operating simultaneously with the primary instrument in order to obtain comparative observations. Based on the correction parameter calculation method established in the previous work, we focused on the effects of temperature and instrument drift on the comparative geomagnetic vector observations. The linear influence of temperature on the comparative data was shown to be variable. The relative temperature coefficient changed around the temperature inflection point and showed a V-type distribution in a scatter plot. This conclusion was verified in laboratory experiments. The long-term time drift between the comparative instruments exhibits a linear pattern, and the fitness of the correction model can be evaluated by the degree to which the residual distribution of the fitted straight line conforms to the normal distribution. However, the absolute value of the long-term time drift between variometers with the same type of probe is very small. Therefore, long-term time drift correction should be carried out with care. The associated analysis and conclusions have the potential to benefit data agreement correction of long-term comparative geomagnetic vector observations and comparative testing of the performance of vector instruments.