Paul Borbas

Dr. Paul Borbas

Department of Orthopaedic Surgery, University of Zurich, Uniklinik Balgrist, 8006 Zurich, Switzerland
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2021 in JSES International
Verified
Journal Article
Open access
BHBettina Hochreiter
Bettina Hochreiter
AHAnita Hasler
Anita Hasler
JHJulian Hasler
Julian Hasler
PKPhilipp Kriechling
Philipp Kriechling
PBPaul Borbas
Paul Borbas
CGChristian Gerber
Christian Gerber
Functional internal rotation (fIR) of the shoulder is frequently limited after reverse shoulder arthroplasty (RTSA). The objective of this study was to study a cohort of satisfied patients after RTSA who had comparable active mobility except for fIR and to identify factors associated with selective loss of fIR. A retrospective cohort study was conducted to compare 2 patient groups with either poor (≤ 2 points in the Constant-Murley score [CS]) or excellent (≥8 points in CS) fIR after RTSA at a minimum follow-up of 2 years. Influencing factors (demographic, surgical or implant related, radiographic parameters) and clinical outcome were analyzed. Fifty-two patients with a mean age of 72.8 (±9.3) and a mean follow-up of 41 months were included in the IR≤2 group and 63 patients with a mean age of 72.1 (±8.0) and a mean follow-up of 59 months in the IR≥8 group. All patients had undergone RTSA with the same implant type and only 2 different glenosphere sizes (36 and 40) for comparable indications. A multivariate analysis identified the following significant risk factors for poor postoperative fIR: poor preoperative fIR (pts in CS: 3 [range: 2-6] vs. 6 [range: 4-8], P<.0001), smoking (17.3% vs. 6.5%, P = .004), male gender (59.6% vs. 31.7%, P = .002), less preoperative to postoperative distalization of the greater tuberosity (Δ 19.4 mm vs. 22.2 mm, P = .026), a thin humeral insert (≤3 mm: 23.1% vs. 54.8%, P = .039), and a high American Society of Anesthesiologists score (≤ III: 30.8% vs. 14.3%, P = .043). Subscapularis repair status and glenosphere size had no influence on fIR. Clinical outcome scores improved in both groups from preoperatively to last follow-up. The IR≥8 group had overall significantly better outcome scores compared to the IR≤2 group (Δ 9.3% SSV and Δ 9.5% relative CS, P < .0001). There was no difference in CS between the cohorts when the score for fIR was discarded. Independent risk factors for poor postoperative fIR after RTSA are poor preoperative fIR, smoking, male gender, less preoperative to postoperative distalization of the greater tuberosity, a thin humeral insert height, and a high American Society of Anesthesiologists score. Except for male gender, these factors are modifiable. These findings may be a valuable addition to patient counselling as well as preoperative planning and preoperative and intraoperative decision-making. The relevance of fIR for overall satisfaction is substantiated by this study.

1 June 2022 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Open access
PKPhilipp Kriechling
Philipp Kriechling
SHSandro Hodel
Sandro Hodel
APAlexander Paszicsnyek
Alexander Paszicsnyek
ISInes Schwihla
Ines Schwihla
PBPaul Borbas
Paul Borbas
KWKarl Wieser
Karl Wieser
Acromial and scapular spine fractures (ASFs) are known complications following implantation of reverse total shoulder arthroplasty (RTSA). The entity of acromial stress reaction (ASR) without fracture has recently been described. The purpose of this study was to analyze the incidence, radiographic predictors, treatment options, healing rates, and clinical outcomes of ASF and ASR compared with a control group. A total of 854 primary RTSAs were implanted between 2005 and 2018 in a single shoulder unit of a tertiary referral hospital and retrospectively reviewed for the incidence of ASF and ASR. ASR was defined as pain at the acromion or scapular spine after fracture exclusion on computed tomography scans. The ASF group was matched to a control group. Preoperative and postoperative radiographs were analyzed for radiographic predictors of ASF or ASR. The impact of ASF and ASR, operative vs. nonoperative treatment, and fracture union on clinical outcomes (Constant-Murley score [CS], Subjective Shoulder Value [SSV], and range of motion) with a minimum follow-up period of 2 years was analyzed. A total of 46 ASFs (5.4%) in 44 patients and 44 ASRs (5.2%) in 43 patients were detected at a mean of 16 ± 24 months and 20 ± 23 months postoperatively, respectively. Predictive radiographic factors were an increased critical shoulder angle and lateralization shoulder angle. The overall union rate was 55% (22 of 40) but was significantly higher following operative treatment (9 of 11, 82%) compared with nonoperative treatment (13 of 29, 45%). Patients with ASF or ASR demonstrated inferior clinical outcomes (CS, 44 ± 21 and 48 ± 18; SSV, 52% ± 25% and 57% ± 27%) compared with the control group (CS, 66 ± 14; SSV, 82% ± 22%) independent of bony union or treatment at a mean of 59 ± 33 months (ASF) and 61 ± 38 months (ASR). ASF and ASR are frequent complications following RTSA implantation with similar poor clinical outcome measures. The healing rate was shown to be much higher with a surgical approach. Nevertheless, fracture consolidation does not result in better clinical outcomes compared with nonunion.

1 December 2012 in Journal of Shoulder and Elbow Surgery
Verified
Journal Article
Closed access
PBPaul Borbas
Paul Borbas
TKTanja Kraus
Tanja Kraus
HCHans Clement
Hans Clement
SGStefan Grechenig
Stefan Grechenig
AWAnnelie-Martina Weinberg
Annelie-Martina Weinberg
NHNima Heidari
Nima Heidari

15 June 2021 in Arthroscopy, Sports Medicine, and Rehabilitation
Verified
Journal Article
Open access
PBPaul Borbas
Paul Borbas
LFLukas Fischer
Lukas Fischer
LELukas Ernstbrunner
Lukas Ernstbrunner
AHArmando Hoch
Armando Hoch
EBElias Bachmann
Elias Bachmann
KWKarl Wieser
Karl Wieser
Purpose: To assess the mechanical properties, tendon resistance to suture cutout, and knot size of a broad variety of high‐strength sutures and tapes available for arthroscopic rotator cuff repair. Methods: Nine different types of high‐strength sutures and tapes for arthroscopic rotator cuff repair were studied: 6 were tapes (FiberTape, Hi‐Fi Tape, Permatape, SutureTape, UltraTape, and XBraid TT), and 3 were sutures (Dynacord, FiberWire, and Ultrabraid). First, mechanical tensile testing of suture loops (n = 6) was performed. Second, the suture material was passed through an intact human cadaveric rotator cuff tendon (supraspinatus or infraspinatus), and cyclic as well as load‐to‐failure testing was performed, 8 times for each suture or tape. Statistical analysis of groups (tapes vs sutures) and between each suture and each tape was performed. Results: Material testing revealed significant differences with superior mechanical properties of tapes compared with sutures regarding load for 3 mm of displacement (201 N vs 84 N, P < .0001), displacement at 200 N (3.6 mm vs 6.6 mm, P < .0001), stiffness (46 N/mm vs 25 N/mm, P < .0001), and ultimate load to failure (509 N vs 288 N, P < .0001). FiberTape showed the highest ultimate load to failure (805.5 ± 36.1 N), the highest load necessary for 3 mm of displacement (376.2 ± 19.1 N), and the lowest displacement at a 200‐N load (2 ± 0.1 mm). Permatape had the highest stiffness (58.5 ± 5.3 N/mm). FiberTape had the highest knot height (9.5 ± 1.3 mm) and knot width (3.8 ± 0.7 mm) of a suture loop with 7 square knots. The typical failure mode in the cadaveric study part was tendon cut through. Conclusions: Biomechanical in vitro testing showed that high‐strength suture tapes compared with regular high‐strength sutures have significantly better mechanical properties in both dry‐laboratory testing and human cadaveric rotator cuff tendon pullout testing. FiberTape outperformed the other tapes and the sutures used in this analysis. Nonetheless, differences in tendon testing appeared to be less substantial than in dry‐laboratory testing, and FiberTape had the highest knot height and width. Clinical Relevance: FiberTape revealed the most favorable biomechanical performance in dry‐laboratory and rotator cuff tendon testing. It may provide the best repair strength in vivo; however, it also has the largest knot size.

21 May 2021 in Journal of Hand Surgery (European Volume)
Verified
Journal Article
Closed access
PDF file
JGJohn G. Galbraith
John G. Galbraith
LHLachlan S. Huntington
Lachlan S. Huntington
PBPaul Borbas
Paul Borbas
DADavid Ackland
David Ackland
STStephen K. Tham
Stephen K. Tham
EEEugene Ek
Eugene Ek
We compared four methods of metacarpal shaft fixation: 2.2 mm intramedullary headless compression screw; 3.0 mm intramedullary headless compression screw; intramedullary K-wire fixation; and dorsal plate fixation. Transverse mid-diaphyseal fractures were created in 64 metacarpal sawbones and were assigned into four groups. Peak load to failure and stiffness were measured in cantilever bending and torsion. We found that dorsal plating had the highest peak load to failure. However, initial bending stiffness of the 3.0 mm intramedullary headless compression screw was higher than that of the dorsal plates. In torsion testing, dorsal plating had the highest peak torque, but there was no significant difference in torsional stiffness between the plate and intramedullary headless compression screw constructs. We concluded that intramedullary headless compression screw fixation is biomechanically superior to K-wires in cantilever bending and torsion; however, it is less stable than dorsal plating. In our study, the initial stability provided by K-wire fixation was sufficient to cope with expected loads in the early rehabilitation period, whereas dorsal plates and IHCS constructs provided stability far in excess of what is required.

11 April 2019 in Journal of Orthopaedic Surgery and Research
Verified
Journal Article
Open access
PDF file
PBPaul Borbas
Paul Borbas
CAChristoph A. Agten
Christoph A. Agten
ARAndrea B. Rosskopf
Andrea B. Rosskopf
AHAndreas Hingsammer
Andreas Hingsammer
KEKarim Eid
Karim Eid
LRLeonhard E. Ramseier
Leonhard E. Ramseier
It is not exactly known whether guided growth or definitive epiphysiodesis techniques are superior in treating limb length discrepancy (LLD). The purpose of the present study was therefore to find out if definitive epiphysiodesis is associated with more powerful LLD correction than tension band plate epiphysiodesis. Pediatric patients with LLD treated either with tension band plating as a guided growth technique (temporary epiphysiodesis) or a percutaneous drilling technique (definitive epiphysiodesis) around the knee and a minimum follow-up of 12 months were included in this retrospective study. Radiographic measurements were performed by two independent reviewers. The reduction in side difference between preoperative radiographs and last follow-up was calculated and compared between surgical techniques. Thirty-eight patients (mean age 13.6 years) were included, 17 treated with temporary and 21 with definitive epiphysiodesis. Average follow-up was at 578 days. The reduction of the LLD in 12 months was 5.7 mm in patients treated with temporary epiphysiodesis and 8.4 mm with definitive epiphysiodesis, respectively (p = 0.22). In both groups, LLD could be statistically significantly reduced after 12 and 24 months. Definitive epiphysiodesis had a lower revision rate (4.8% vs. 17.6%). Intra- and interobserver reliability of the measurements was excellent. As in earlier studies supposed, temporary epiphysiodesis with tension band plating seems to correct LLD less powerful compared to definitive percutaneous epiphysiodesis. However, in the present study, the differences of LLD correction were not statistically significant. We do not recommend the use of tension band plates for LLD correction due to inferior correction with higher complication and revision rate.