Gayan Abeynayake

Mr. Gayan Abeynayake

Cardiff University
orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 January 2021 in IEEE Transactions on Power Delivery
Verified
Journal Article
Open access
Gayan AbeynayakeGayan Abeynayake
Gayan Abeynayake
Gen LiGen Li
Gen Li
TJTibin Joseph
Tibin Joseph
JLJun LIANG
Jun LIANG
WMWenlong Ming
Wenlong Ming
DC technology has gained considerable interest in the medium voltage applications due to the benefits over the AC counterpart. However, to utilize the full capacity of this development, the selection of a suitable power electronic converter topology is a key aspect. From the pool of voltage source converters (VSC's), it is unclear which topology is suitable for multi-megawatt applications at medium voltage dc (MVdc) levels. To address this, the paper proposes a selection guideline based on reliability and optimum redundancy levels of VSCs for MVdc applications. This will be combined with other functional factors such as operational efficiency and return-on-investment. Three candidate multi-level topologies namely three-level neutral point clamped converter (3L-NPC), modular multi-level converter (MMC) and cascaded 3L-NPC (which is being used for the first MVdc link in the U.K.) have been evaluated over two-level-VSC from $\pm$ 10 kV to $\pm$ 50 kV. Results show that with the increase of MVdc voltage level MMC shows better performance whereas at low MVdc voltage levels 3L-NPC is the prominent topology.

27 April 2021 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Open access
Gayan AbeynayakeGayan Abeynayake
Gayan Abeynayake
TATom Van Acker
Tom Van Acker
DHDirk Van Hertem
Dirk Van Hertem
JLJun LIANG
Jun LIANG
With the increase of offshore wind farm size, the use of classical analytical reliability methods becomes computationally intractable. This paper proposes a holistic approach combining multi-state Markov processes and the universal generating function for the availability assessment of radial large-scale offshore wind farms. The proposed model combines multi-state wind turbine output, wind turbine reliability, and inter-array cable reliability models to assess the wind farm output at the point of common coupling. A strategy is developed to split the network into its feeders while still accounting for the wind turbine output dependence, significantly reducing the computational burden. Although the failure rates of inter-array cables are low, their inclusion is pertinent given high repair times and impact on wind farm output given the radial topology of the collection system. A case study on the Anholt wind farm indicates the necessity of accounting for the collection system, showing a significant reduction of 12 % in generation ratio availability for a generation ratio criterion of 95 %.

18 May 2021 in Energies
Verified
Journal Article
Open access
PDF file
RSRuijuan Sun
Ruijuan Sun
Gayan AbeynayakeGayan Abeynayake
Gayan Abeynayake
JLJun LIANG
Jun LIANG
KWKewen Wang
Kewen Wang
One key directive to realize the global transition towards net-zero emission goals is to integrate more renewable energy resources into the generation mix. Due to higher and more consistent wind speeds, offshore wind farms (OWFs) have the potential to generate more energy at a steadier rate than their onshore counterpart. However, at the collection system level, all the OWFs use alternating current (AC) technology at present. Nonetheless, with an increasing capacity of the single wind turbine (WT) and larger distances to the shore, the use of direct current (DC) technology at the collection system level is beneficial. To select a suitable DC collection system topology, this paper proposes a comprehensive analytical reliability evaluation method, based on the Universal Generating Function technique, together with associated economic factors. Four candidates DC collection system options were evaluated with different WT capacities for a 400 MW OWF. The availability indices such as Generation Ratio Availability and Expected Energy Not Supplied were used to assess their reliability levels. The results show that the radial topology with a single platform DC/DC converter is more reliable and economical than the other candidate options.

1 December 2019
Verified
Conference Paper
Closed access
Gayan AbeynayakeGayan Abeynayake
Gayan Abeynayake
GLGen Li
Gen Li
JLJun Liang
Jun Liang
Nicolaos CutululisNicolaos Cutululis
Nicolaos Cutululis
Recently, offshore renewable technologies have shown a rapid growth with the advancement in technology together with reduction of capital investment per unit size. This movement is further catalyzed by various government policy decisions and new set targets on renewable energy (RE) production. Due to higher wind speed, limited land availability and flexibility of transporting very large structures (with the increased size of a single wind turbine) offshore wind power plants provide commendable benefits over onshore wind plants. At present, only medium voltage ac is used in the offshore wind collection systems. However, the use of medium voltage direct current (MVdc) at the collection level is becoming more attractive due to advantages like lower systems losses, zero reactive power compensation and flexibility of power flow control compared to traditional ac collection systems. This paper intends to review opportunities and key challenges associated with the emerging MVdc technology for offshore wind collection systems. Attention is given to the DC wind turbine concept and selecting a suitable MVdc collection system topology with appropriate control modes.

3 October 2022 in Energies
Verified
Journal Article
Open access
PDF file
Gayan AbeynayakeGayan Abeynayake
Gayan Abeynayake
LCLiana Cipcigan
Liana Cipcigan
XDXiaolin Ding
Xiaolin Ding
The way of control and operation of an electrical power system has been changing rapidly with the integration of renewable energy sources (RES). One of the emerging issues that require addressing is the capability of RES to participate in the restoration process upon a total or partial system failure. However, with the continuous shutdown of large-centralised generators, which traditionally provided the black start support together with the variability of RES, the restoration process becomes much more complex. Primarily, the RES should have enough capacity to energise the load at the time of the restoration. Nonetheless, due to significant advantages, there is an increasing trend to use RES to meet the local energy demand by large industrial customers. The flexibility of shifting loads together with the surplus of RE generation could support the system operator during the system energisation process after a blackout. This paper mainly focuses on identifying the capabilities and factors that should be accounted for to participate in the system restoration process by large industrial consumers. The case study conducted on a large-scale steel factory in the UK reveals the possibility of supporting the restoration process under the bottom-up approach.