Jesus Iniesta

Dr. Jesus Iniesta

Department of Physical Chemistry, Institute of Electrochemistry, University of Alicante, Alicante, Spain

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2016 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
NHNaiara Hernández-Ibáñez
Naiara Hernández-Ibáñez
LGLeticia García-Cruz
Leticia García-Cruz
Vicente MontielVicente Montiel
Vicente Montiel
Christopher FosterChristopher Foster
Christopher Foster
Craig BanksCraig Banks
Craig Banks
JIJesus Iniesta
Jesus Iniesta

11 August 2020 in Sensors
Verified
Journal Article
Open access
PDF file
FJFrancisco Jiménez-Fiérrez
Francisco Jiménez-Fiérrez
MSMaria Isabel Gonzalez Sanchez
Maria Isabel Gonzalez Sanchez
RJRebeca Jiménez-Pérez
Rebeca Jiménez-Pérez
JIJesus Iniesta
Jesus Iniesta
EDELMIRA VALEROEDELMIRA VALERO
EDELMIRA VALERO
Herein, a novel electrochemical glucose biosensor based on glucose oxidase (GOx) immobilized on a surface containing platinum nanoparticles (PtNPs) electrodeposited on poly(Azure A) (PAA) previously electropolymerized on activated screen-printed carbon electrodes (GOx-PtNPs-PAA-aSPCEs) is reported. The resulting electrochemical biosensor was validated towards glucose oxidation in real samples and further electrochemical measurement associated with the generated H2O2. The electrochemical biosensor showed an excellent sensitivity (42.7 μA mM−1 cm−2), limit of detection (7.6 μM), linear range (20 μM–2.3 mM), and good selectivity towards glucose determination. Furthermore, and most importantly, the detection of glucose was performed at a low potential (0.2 V vs. Ag). The high performance of the electrochemical biosensor was explained through surface exploration using field emission SEM, XPS, and impedance measurements. The electrochemical biosensor was successfully applied to glucose quantification in several real samples (commercial juices and a plant cell culture medium), exhibiting a high accuracy when compared with a classical spectrophotometric method. This electrochemical biosensor can be easily prepared and opens up a good alternative in the development of new sensitive glucose sensors.

20 May 2013 in The Analyst
Verified
Journal Article
Closed access
PDF file
ABAriadna Brotons
Ariadna Brotons
LMLuis Alcaraz Mas
Luis Alcaraz Mas
JMJonathan P. Metters
Jonathan P. Metters
Craig BanksCraig Banks
Craig Banks
JIJesus Iniesta
Jesus Iniesta
Improvements in analytical methods for the determination and quantification of methylcytosine in DNA are vital since it has the potential to be used as a biomarker to detect different diseases in the first stage such as in the case of carcinomas and sterility. In this work we utilized screen printed graphite electrodes (SPGE) for studying the electrochemical response of all free DNA bases, methylcytosine and short oligonucleotides by cyclic voltammetry (CV) and square wave voltammetry (SWV). CV and SWV responses of free DNA bases and methylcytosine have been investigated by using SPGE platforms and the feasibility of detecting and quantifying cytosine and methylcytosine as free DNA moieties has been evaluated as a function of pH, concentration and the presence of the other free DNA bases in solution simultaneously. Repeatability of using SWV has been performed for the electrochemical behavior of both 250 μM cytosine and 250 μM methylcytosine in the presence of 25 μM guanine, with coefficient of variations of 6.9% and 2.6% respectively based upon peak current (N = 5). Six-mer oligonucleotides with a sequence 5′-XXXCGC-3′, where the XXX motif corresponds to TTT, TTA, TAA and AAA have been performed using SWV in 0.1 M acetate buffer pH 5.0 to explore how the DNA base position effects the electrooxidation of guanine and cytosine into the oligonucleotide. Furthermore SWV comparisons of the electrooxidation of the oligonucleotides 5′-CGCGCG-3′ and its methylated 5′-mCGmCGmCG-3′ have been performed with concentrations in acetate buffer solutions, and the interaction of both oligonucleotides with the graphitic surface of the SPGE has been demonstrated by fitting well-known adsorption models such as Freundlich and Langmuir kinetics according to the SWV current response of guanine, cytosine and methylcytosine into the oligonucleotide.

3 December 2015 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
ABAriadna Brotons
Ariadna Brotons
FVFrancisco J. Vidal-Iglesias
Francisco J. Vidal-Iglesias
José Solla GullónJosé Solla Gullón
José Solla Gullón
JIJesus Iniesta
Jesus Iniesta
The application of different carbon materials such as graphite, glassy carbon, boron-doped diamond, carbon nanofibers, carbon nanotubes and graphene for the electrooxidation of DNA-related molecules toward cytosine methylation electroanalytical monitoring is reviewed.

14 July 2015 in Electroanalysis
Verified
Journal Article
Closed access
PDF file
ABAriadna Brotons
Ariadna Brotons
ISIgnacio Sanjuan
Ignacio Sanjuan
Craig BanksCraig Banks
Craig Banks
FVFrancisco José Vidal‐Iglesias
Francisco José Vidal‐Iglesias
José Solla GullónJosé Solla Gullón
José Solla Gullón
JIJesus Iniesta
Jesus Iniesta

2 January 2014 in The Analyst
Verified
Journal Article
Open access
PDF file
MGMaria Gómez-Mingot
Maria Gómez-Mingot
Vicente MontielVicente Montiel
Vicente Montiel
Craig BanksCraig Banks
Craig Banks
JIJesus Iniesta
Jesus Iniesta
The direct electron transfer of cytochrome c has been studied at screen-printed graphite macroelectrodes without recourse to mediators or the need for any electrode pre-treatment as is commonly employed within the literature. A wide range of pH values from 2.0 to 11.0 have been explored upon the electrochemical response of cytochrome c and different voltammetric signatures have been observed. The direct electron transfer of the alkaline transition of cytochrome c was found impeded within alkaline media leading to either an irreversible redox process or even no voltammetric responses. In acidic aqueous media the electrochemical process is observed to undergo a mixed diffusion and adsorption controlled process rather than a purely diffusional process of the native conformation as observed at pH 7.0. Interestingly, at pH 3.5 a new conformational state is revealed in cooperation with the native conformation. The immobilization of the protein was satisfactorily obtained using a simple method by cycling the protein at specific solution pH values allowing amperometric responses to be obtained and gives rise to useful pseudo-peroxidase activity for sensing H2O2. Apparent Michaelis–Menten constant values (Km) were calculated via the Lineweaver–Burk method with deduced values of 25 ± 4, 98 ± 12 and 230 ± 30 mM, respectively for pH values of 2.0, 3.0 and 7.0. Such work is important for those utilising cytochrome c in bio-electrochemical and related applications.