Christopher Foster

Dr. Christopher Foster

Manchester Metropolitan University, Faculty of Science and Engineering, Manchester, United Kingdom
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 March 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
Christopher FosterChristopher Foster
Christopher Foster
MDMichael P. Down
Michael P. Down
YZYan Zhang
Yan Zhang
XJXiaobo Ji
Xiaobo Ji
SRSamuel J. Rowley-Neale
Samuel J. Rowley-Neale
Craig BanksCraig Banks
Craig Banks
3D printing technology provides a unique platform for rapid prototyping of numerous applications due to its ability to produce low cost 3D printed platforms. Herein, a graphene-based polylactic acid filament (graphene/PLA) has been 3D printed to fabricate a range of 3D disc electrode (3DE) configurations using a conventional RepRap fused deposition moulding (FDM) 3D printer, which requires no further modification/ex-situ curing step. To provide proof-of-concept, these 3D printed electrode architectures are characterised both electrochemically and physicochemically and are advantageously applied as freestanding anodes within Li-ion batteries and as solid-state supercapacitors. These freestanding anodes neglect the requirement for a current collector, thus offering a simplistic and cheaper alternative to traditional Li-ion based setups. Additionally, the ability of these devices’ to electrochemically produce hydrogen via the hydrogen evolution reaction (HER) as an alternative to currently utilised platinum based electrodes (with in electrolysers) is also performed. The 3DE demonstrates an unexpectedly high catalytic activity towards the HER (−0.46 V vs. SCE) upon the 1000th cycle, such potential is the closest observed to the desired value of platinum at (−0.25 V vs. SCE). We subsequently suggest that 3D printing of graphene-based conductive filaments allows for the simple fabrication of energy storage devices with bespoke and conceptual designs to be realised.

8 June 2018 in Biosensors
Verified
Journal Article
Open access
PDF file
Alejandro García-Miranda FerrariAlejandro García-Miranda Ferrari
Alejandro García-Miranda Ferrari
Christopher FosterChristopher Foster
Christopher Foster
PKPeter J. Kelly
Peter J. Kelly
Dale BrownsonDale Brownson
Dale Brownson
Craig BanksCraig Banks
Craig Banks
Screen-printed electrochemical sensing platforms, due to their scales of economy and high reproducibility, can provide a useful approach to translate laboratory-based electrochemistry into the field. An important factor when utilising screen-printed electrodes (SPEs) is the determination of their real electrochemical surface area, which allows for the benchmarking of these SPEs and is an important parameter in quality control. In this paper, we consider the use of cyclic voltammetry and chronocoulometry to allow for the determination of the real electrochemical area of screen-printed electrochemical sensing platforms, highlighting to experimentalists the various parameters that need to be diligently considered and controlled in order to obtain useful measurements of the real electroactive area.

19 September 2019 in Analytical Chemistry
Verified
Journal Article
Closed access
Eduardo Mathias RichterEduardo Mathias Richter
Eduardo Mathias Richter
DRDiego P. Rocha
Diego P. Rocha
RCRafael Melo Cardoso
Rafael Melo Cardoso
EKEdmund M. Keefe
Edmund M. Keefe
Christopher FosterChristopher Foster
Christopher Foster
Craig BanksCraig Banks
Craig Banks

30 August 2016 in Advanced Materials
Verified
Journal Article
Closed access
PDF file
YZYan Zhang
Yan Zhang
Christopher FosterChristopher Foster
Christopher Foster
Craig BanksCraig Banks
Craig Banks
LSLidong Shao
Lidong Shao
HHHongshuai Hou
Hongshuai Hou
XJXiaobo Ji
Xiaobo Ji

24 May 2017 in Advanced Functional Materials
Verified
Journal Article
Closed access
PDF file
YZYan Zhang
Yan Zhang
ZDZhiying Ding
Zhiying Ding
Christopher FosterChristopher Foster
Christopher Foster
CBCraig E. Banks
Craig E. Banks
XQXiaoqing Qiu
Xiaoqing Qiu
XJXiaobo Ji
Xiaobo Ji

9 March 2019 in Sensors
Verified
Journal Article
Open access
PDF file
Robert CrapnellRobert Crapnell
Robert Crapnell
AHAlex Hudson
Alex Hudson
Christopher FosterChristopher Foster
Christopher Foster
KEKasper Eersels
Kasper Eersels
BGBart Van Grinsven
Bart Van Grinsven
MPMarloes Peeters
Marloes Peeters
The accurate detection of biological materials has remained at the forefront of scientific research for decades. This includes the detection of molecules, proteins, and bacteria. Biomimetic sensors look to replicate the sensitive and selective mechanisms that are found in biological systems and incorporate these properties into functional sensing platforms. Molecularly imprinted polymers (MIPs) are synthetic receptors that can form high affinity binding sites complementary to the specific analyte of interest. They utilise the shape, size, and functionality to produce sensitive and selective recognition of target analytes. One route of synthesizing MIPs is through electropolymerization, utilising predominantly constant potential methods or cyclic voltammetry. This methodology allows for the formation of a polymer directly onto the surface of a transducer. The thickness, morphology, and topography of the films can be manipulated specifically for each template. Recently, numerous reviews have been published in the production and sensing applications of MIPs; however, there are few reports on the use of electrosynthesized MIPs (eMIPs). The number of publications and citations utilising eMIPs is increasing each year, with a review produced on the topic in 2012. This review will primarily focus on advancements from 2012 in the use of eMIPs in sensing platforms for the detection of biologically relevant materials, including the development of increased polymer layer dimensions for whole bacteria detection and the use of mixed monomer compositions to increase selectivity toward analytes.