Janusz Marchwiński

Dr. Janusz Marchwiński

Faculty of Architecture, University of Ecology and Management in Warsaw, Warsaw, Mazowieckie, Poland
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 September 2024 in Energies
Verified
Journal Article
Open access
PDF file
ASAgnieszka Starzyk
Agnieszka Starzyk
Kinga Rybak - NiedziolkaKinga Rybak - Niedziolka
Kinga Rybak - Niedziolka
Aleksandra NowyszAleksandra Nowysz
Aleksandra Nowysz
Janusz MarchwińskiJanusz Marchwiński
Janusz Marchwiński
AKAlicja Kozarzewska
Alicja Kozarzewska
Anna PodlasekAnna Podlasek
Anna Podlasek
A Carbon Footprint (CF) is defined as the total emissions of greenhouse gases, primarily carbon dioxide, methane, and nitrous oxide, and is a specific type of Environmental Footprint that measures human impact on the environment. Carbon dioxide emissions are a major contributor to anthropogenic greenhouse gases driving climate change. Wood, as a renewable and ecological material, has relatively low carbon emissions. The study aimed to review and analyze the criteria influencing the feasibility of constructing modern zero-carbon wooden buildings. The review was conducted in two phases: (i) a literature review and (ii) an assessment of existing buildings. The preliminary research led to (i) narrowing the focus to the years 2020–2024 and (ii) identifying key criteria for analysis: sustainable material sourcing, carbon sequestration, energy efficiency, life cycle assessment (LCA), and innovative construction practices. The study’s findings indicate that all these criteria play a vital role in the design and construction of new zero-carbon wooden buildings. They highlight the significant potential of wood as a renewable material in achieving zero-carbon buildings (ZCBs), positioning it as a compelling alternative to traditional construction materials. However, the research also underscores that despite wood’s numerous potential benefits, its implementation in ZCBs faces several challenges, including social, regulatory, and financial barriers.

1 January 2014 in Energy Procedia
Verified
Journal Article
Open access
Janusz MarchwińskiJanusz Marchwiński
Janusz Marchwiński
Switchable glazing technologies seem to be a promising component of solar buildings. Switchable glazing may controllably and invertably change its physical and visual properties by switching.Having been applied in buildings envelopes, the switchable glazing technologies are frequently regarded as an alternative measure for traditional solar protection elements like: blinds, louvres, overhangs etc. Yet, they are more integrated with buildings envelope creating kind of interactive barrier between external and internal environment. They also provide sleek and changeable glazed envelopes, thus becoming an important element of buildings architecture, too.The glass technologies to be considered in the paper are: SPD (suspended particle devices) LCD (liquid crystal devices), EC (electrochromic), GC (gasochromic) and micro-blinds technology.The paper concentrates on architectural evaluation of the application of the switchable glazing technologies as sun protection measures. They are examined in context of their influence on thermal and visual comfort first of all. Besides, aesthetical and energy –efficiency issues have been discussed.The paper is aimed at showing opportunities connected with application of the different switchable glazing technologies according to their impact on architecture.To this aim a comparative method has been used. The technologies were compared with each other on the following fields: thermal protection, lighting protection, visual contact, aesthetic variability, electricity consumption.It has been proved that the above mentioned technologies exert different impact on internal environment of the building and its architecture. They are relevant for different tasks- e.g. some of them are especially suitable for thermal protection, whereas the others should be used as visual control measure first of all. All of the technologies may be used both in hot and cold climates, but the way they should be used in the buildings envelope (e.g. place, solar orientation) are different

11 August 2023 in Energies
Verified
Journal Article
Open access
PDF file
Janusz MarchwińskiJanusz Marchwiński
Janusz Marchwiński
Vuk MiloševićVuk Milošević
Vuk Milošević
Anna StefańskaAnna Stefańska
Anna Stefańska
Elena LucchiElena Lucchi
Elena Lucchi
A dynamic development in building-integrated photovoltaics (BIPVs) has been observed in recent years. One of the manifestations of this trend is the integration of photovoltaic cells with tensile membrane structures, including canopies. Such solutions bring mutual benefits—the roofs provide a potentially large area for the application of photovoltaic cells while contributing to the improvement of the energy efficiency of the building. However, what is lacking is thorough research on the most favourable photovoltaic cell exposure within these roofs. This paper investigates the optimal position of photovoltaic cells in terms of energy gains related to exposure to solar radiation. Hypar geometries were simulated as the most characteristic of tensile membrane roofs and, simultaneously, the least obvious in the research context. Simulations were performed for 54 roof samples with the following geometric variables: roof height (1.0, 3.0 m) and membrane prestress (1:3, 1:1, 3:1). The research was conducted for three roof orientations defined by azimuth angles of 0, 22.5, and 45 degrees and three geographic locations, Oslo, Vienna, and Lisbon, representing Northern, Central, and Southern Europe, respectively. The Sofistik and Rhino + Ladybug software were used to create models and simulations. The study results show significant differences in the roof irradiation and, consequently, the optimal location of BIPVs depending on the above variables. Generally, it is the curvature that is the most important variable-less curved roofs are more irradiated and thus more suitable for BIPVs. Prestress and the azimuth angle are of lesser significance, but defining the optimal use of a BIPV depends on the adopted scenario regarding the percentage of membrane coverage with PVs—other recommendations concern the strategy of total or partial roof coverage with PV cells. The difference between optimally and incorrectly designed roofs may amount to a 50% electricity gain from PV cells.

3 August 2023 in Buildings
Verified
Journal Article
Open access
PDF file
ASAgnieszka Starzyk
Agnieszka Starzyk
MDMikołaj Donderewicz
Mikołaj Donderewicz
Kinga Rybak - NiedziolkaKinga Rybak - Niedziolka
Kinga Rybak - Niedziolka
Janusz MarchwińskiJanusz Marchwiński
Janusz Marchwiński
Magdalena Grochulska-SalakMagdalena Grochulska-Salak
Magdalena Grochulska-Salak
PVPolina Vietrova
Polina Vietrova
Contemporary problems related to the consequences of climate change and exposure to changing investment and implementation conditions are prompting the development of programmes adapting to climate change. Issues of adaptation and actions in relation to climate change are being discussed in the architectural, urban planning, and governmental communities. Models are being developed for shaping the functional and spatial structure, buildings and infrastructure in the city in relation to the projected climate change. Multi-criteria and interdisciplinary research is being carried out and solutions are being implemented for retaining water, minimising the heat island effect, reducing emissions and environmental impact by analysing the carbon footprint and introducing circular economy principles. The research is focused on the analysis of design and implementation conditions for multi-family housing projects in Poland, and the development of design guidelines enabling adaptation and mitigation of the negative effects of climate change, including heat island effects, smog, overheating, drought, and flooding in housing. Conclusions from the overview of the indicated documents and legal provisions for the implementation of sustainable development principles and adaptation to climate change in the investments under preparation (urban and architectural projects) enable the forecasting of development directions and ideological assumptions for shaping urbanised areas, providing the basis for shaping the resilience of the functional and spatial structure and the natural system in urban areas subject to transformation. Issues of implementing pro-environmental technologies and developing new urban planning standards disseminate the solutions of compact cities in which the development of multifunctional building complexes with public spaces equipped with greenery linked to the buildings are realised.

7 December 2024 in Energies
Verified
Journal Article
Open access
PDF file
Dušan RanđelovićDušan Ranđelović
Dušan Ranđelović
VJVladan S. Jovanović
Vladan S. Jovanović
MIMarko Ignjatović
Marko Ignjatović
Janusz MarchwińskiJanusz Marchwiński
Janusz Marchwiński
OKOłeksij Kopyłow
Ołeksij Kopyłow
Vuk MiloševićVuk Milošević
Vuk Milošević
This study demonstrates the benefits of comprehensive school building (SB) energy efficiency (EE) improvements through building envelope renovations, lighting upgrades, and changes to cleaner heat sources. The parametric study in the building energy simulation software was used to check the application of various interventions on the energy consumption of existing SBs while reducing CO2 emissions with the most profitable return on investment (ROI). The energy savings from window replacements did not correspond with expectations. However, other measures such as the wall, roof insulation, and lighting modernization improved EE by up to 152 kWh/m2 and 41 kg/m2 CO2/m2 annually. The study also points to a significant trade-off between district heating (which reduces CO2 but has a slower ROI) and other heating solutions. The results suggest that climate-specific insulation thickness and glazing type needs are required, and optimal insulation strategies are shown to improve EE by 48–56% and CO2 reductions of 45–56%. Lighting replacement and biogas boiler use were both impactful. The findings support the importance of sustainable practices, which should stimulate educational awareness and environmental responsibility. This research presents actionable insights for EE and sustainable development from within educational facilities.

22 December 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
Janusz MarchwińskiJanusz Marchwiński
Janusz Marchwiński
The idea of the article is to examine the perception of building-integrated photovoltaics (BIPV) by users of buildings in which BIPV has been applied. The study aims at determining the acceptance degree as well as problem areas related to the use of BIPV within façades in the aesthetic and utility context. The article includes survey research conducted among 232 employees working in six office and public buildings with BIPV in Poland. The buildings were selected so that the PV modules within their façades were visible both outside and inside the building. For this reason, two groups of buildings were chosen for the study: those with PV modules as external glazing and with an external PV shelves (three buildings each). The research results indicate differences in the perception of the aesthetic, semantic, and functional roles of BIPV depending on the aforementioned BIPV application method, the observation place (outside or inside the building), and employee characteristics, i.e., groups divided regarding such aspects as their age and time spent in the room with BIPV. The research novelty is in examining the influence of BIPV on users’ reactions in their workplace in terms of aesthetic and utility issues. The research includes post-occupancy evaluation method (POE), which is for the first time used in relation to BIPV in office and public utility buildings. The research can prove useful for investors and designers at the planning and design concept stage. The outcomes constitute a practical source of knowledge for BIPV manufacturers.