Silver and copper as additives of various biomaterials have been reported as the potential solutions for biomedicine applications, mostly because of inducing bactericidal effects. The application of those admixtures in diamond-like carbon (DLC) coatings may be desirable for orthopedic implants. In the present manuscript, the biological effect of coatings with up to about 7 at.% and 14 at.% of, respectively, Cu and Ag is compared. The morphology, chemical structure, and composition of films deposited on AISI 316LVM and Ti6Al7Nb is characterized. The live/dead analysis conducted with Escherichia coli shows a higher bactericidal potential of silver than copper. Although the Cu-doped coatings can positively affect the proliferation of Saos-2 and EA.hy926 cell lines, the results of XTT test are on the verge of 70% of viability. Biological effect of silver on EA.hy926 cell lines is negative but that admixture ensures high proliferation of osteoblasts in contact with coatings deposited on titanium alloy (over 20% better than for substrate material). In that case, the viability is reaching about 85% for Ag-doped coatings on AISI 316LVM and 75% on Ti6Al7Nb. The results indicate that for the sake of bactericidal coatings that may promote osteointegration, the candidates are DLC with silver content no higher than 10 at.%.
Background Complications after arthroplasty often result in irreversible disability. In some cases for the extremity to be salvaged, the permanent knee joint arthrodesis is the last-chance procedure. Modular implant design simplifies surgical technique but modularity may potentially compromise mechanical strength of an implant. Mechanical properties of the implant are particularly important in case of knee arthrodesis without bone-on-bone contact where forces during gait and weight bearing are transmitted directly through the nail. The aim of this article was to perform comparative analysis of the mechanical properties of modular nail CHARFIX2 FN, when compared to the femoral nail, used for knee arthrodesis; and to analyze the effectiveness of treatment with use of this nail based on the observations of clinical cases. Methods Comparative analysis of: the static 4-point bending test, dynamic 4-point bending test and static torsion test. All tests were performed in accordance with requirements of ASTM F 1264. A clinical analysis of 5 cases, in which CHARFIX2 FN nails were used, was also performed. Results Based on the results of mechanical tests, the strength characteristics of CHARFIX2 FN nail have been found superior and more advantageous than corresponding features of the standard femoral nail. For CHARFIX2 FN nail, the median for flexural stiffness was almost 4 times higher and for maximum torque value was almost 2 times higher when compared to the femoral nail. Observations of the clinical cases gave satisfactory results. Conclusions The obtained mechanical tests present significant differences between CHARFIX2 FN and the femoral nail in mechanical strength and, therefore, its improved stability and safety for patients during walking. It can be used for permanent knee immobilization with satisfactory clinical results. The functional outcomes and subjective measurements of pain in patients treated with CHARFIX2 FN group are satisfying.