Fibular hemimelia (FH) presents with foot and ankle deformity and leg length discrepancy. Many historic reconstructions have resulted in poor outcomes. This report reviews modern classification and reconstruction methods. The Paley SHORDT procedure (SHortening Osteotomy Realignment Distal Tibia) is designed to correct dynamic valgus deformity. The Paley SUPERankle procedure (Systematic Utilitarian Procedure for Extremity Reconstruction) is designed to correct fixed equino-valgus foot deformity. The leg length discrepancy in FH is successfully treated with serial lengthening and epiphysiodesis. Implantable intramedullary lengthening devices have led to all internal lengthenings. Recent advancements in techniques and implants in extramedullary implantable limb lengthening (EMILL) have allowed internal lengthenings in younger and smaller patients, who would traditionally require external fixation. These new internal techniques with lengthenings of up to 5 cm can be repeated more easily and frequently than external fixation, reducing the need to achieve larger single-stage lengthenings (e.g., 8 cm). Modern reconstruction methods with lengthening are able to achieve limb length equalization with a plantigrade-stable foot, resulting in excellent functional result comparable or better than a Syme’s amputation with prosthetic fitting.
Rotationplasty is a reconstructive option for severe congenital femoral deficiency (CFD). The senior author (D.P.) developed five new rotationplasty techniques for use in CFD based on the Paley classification, including the Paley–Brown (fusion femur to pelvis), Paley (fusion femur to femoral head), Paley–Winkelman (insertion tibial condyle to acetabulum), PaleySUPERhip–Van Nes (hip osteotomy with knee fusion) and PaleySling–Van Nes (hip reconstruction with knee fusion revision) rotationplasty techniques. The purpose of this study is to retrospectively evaluate the complications, radiographic outcomes and need for secondary surgery in 19 rotationplasty cases performed by the senior author (D.P.) for severe CFD from 2009 to 2019. Rotationplasty comprised only 2% of the authors treated CFD cases during this period. Average age at surgery was 8.6 years old. Average follow-up was 3.3 years. Sixteen concomitant procedures were performed including temporary arthrodesis, tibial osteotomy and SUPERhip procedure. The most common complication was wound necrosis/dehiscence, which occurred in 52% of the cases related to the circumferential incision and required a total of 31 additional debridements. Additional complications were successfully treated and included sciatic nerve palsy decompressed by abducting the femur, a tibial delayed union that underwent bone grafting, two distal femur failed epiphysiodesis treated by revision with one osteotomy and a thigh compartment syndrome requiring debridement. Indication specific rotationplasty successfully addresses the severe degree of femoral deficiency, deformity, and discrepancy in patients with CFD, despite high rates of wound complications.
Background: The mini C-arm is popular with hand surgeons, and they are particularly at risk for radiation exposure, as they cannot easily distance themselves from the radiation beam. We hypothesized that the nondominant hand receives more radiation exposure than the dominant hand as it is generally closer to the radiation source. This study seeks to determine whether a hand surgeon receives a different amount of radiation exposure to their hands based on hand dominance and then accounting for this, provide a more accurate assessment of hand radiation exposure from mini C-arm fluoroscopy. Methods: Two fellowship-trained hand surgeons wore ring dosimeters on both hands during surgeries with mini C-arm fluoroscopy involving bony work of the forearm and hand. Radiation exposure to the hands was measured from ring dosimeters. Results: Six-ring dosimeter pairs were worn during 64 cases, averaging 10.7 cases per ring. No ring met the minimal dose threshold of 30 mrem to record a numerical value. Each ring experienced an average of 413 seconds of fluoroscopy time and 66.3509 cGy*cm2 of radiation output from the mini C-arm. Conclusions: The results do not allow comparison of radiation exposure related to hand dominance. Assuming worst-case scenario: each ring measured 29 mrem (just below the threshold), the surgeon’s hands experienced 2.7 mrem per case. This would allow a hand surgeon to perform 18 391 cases per year before exceeding the allowable annual hand exposure limit of 50 000 mrem set by the National Council of Radiation Protection and Measurements and International Commission on Radiological Protection.
Purpose: Traditional lower limb deformity analysis in pediatrics and adults centers on the anatomical center of the knee. However, in high tibial osteotomy (HTO) for medial compartment knee osteoarthritis (KOA), the surgical goal is often valgus overcorrection toward a lateral weight-bearing point. This study quantified the effect of using a lateral weight-bearing point versus the center of the knee on lower-limb alignment parameters and assessed how these differences may influence surgical decision-making. Methods: A retrospective radiographic study was conducted in 20 patients with unicompartmental KOA who underwent HTO. Alignment was measured using 2 methods: the anatomical center of the knee and a 62.5% lateral weight-bearing point as the lateral weight-bearing reference point. Measured parameters included the mechanical lateral distal femoral angle (mLDFA), mechanical medial proximal tibial angle (mMPTA), mechanical lateral distal tibial angle (mLDTA), and mechanical hip-knee-ankle angle (mHKAA). Methods were compared using paired t tests. Results: Using a 62.5% lateral weight-bearing point altered all alignment parameters. Compared with knee-centered measurements, mLDFA increased by 1.52° (more varus), mMPTA decreased by 1.84° (more varus), and mLDTA decreased by 1.85° (more valgus) (all P < 0.001). These changes altered deformity classification, with femora classified as varus increasing from 4 to 10 and tibiae from 8 to 13. Conclusion: Using a lateral weight-bearing point for deformity analysis produces predictable changes in alignment measurements that frequently alter deformity classification. This approach may reveal occult femoral deformities underestimated by traditional methods and may provide a more biomechanically relevant framework for osteotomy planning.