Miguel Gonzalez-Andrades

Dr. Miguel Gonzalez-Andrades


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 June 2021 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
MIMohammad Mirazul Islam
Mohammad Mirazul Islam
DADina Abusamra
Dina Abusamra
ACAlexandru Chivu
Alexandru Chivu
Pablo ArgüesoPablo Argüeso
Pablo Argüeso
CDClaes Henrik Dohlman
Claes Henrik Dohlman
MGMiguel Gonzalez-Andrades
Miguel Gonzalez-Andrades
Collagen scaffolds, one of the most used biomaterials in corneal tissue engineering, are frequently crosslinked to improve mechanical properties, enzyme tolerance, and thermal stability. Crosslinkers such as 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride (EDC) are compatible with tissues but provide low crosslinking density and reduced mechanical properties. Conversely, crosslinkers such as glutaraldehyde (GTA) can generate mechanically more robust scaffolds; however, they can also induce greater toxicity. Herein, we evaluated the effectivity of double-crosslinking with both EDC and GTA together with the capability of sodium metabisulfite (SM) and sodium borohydride (SB) to neutralize the toxicity and restore biocompatibility after crosslinking. The EDC-crosslinked collagen scaffolds were treated with different concentrations of GTA. To neutralize the free unreacted aldehyde groups, scaffolds were treated with SM or SB. The chemistry involved in these reactions together with the mechanical and functional properties of the collagen scaffolds was evaluated. The viability of the cells grown on the scaffolds was studied using different corneal cell types. The effect of each type of scaffold treatment on human monocyte differentiation was evaluated. One-way ANOVA was used for statistical analysis. The addition of GTA as a double-crosslinking agent significantly improved the mechanical properties and enzymatic stability of the EDC crosslinked collagen scaffold. GTA decreased cell biocompatibility but this effect was reversed by treatment with SB or SM. These agents did not affect the mechanical properties, enzymatic stability, or transparency of the double-crosslinked scaffold. Contact of monocytes with the different scaffolds did not trigger their differentiation into activated macrophages. Our results demonstrate that GTA improves the mechanical properties of EDC crosslinked scaffolds in a dose-dependent manner, and that subsequent treatment with SB or SM partially restores biocompatibility. This novel manufacturing approach would facilitate the translation of collagen-based artificial corneas to the clinical setting.

21 May 2021 in Communications Biology
Verified
Journal Article
Open access
PDF file
FSFiona C. Simpson
Fiona C. Simpson
CMChristopher D. McTiernan
Christopher D. McTiernan
MIMohammad Mirazul Islam
Mohammad Mirazul Islam
OBOleksiy Buznyk
Oleksiy Buznyk
PLPhilip N. Lewis
Philip N. Lewis
MGMay Griffith
May Griffith
The long-term survival of biomaterial implants is often hampered by surgery-induced inflammation that can lead to graft failure. Considering that most corneas receiving grafts are either pathological or inflamed before implantation, the risk of rejection is heightened. Here, we show that bioengineered, fully synthetic, and robust corneal implants can be manufactured from a collagen analog (collagen-like peptide-polyethylene glycol hybrid, CLP-PEG) and inflammation-suppressing polymeric 2-methacryloyloxyethyl phosphorylcholine (MPC) when stabilized with the triazine-based crosslinker 4-(4,6-Dimethoxy-1,3,5-triazin-2-yl)-4-methylmorpholinium chloride. The resulting CLP-PEG-MPC implants led to reduced corneal swelling, haze, and neovascularization in comparison to CLP-PEG only implants when grafted into a mini-pig cornea alkali burn model of inflammation over 12 months. Implants incorporating MPC allowed for faster nerve regeneration and recovery of corneal sensation. CLP-PEG-MPC implants appear to be at a more advanced stage of regeneration than the CLP-PEG only implants, as evidenced by the presence of higher amounts of cornea-specific type V collagen, and a corresponding decrease in the presence of extracellular vesicles and exosomes in the corneal stroma, in keeping with the amounts present in healthy, unoperated corneas.

14 July 2020 in Scientific Reports
Verified
Journal Article
Open access
PDF file
AYA. Ashofteh Yazdi
A. Ashofteh Yazdi
JMJuan Melchor
Juan Melchor
JTJorge Torres
Jorge Torres
IFI. Faris
I. Faris
ACA. Callejas
A. Callejas
Guillermo RusGuillermo Rus
Guillermo Rus
The objective of this study was to evaluate which hyperelastic model could best describe the non-linear mechanical behavior of the cornea, in order to characterize the capability of the non-linear model parameters to discriminate structural changes in a damaged cornea. Porcine corneas were used, establishing two different groups: control (non-treated) and NaOH-treated (damaged) corneas (n = 8). NaOH causes a chemical burn to the corneal tissue, simulating a disease associated to structural damage of the stromal layer. Quasi-static uniaxial tensile tests were performed in nasal-temporal direction immediately after preparing corneal strips from the two groups. Three non-linear hyperelastic models (i.e. Hamilton-Zabolotskaya model, Ogden model and Mooney-Rivlin model) were fitted to the stress–strain curves obtained in the tensile tests and statistically compared. The corneas from the two groups showed a non-linear mechanical behavior that was best described by the Hamilton-Zabolotskaya model, obtaining the highest coefficient of determination (R2 > 0.95). Moreover, Hamilton-Zabolotskaya model showed the highest discriminative capability of the non-linear model parameter (Parameter A) for the tissue structural changes between the two sample groups (p = 0.0005). The present work determines the best hyperelastic model with the highest discriminative capability in description of the non-linear mechanical behavior of the cornea.

24 February 2021 in Macromolecular Bioscience
Verified
Journal Article
Closed access
PDF file
SSSina Sharifi
Sina Sharifi
MIMohammad Mirazul Islam
Mohammad Mirazul Islam
HSHannah Sharifi
Hannah Sharifi
RIRakibul Islam
Rakibul Islam
THTahmida N. Huq
Tahmida N. Huq
JCJames Chodosh
James Chodosh

27 March 2023 in Biomedicine & Pharmacotherapy
Verified
Journal Article
Open access
CGCarmen González-Gallardo
Carmen González-Gallardo
JMJuliana Martínez-Atienza
Juliana Martínez-Atienza
BMBeatriz Mataix
Beatriz Mataix
JMJosé Ignacio Muñoz-Ávila
José Ignacio Muñoz-Ávila
JMJ. Daniel Martínez-Rodríguez
J. Daniel Martínez-Rodríguez
RMRosario Mata
Rosario Mata
Corneal diseases are among the main causes of blindness, with approximately 4.6 and 23 million patients worldwide suffering from bilateral and unilateral corneal blindness, respectively. The standard treatment for severe corneal diseases is corneal transplantation. However, relevant disadvantages, particularly in high-risk conditions, have focused the attention on the search for alternatives. We report interim findings of a phase I-II clinical study evaluating the safety and preliminary efficacy of a tissue-engineered corneal substitute composed of a nanostructured fibrin-agarose biocompatible scaffold combined with allogeneic corneal epithelial and stromal cells (NANOULCOR). 5 subjects (5 eyes) suffering from trophic corneal ulcers refractory to conventional treatments, who combined stromal degradation or fibrosis and limbal stem cell deficiency, were included and treated with this allogeneic anterior corneal substitute. The implant completely covered the corneal surface, and ocular surface inflammation decreased following surgery. Only four adverse reactions were registered, and none of them were severe. No detachment, ulcer relapse nor surgical re-interventions were registered after 2 years of follow-up. No signs of graft rejection, local infection or corneal neovascularization were observed either. Efficacy was measured as a significant postoperative improvement in terms of the eye complication grading scales. Anterior segment optical coherence tomography images revealed a more homogeneous and stable ocular surface, with complete scaffold degradation occurring within 3-12 weeks after surgery. Our findings suggest that the surgical application of this allogeneic anterior human corneal substitute is feasible and safe, showing partial efficacy in the restoration of the corneal surface.

30 March 2022 in Eye
Verified
Journal Article
Closed access
PDF file
RARoberto Anaya-Alaminos
Roberto Anaya-Alaminos
MRMarie Louise Roed Rasmussen
Marie Louise Roed Rasmussen
SFSimon S. M. Fung
Simon S. M. Fung
JPJelena Potic
Jelena Potic
MGMiguel Gonzalez-Andrades
Miguel Gonzalez-Andrades