Proper selection and application of interfacial friction factor correlations has a significant impact on prediction of key flow characteristics in gas–liquid two-phase flows. In this study, experimental investigation of gas–liquid flow in a vertical pipeline with internal diameter of 0.060 m is presented. Air and oil (with viscosities ranging from 100–200 mPa s) were used as gas and liquid phases, respectively. Superficial velocities of air ranging from 22.37 to 59.06 m/s and oil ranging from 0.05 to 0.16 m/s were used as a test matrix during the experimental campaign. The influence of estimates obtained from nine interfacial friction factor models on the accuracy of predicting pressure gradient, film thickness and gas void fraction was investigated by utilising a two-fluid model. Results obtained indicate that at liquid viscosity of 100 mPa s, the interfacial friction factor correlation proposed by Belt et al. (2009) performed best for pressure gradient prediction while the Moeck (1970) correlation provided the best prediction of pressure gradient at the liquid viscosity of 200 mPa s. In general, these results indicate that the two-fluid model can accurately predict the flow characteristics for liquid viscosities used in this study when appropriate interfacial friction factor correlations are implemented.
Gas injection is a frequently used method for artificial lift and flow regime rectification in offshore production and transportation flowlines. The flow behaviour in such flowlines is complex and a better understanding of flow characteristics, such as flow patterns, void fraction/hold up distributions and pressure gradient is always required for efficient and optimal design of downstream handling facilities. Injection method and location have been shown to strongly affect downstream fluid behaviour that can have important implications for pumping and downstream facility design, especially if the development length between pipeline and downstream facility is less than L/D = 50 as reported by many investigators. In this article, we provide the results of an experimental investigation into the effects of the gas injection position on the characteristics of the downstream upwards vertical gas flow using a vertical riser with an internal diameter of 52 mm and a length of 10.5 m. A horizontal 40-m-long section connected at the bottom provides options for riser base or horizontal flow line injection of gas. The flowline gas injection is performed 40 m upstream of the riser base. A 16 by 16 capacitance wire mesh sensor and a gamma densitometer were used to measure the gas-liquid phase cross-sectional distribution at the riser top. A detailed analysis of the flow characteristics is carried out based on the measurements. These include flow regimes, cross-sectional liquid holdup distributions and peaking patterns as well as analysis of the time series data. Our findings show that flow behaviours differences due to different gas injection locations were persisting after a development length of 180D in the riser. More specifically, core-peaking liquid holdup occurred at the lower gas injection rates through the flowline, while wall-peaking holdup profiles were established at the same flow conditions for riser base injection. Wall peaking was associated with dispersed bubbly flows and hence non-pulsating as against core-peaking was associated with Taylor bubbles and slug flows. Furthermore, it was found that the riser base injection generally produced lower holdups. It was noted that the circumferential injector used at the riser base promoted high void fraction and hence low liquid holdups. Due to the bubbly flow structure, the slip velocity is smaller than for larger cap bubbles and hence the void fraction is higher. The measurements and observations presented in the paper provides valuable knowledge on riser base/flowline gas introduction that can directly feed into the design of downstream facilities such as storage tanks, slug catchers and separators.