Kivanc Ararat

Dr. Kivanc Ararat


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2020 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
YAYasin Almalioglu
Yasin Almalioglu
KOKutsev Bengisu Ozyoruk
Kutsev Bengisu Ozyoruk
AGAbdulkadir Gokce
Abdulkadir Gokce
KIKagan Incetan
Kagan Incetan
GGGuliz Irem Gokceler
Guliz Irem Gokceler
MTMehmet Turan
Mehmet Turan
Although wireless capsule endoscopy is the preferred modality for diagnosis and assessment of small bowel diseases, the poor camera resolution is a substantial limitation for both subjective and automated diagnostics. Enhanced-resolution endoscopy has shown to improve adenoma detection rate for conventional endoscopy and is likely to do the same for capsule endoscopy. In this work, we propose and quantitatively validate a novel framework to learn a mapping from low-to-high-resolution endoscopic images. We combine conditional adversarial networks with a spatial attention block to improve the resolution by up to factors of 8×, 10×, 12×, respectively. Quantitative and qualitative studies demonstrate the superiority of EndoL2H over state-of-the-art deep super-resolution methods Deep Back-Projection Networks (DBPN), Deep Residual Channel Attention Networks (RCAN) and Super Resolution Generative Adversarial Network (SRGAN). Mean Opinion Score (MOS) tests were performed by 30 gastroenterologists qualitatively assess and confirm the clinical relevance of the approach. EndoL2H is generally applicable to any endoscopic capsule system and has the potential to improve diagnosis and better harness computational approaches for polyp detection and characterization. Our code and trained models are available at https://github.com/CapsuleEndoscope/EndoL2H.

3 May 2021 in Sensors
Verified
Journal Article
Open access
PDF file
SZSamuel Zeising
Samuel Zeising
KAKivanc Ararat
Kivanc Ararat
Angelika S. ThalmayerAngelika S. Thalmayer
Angelika S. Thalmayer
DADaisuke Anzai
Daisuke Anzai
Georg FischerGeorg Fischer
Georg Fischer
JKJens Kirchner
Jens Kirchner
Capsule endoscopy is a well-established diagnostic tool for the gastrointestinal tract. However, the reliable tracking of capsule endoscopes needs further investigation. Recently, the static magnetic differential method for the localization of capsule endoscopes has shown promising results. This method was experimentally validated by investigating the difference in the measured values of the geomagnetic flux density of a representative sensor pair. In the measurements, it was revealed that misalignment of the sensors and ferromagnetic material near the sensor pair had the most significant impact on the differential approach. Besides, a systematical simulation-based study was conducted. Herein, the position and alignment of all sensors of the localization system were randomly varied. Furthermore, root-mean-squared noise was added to the sensor measurements, and the influence of nearby ferromagnetic material was evaluated. Subsequently, non-idealities were applied simultaneously on the proposed localization system, and the entire system was rotated. The proposed method was significantly better than state-of-the-art geomagnetic compensation methods for the localization of capsule endoscopes with mean position and orientation errors of approximately 2 mm and 1°, respectively.

14 November 2020 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
SZSamuel Zeising
Samuel Zeising
KAKivanc Ararat
Kivanc Ararat
Angelika S. ThalmayerAngelika S. Thalmayer
Angelika S. Thalmayer
DADaisuke Anzai
Daisuke Anzai
Georg FischerGeorg Fischer
Georg Fischer
JKJens Kirchner
Jens Kirchner
Although capsule endoscopy is already used for diagnosis of the gastrointestinal tract, a method to precisely localize the capsules, important for accurate diagnosis, is lacking. Static magnetic localization is a promising solution for that purpose. In this paper, the simulation of a differential static magnetic localization system with dynamic geomagnetic compensation was optimized. First, a convergence-test for the position and orientation errors as a function of the dimension of the computational domain was conducted. Subsequently, the diameter-to-length ratio of a permanent magnet was varied and the corresponding position and orientation errors, as well as the mean magnetic flux density measured at the sensor positions, were compared. The results revealed that for a computational domain radius of 800 mm, the position and orientation errors converged to less than 0.1 mm and 0.1°, respectively. The position and orientation errors were also of that order, even with the smallest permanent magnet employed in the study. Furthermore, the mean magnetic flux density measured at the sensors of the proposed magnetic localization system would be detectable using state-of-the-art magnetometers. It is concluded that the differential localization method is also feasible for small permanent magnets, which is especially important considering the limited space within endoscopy capsules.

22 June 2020 in arXiv
Verified
Preprint
Open access
PDF file
YAYasin Almalioglu
Yasin Almalioglu
KOKutsev Bengisu Ozyoruk
Kutsev Bengisu Ozyoruk
AGAbdulkadir Gokce
Abdulkadir Gokce
KIKagan Incetan
Kagan Incetan
GGGuliz Irem Gokceler
Guliz Irem Gokceler
MTMehmet Turan
Mehmet Turan
Although wireless capsule endoscopy is the preferred modality for diagnosis and assessment of small bowel diseases, the poor camera resolution is a substantial limitation for both subjective and automated diagnostics. Enhanced-resolution endoscopy has shown to improve adenoma detection rate for conventional endoscopy and is likely to do the same for capsule endoscopy. In this work, we propose and quantitatively validate a novel framework to learn a mapping from low-to-high resolution endoscopic images. We combine conditional adversarial networks with a spatial attention block to improve the resolution by up to factors of 8x, 10x, 12x, respectively. Quantitative and qualitative studies performed demonstrate the superiority of EndoL2H over state-of-the-art deep super-resolution methods DBPN, RCAN and SRGAN. MOS tests performed by 30 gastroenterologists qualitatively assess and confirm the clinical relevance of the approach. EndoL2H is generally applicable to any endoscopic capsule system and has the potential to improve diagnosis and better harness computational approaches for polyp detection and characterization. Our code and trained models are available at https://github.com/CapsuleEndoscope/EndoL2H.