Daisuke Anzai

Prof. Daisuke Anzai

Nagoya Institute of Technology, Nagoya, Aichi, Japan
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
TSTakunori Shimazaki
Takunori Shimazaki
DADaisuke Anzai
Daisuke Anzai
KWKenta Watanabe
Kenta Watanabe
ANAtsushi Nakajima
Atsushi Nakajima
MFMitsuhiro Fukuda
Mitsuhiro Fukuda
SAShingo Ata
Shingo Ata
Recently, wet-bulb globe temperature (WBGT) has attracted a lot of attention as a useful index for measuring heat strokes even when core body temperature cannot be available for the prevention. However, because the WBGT is only valid in the vicinity of the WBGT meter, the actual ambient heat could be different even in the same room owing to ventilation, clothes, and body size, especially in hot specific occupational environments. To realize reliable heat stroke prevention in hot working places, we proposed a new personalized vital sign index, which is combined with several types of vital data, including the personalized heat strain temperature (pHST) index based on the temperature/humidity measurement to adjust the WBGT at the individual level. In this study, a wearable device was equipped with the proposed pHST meter, a heart rate monitor, and an accelerometer. Additionally, supervised machine learning based on the proposed personalized vital index was introduced to improve the prevention accuracy. Our developed system with the proposed vital sign index achieved a prevention accuracy of 85.2% in a hot occupational experiment in the summer season, where the true positive rate and true negative rate were 96.3% and 83.7%, respectively.

5 January 2018 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
JWJianqing Wang
Jianqing Wang
RNRyo Nakaya
Ryo Nakaya
KSKeisuke Sato
Keisuke Sato
DADaisuke Anzai
Daisuke Anzai
OFOsamu Fujiwara
Osamu Fujiwara
FAFujio Amemiya
Fujio Amemiya
In this study, we developed an immunity test system for wearable devices used for healthcare or assistance to people with disabilities. The immunity test system consists of a pseudo biosignal generator for generating various vital signals such as electrocardiogram or electromyography and a bioequivalent gel phantom for simulating a part of the human body. As an application to the electrostatic discharge (ESD) immunity test for a myoelectric artificial hand, we used the pseudo biosignal generator to generate various myoelectric signals and confirmed a high correlation between the generated and the real myoelectric signals. We then applied this system to the IEC61000-4-2 specified ESD test. Through a comparison between the ESD test results by using the immunity test system and the result for a real human body, we found a high similarity between them, which suggests that the proposed immunity test system is feasible for various immunity tests in wearable devices.

3 May 2021 in Sensors
Verified
Journal Article
Open access
PDF file
SZSamuel Zeising
Samuel Zeising
KAKivanc Ararat
Kivanc Ararat
Angelika S. ThalmayerAngelika S. Thalmayer
Angelika S. Thalmayer
DADaisuke Anzai
Daisuke Anzai
Georg FischerGeorg Fischer
Georg Fischer
JKJens Kirchner
Jens Kirchner
Capsule endoscopy is a well-established diagnostic tool for the gastrointestinal tract. However, the reliable tracking of capsule endoscopes needs further investigation. Recently, the static magnetic differential method for the localization of capsule endoscopes has shown promising results. This method was experimentally validated by investigating the difference in the measured values of the geomagnetic flux density of a representative sensor pair. In the measurements, it was revealed that misalignment of the sensors and ferromagnetic material near the sensor pair had the most significant impact on the differential approach. Besides, a systematical simulation-based study was conducted. Herein, the position and alignment of all sensors of the localization system were randomly varied. Furthermore, root-mean-squared noise was added to the sensor measurements, and the influence of nearby ferromagnetic material was evaluated. Subsequently, non-idealities were applied simultaneously on the proposed localization system, and the entire system was rotated. The proposed method was significantly better than state-of-the-art geomagnetic compensation methods for the localization of capsule endoscopes with mean position and orientation errors of approximately 2 mm and 1°, respectively.

13 December 2020 in Sensors
Verified
Journal Article
Open access
PDF file
MCMinghui Chen
Minghui Chen
JWJianqing Wang
Jianqing Wang
DADaisuke Anzai
Daisuke Anzai
Georg FischerGeorg Fischer
Georg Fischer
JKJens Kirchner
Jens Kirchner
Biopotential sensing technology with electrodes has a great future in medical treatment and human—machine interface, whereas comfort and longevity are two significant problems during usage. Noncontact electrode is a promising alternative to achieve more comfortable and long term biopotential signal recordings than contact electrode. However, it could pick up a significantly higher level of common-mode (CM) noise, which is hardly solved with passive filtering. The impedance imbalance at the electrode-body interface is a limiting factor of this problem, which reduces the common mode rejection ratio (CMRR) of the amplifier. In this work, we firstly present two novel CM noise reduction circuit designs. The circuit designs are based on electrode-body impedance imbalance cancellation. We perform circuit analysis and circuit simulations to explain the principles of the two circuits, both of which showed effectiveness in CM noise rejection. Secondly, we proposed a practical approach to detect and monitor the electrode-body impedance imbalance change. Compared with the conventional approach, it has certain advantages in interference immunity, and good linearity for capacitance. Lastly, we show experimental evaluation results on one of the designs we proposed. The results indicated the validity and feasibility of the approach.

1 August 2023 in APL Materials
Verified
Journal Article
Open access
PDF file
KTKairi Takimoto
Kairi Takimoto
HTHiroki Takeshita
Hiroki Takeshita
AFAshif Aminulloh Fathnan
Ashif Aminulloh Fathnan
DADaisuke Anzai
Daisuke Anzai
SSShinya Sugiura
Shinya Sugiura
HWHiroki Wakatsuchi
Hiroki Wakatsuchi
We present a new concept of metasurface filters to preferentially extract pulsed waveforms at a constant frequency from a complex superimposed input signal. This filtering capability is realized using circuit-based metasurfaces, denoted waveform-selective metasurfaces, that behave according to the pulse duration of the incident wave. Importantly, our metasurface filters overcome a long-lasting issue of eliminating unnecessary pulses under simultaneous incidence without relying on variables that are commonly used for modulation schemes, e.g., frequency, time, and spatial variation (angular dependence). Such simultaneous filtering is made possible by integrating several types of waveform-selective metasurface unit cells with delay lines and successive interference cancellation processes. Moreover, we show that our concept can be extended to incorporating broadband signals, additional pulses, and variables used for existing modulation schemes. Our study therefore provides a higher degree of freedom to control electromagnetic waves and phenomena with possible applications including wireless power transfer and communications.

14 November 2020 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
SZSamuel Zeising
Samuel Zeising
KAKivanc Ararat
Kivanc Ararat
Angelika S. ThalmayerAngelika S. Thalmayer
Angelika S. Thalmayer
DADaisuke Anzai
Daisuke Anzai
Georg FischerGeorg Fischer
Georg Fischer
JKJens Kirchner
Jens Kirchner
Although capsule endoscopy is already used for diagnosis of the gastrointestinal tract, a method to precisely localize the capsules, important for accurate diagnosis, is lacking. Static magnetic localization is a promising solution for that purpose. In this paper, the simulation of a differential static magnetic localization system with dynamic geomagnetic compensation was optimized. First, a convergence-test for the position and orientation errors as a function of the dimension of the computational domain was conducted. Subsequently, the diameter-to-length ratio of a permanent magnet was varied and the corresponding position and orientation errors, as well as the mean magnetic flux density measured at the sensor positions, were compared. The results revealed that for a computational domain radius of 800 mm, the position and orientation errors converged to less than 0.1 mm and 0.1°, respectively. The position and orientation errors were also of that order, even with the smallest permanent magnet employed in the study. Furthermore, the mean magnetic flux density measured at the sensors of the proposed magnetic localization system would be detectable using state-of-the-art magnetometers. It is concluded that the differential localization method is also feasible for small permanent magnets, which is especially important considering the limited space within endoscopy capsules.