Mohamed Lamine Bouknia

Dr. Mohamed Lamine Bouknia


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 February 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MSmosbah said
mosbah said
Chemseddine ZEBIRIChemseddine ZEBIRI
Chemseddine ZEBIRI
DSDjamel SAYAD
Djamel SAYAD
Issa ElferganiIssa Elfergani
Issa Elfergani
MBMohamed Lamine Bouknia
Mohamed Lamine Bouknia
Raed Abd-AlhameedRaed Abd-Alhameed
Raed Abd-Alhameed
In this paper, we present the design of a compact and highly sensitive microwave sensor based on a metamaterial complementary split-ring resonator (CSRR), for liquid characterization at microwave frequencies. The design consists of a two-port microstrip-fed rectangular patch resonating structure printed on a 20 × 28 mm2 Roger RO3035 substrate with a thickness of 0.75 mm, a relative permittivity of 3.5, and a loss tangent of 0.0015. A CSRR is etched on the ground plane for the purpose of sensor miniaturization. The investigated liquid sample is put in a capillary glass tube lying parallel to the surface of the sensor. The parallel placement of the liquid test tube makes the design twice as efficient as a normal one in terms of sensitivity and Q factor. By bending the proposed structure, further enhancements of the sensor design can be obtained. These changes result in a shift in the resonant frequency and Q factor of the sensor. Hence, we could improve the sensitivity 10-fold compared to the flat structure. Subsequently, two configurations of sensors were designed and tested using CST simulation software, validated using HFSS simulation software, and compared to structures available in the literature, obtaining good agreement. A prototype of the flat configuration was fabricated and experimentally tested. Simulation results were found to be in good agreement with the experiments. The proposed devices exhibit the advantage of exploring multiple rapid and easy measurements using different test tubes, making the measurement faster, easier, and more cost-effective; therefore, the proposed high-sensitivity sensors are ideal candidates for various sensing applications.

30 November 2023 in Electronics
Verified
Journal Article
Open access
PDF file
YTYamina Tighilt
Yamina Tighilt
CBChahrazed Bensid
Chahrazed Bensid
DSDjamel SAYAD
Djamel SAYAD
SMSamira Mekki
Samira Mekki
RAMI ZEGADIRAMI ZEGADI
RAMI ZEGADI
Chemseddine ZEBIRIChemseddine ZEBIRI
Chemseddine ZEBIRI
A new compact UWB multiple-input–multiple-output (MIMO) antenna is presented in this paper. The proposed antenna, with a compact size of 30 × 20 × 1.6 mm3, consists of a two-element microstrip line-fed pentagonal-shaped patch associated with a parasitic element and a partial ground plane. Three complementary split-ring resonator (CSRR) structures are integrated into the defected ground with the aims of reducing the mutual coupling and enhancing the bandwidth. A UWB impedance bandwidth is achieved covering the FCC band (3.1–10.6 GHz), corresponding to a reflection coefficient below −10 dB and a reduced mutual coupling below −22 dB. Additionally, acceptable limits of the diversity performance parameters are obtained. Furthermore, all the simulated outcomes of the suggested antenna are convenient for UWB-MIMO wireless applications. Measures carried out on the fabricated prototype of the antenna demonstrate good agreement between both the simulation and measurement results of the optimized two-port MIMO antenna.

16 October 2023 in Frequenz
Verified
Journal Article
Closed access
SMSamira Mekki
Samira Mekki
RAMI ZEGADIRAMI ZEGADI
RAMI ZEGADI
MSmosbah said
mosbah said
DSDjamel SAYAD
Djamel SAYAD
IEIssa Elfergani
Issa Elfergani
Chemseddine ZEBIRIChemseddine ZEBIRI
Chemseddine ZEBIRI
In the present work, a study of a metamaterial complementary split ring resonator (CSRR) microwave planar sensor for dielectric liquid characterization is carried out using HFSS software. The design consists in a CSRR-loaded two ports rectangular patch microstrip-fed grounded planar structure. The investigated liquid sample is put in a capillary glass tube lying parallel to the surface of the sensor. The liquid test tube is deposited horizontally parallel to the surface of the planar sensor. The advantage of the design lies on the fact that it allows different orientations and multiple size possibilities of the test tube. This makes it possible to explore different resonant frequencies in the 2.1 GHz frequency band. Moreover, an optimization study is carried out to achieve a high sensitivity and a high-quality factor of the proposed sensor. To better understand the operation and to further verify the feasibility of the equivalent circuit, a parallel RLC resonant circuit is used to obtain the desired Z parameter responses Z11, Z22, Z21. A T-shaped electrical model of the proposed sensing structure is established using Advanced Design System (ADS) software. This latter constitutes one of the principal novelties of this work, which has never been addressed so far.

29 April 2021 in Electronics
Verified
Journal Article
Open access
PDF file
MBMohamed Lamine Bouknia
Mohamed Lamine Bouknia
Chemseddine ZEBIRIChemseddine ZEBIRI
Chemseddine ZEBIRI
DSDjamel SAYAD
Djamel SAYAD
Issa ElferganiIssa Elfergani
Issa Elfergani
JRJonathan Rodriguez
Jonathan Rodriguez
Ernesto LimitiErnesto Limiti
Ernesto Limiti
The present work considers the investigation of the effects of both electrical and magnetic uniaxial anisotropies on the input impedance, resonant length, and fields distribution of a dipole printed on an anisotropic grounded substrate. In this study, the associated integral equation, based on the derivation of the Green’s functions in the spectral domain, is numerically solved employing the method of moments. In order to validate the computing method and the evaluated calculation code, numerical results are compared with available data in the literature treating particular cases of electrical uniaxial anisotropy; reasonable agreements are reported. Novel results of the magnetic uniaxial anisotropy effects on the input impedance and the evaluated electromagnetic field are presented and discussed. This work will serve as a stepping stone for further works for a better understanding of the electromagnetic field behavior in complex anisotropic and bi-anisotropic media.

13 June 2025 in Optical and Quantum Electronics
Verified
Journal Article
Closed access
PDF file
RAMI ZEGADIRAMI ZEGADI
RAMI ZEGADI
DSDjamel SAYAD
Djamel SAYAD
SMSamira Mekki
Samira Mekki
MBMohamed Lamine Bouknia
Mohamed Lamine Bouknia
YTYamina Tighilt
Yamina Tighilt
Chemseddine ZEBIRIChemseddine ZEBIRI
Chemseddine ZEBIRI

1 January 2024
Verified
Conference Paper
Open access
PDF file
RAMI ZEGADIRAMI ZEGADI
RAMI ZEGADI
MBMohamed Lamine Bouknia
Mohamed Lamine Bouknia
DSDjamel SAYAD
Djamel SAYAD
IEIssa Elfergani
Issa Elfergani
Atul Kumar VarshneyAtul Kumar Varshney
Atul Kumar Varshney
Chemseddine ZEBIRIChemseddine ZEBIRI
Chemseddine ZEBIRI
This paper introduces the design of a 2.45 GHz patch antenna specifically intended for biomedical applications. This compact microstrip-fed antenna comprises a planar radiating patch with a circular configuration, fabricated on a substrate made of polymer resin composite material, measuring 1.6 mm in thickness. To assess how human tissue affects the antenna system, a three-layer human model representing skin, fat, and muscle was meticulously created using CST Microwave Studio. In addition, this research aims to emphasize the suitability of the chosen polymer resin material substrate for examining the antenna's performance. The antenna's performance was assessed in two different scenarios: one in free space and the other using the human body model. In a freespace environment, the antenna resonated at an operational frequency of 2.39 GHz, delivering a noteworthy bandwidth of 610 MHz, spanning from 2.15 GHz to 2.76 GHz. When placed on the human body model, the antenna resonated at 2.4 GHz, demonstrating an even broader bandwidth extending over 1060 MHz, ranging from 2.09 GHz to 3.15 GHz. Remarkably, the antenna achieved a gain exceeding 4.2 dBi and maintained an efficiency exceeding 97% across the entire frequency spectrum. Simulation outcomes further revealed a substantial reduction in the Specific Absorption Rate (SAR) by more than 98%, equivalent to a SAR value of merely 0.024 W/kg. This substantial reduction underscores the antenna's potential for secure and efficient use in biomedical applications.