Objectives. The study aimed to investigate the psychosocial predictors of bruxism. The association of various psychosocial factors such as alexithymia, emotional processing, state and trait anxiety, and stress with awake bruxism was analysed.Methods. The study involved 52 volunteers diagnosed with awake bruxism. The toolkit that was used included the Toronto Alexithymia Scale (TAS-20), the Emotional Processing Scale (EPS), the Cohen Perceived Stress Scale (PSS-10), and the State- and Trait-Anxiety Inventory (STAI), with independent individual psychological diagnoses being made for every patient. The results were statistically analysed using IBM SPSS Statistics 24.Results. The obtained data clearly show that psychological traits—both permanent dispositions (e.g., state anxiety and alexithymia) and temporary states (e.g., trait anxiety, emotional processing deficits, and psychological stress)—are significant determinants of awake bruxism. The percentage of explained variance indicates the presence of other factors as well.Conclusions. Psychosocial factors such as state anxiety and trait anxiety, alexithymia, and perceived stress are as important as somatic causes in the occurrence and maintenance of awake bruxism. The profile of the obtained data suggests the possibility of preventing or minimizing the symptoms of awake bruxism through properly constructed psychoprophylactic interactions.
Objectives. The study aimed to compare the accuracy of different methods of data acquisition and data reconstruction and to assess their usefulness for 3D printing of tooth replicas. Methods. 3-dimensional models of molar and canine teeth obtain utilizing CBCT examination with different protocols, and optical scanning was compared with models derived from micro-computed (micro-CT) examination using Geomagic Studio Qualify software. A pairwise comparison of 3D models with analysis of standard deviation and the value of the mean distance of given surfaces was performed. Results. Standard deviation and the value of the mean distance were lowest for optical scanning followed by CBC in high and standard resolution in all tested protocols. Models, obtained with high-resolution CBCT protocols, of teeth in and outside of alveolar bone showed similar average distance parameters, but standard deviation parameter was significantly lower for models of teeth scanned outside of the socket. Good surface representation on all models was seen at relatively smooth areas while in areas of high changes in the geometry CBCT based models performed inferiorly to those obtained from an optical scanner. Conclusions. In case of teeth of noncomplicated texture, independently from a position (within or outside the alveolar socket), the high-resolution CBCT seems to be a sufficient method to obtain data for 3D printed tooth replica. Optical scanning performs better when a detailed replica is necessary.
Objective. The aim of the study based on CT images was to assess the age-related changes in maxillary sinus diameters in relation to diameters of the facial skeleton. Materials and Methods. The retrospective analysis of CT images of the head of 170 patients aged 0–18 years (85 females and 85 males) was performed. Specific orientation points (zy, zm, pr, ns, n, and P) were identified in every patient and the following distances were measured: zy-zy, maximum facial width; zm-zm, midfacial width; n-pr, upper facial height; ns-pr, alveolar facial height; and ns-P, distance not indicated in craniometry. Results. The maxillary sinuses of every patient were bilaterally measured in three planes. Three diameters were obtained: maximum transverse (horizontal) diameter called MSW, maximum vertical diameter called MSH, and maximum anteroposterior diameter (length) called MSL. In females, the correlation of MSW, MSH, and MSL and zy-zy, as well as n-pr distances, is very strong. Moreover, the significant correlation was found between all measurements of maxillary sinus and ns-pr as well as ns-P distances in females. The correlation between MSL and all measurements of midface as well as MSH and MSW and all measurements except ns-P is stronger in females than in males. In males, all measurements of maxillary sinus correlate with ns-P distance very strongly. Conclusions. The statistical analysis (correlation and determination coefficient) showed that all measurements of maxillary sinuses correlate with midface dimensions.
29 April 2021 in Advances in Clinical and Experimental Medicine
As ultrasonography provides objective parameters and values, it is a reliable method of examining the structure and dimensions of the masseter muscle. Although the method is well known, there is no standardization in clinical examination and data analysis yet. The study aimed to measure masseter muscle thickness in designated areas to establish the most repeatable and clinically applicable method of ultrasound examination, and to assess differences in measurements in designated areas for clinical purposes by devising the size-independent parameter. The size-independent parameter may potentially be more clinically applicable than distance records, which are affected by the size of the subject. An ultrasound examination of 124 masseter muscles was performed. Axial examination in 3 horizontal regions (lower, middle and upper) and coronal examination in 2 vertical regions (proximal and distal) was carried out. Masseter muscle thickness was measured in every designated area when relaxed (muscle at rest (RMT)) and with clenched teeth (contracted muscle (CMT)). A morphological independent functional index of thickness difference (FITD) was calculated. The study revealed very high statistical differences between RMT and CMT (p < 0.0001) in all designated areas but with location variations. Masseter muscle thickness significantly differed depending on the examined area and transducer projection. The ultrasound study showed that masseter muscle thickness significantly differs depending on the examined area. The authors emphasize the necessity to examine the masseter muscle in specified areas with both coronal and axial projections to achieve objective and repeatable examination. Notable clinical value is assigned to FITD, which is independent from the morphological dimensions of the muscle.
Objectives. Fractal analysis of the radiographic pattern of bone has been used to evaluate its quantitative properties. However, the relation between initial implant stability and quality of bone remains unclear. The objective of this study was to evaluate RFA values in relation to the fractal dimension of bone where the implant was inserted. Material and Methods. A total of 50 two-stage dental implants were placed in the maxilla and mandible of 32 patients. After implant placement, an implant stability quotient (ISQ) was measured in two perpendicular planes. On intraoral digital periapical radiographs, three 35x35 pixels’ regions of interest (ROIs) were chosen covering the bone adjacent to the neck (ROI 1), middle (ROI 2), and apical (ROI 3) part of the implant, respectively. For every ROI, a fractal dimension (FD) was calculated. A linear correlation, as well as a logistic regression analysis, was used to identify a possible relation between the ISQ and FD values for every ROI in the maxilla and mandible. Results. The ISQ and FD values were found to be correlated at ROI 1 for the maxilla. There was no linear correlation between ISQ and FD values in any of the three ROIs in the mandible. However, logistic regression analysis showed that in ROI 1 and ROI 3 the values of FD and ISQ are statistically important and may be used to express the difference between maxilla and mandible. Conclusion. The fractal dimension of alveolar bone measured from intraoral digital radiographs alone may be an insufficient parameter to determine initial implant stability.
The inferior alveolar canal (IAC) is a fundamental mandibular structure. It is important to conduct a precise pre-surgical evaluation of the IAC to prevent complications. Recently, the use of artificial intelligence (AI) has demonstrated potential as a valuable tool for dentists, particularly in the field of oral and maxillofacial radiology. The aim of the study was to compare the segmentation time and accuracy of AI-based IAC segmentation with semi-automatic segmentation performed by a specialist. Thirty individual IACs from 15 anonymized cone-beam computed tomography (CBCT) scans of patients with at least 1 lower third molar were collected from the database of Poznan University of Medical Sciences, Poland. The IACs were segmented by a trainee in the field of oral and maxillofacial radiology using a semi-automatic method and automatically by an AI-based platform (Diagnocat). The resulting segmentations were overlapped with the use of Geomagic Studio, reverse engineering software, and then subjected to a statistical analysis. The AI-based segmentation closely matched the semi-automatic method, with an average deviation of 0.275 ±0.475 mm between the overlapped segmentations. The mean segmentation time for the AI-based method (175.00 s) was similar to that of the semi-automatic method (175.67 s). The results of the study indicate that AI-based tools may offer a reliable approach for the segmentation of the IAC in the context of dental pre-surgical planning. However, further comprehensive studies are required to compare the methods and consider their limitations more comprehensively.